Luxalon Closed Ceiling 75/1509/225C Specification

Hunter Douglas Specifications: Metal Linear Closed.Supply and fix Luxalon Closed Ceiling System as manufactured by Hunter Douglas Architectural Products.1.2 DESCRIPTION OF THE SYSTEM

NOTE to SPECIFIER Certainteed ICON Composite Siding

Polyurethane Composite Siding.NOTE TO SPECIFIER CertainTeed ICON Composite Siding.This section is based on products manufactured by CertainTeed Corporation, which is located in.Tel: (800) 233-8990 (professional)

Nbs Specification Text

NBS SPECIFICATION TEXT.L20. DOORS SHUTTERS HATCHES.STEEL LPS LEVEL 4 SECURITY DOOR SPECIFICATION.Powershield offer a comprehensive range of pre-engineered general purpose personnel doorsets ex-stock or manufactured to suit your requirements, with exceptional

Polyvinyl Chloride (Pvc) Windows s1

POLYVINYL CHLORIDE (PVC) WINDOWS.Series/Model: OceanView Double Hung Window.1) APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification to the extent referenced. The publications are referred to in text by basic designation only.a) Code of Federal Regulations (CFR)

Section 019913 - General Requirements Engineered Work

GUIDE SPECIFICATION SECTION 230210-14.Revised 16 February 2016 General Requirements.SECTION 230210 - GENERAL REQUIREMENTS.RELATED DOCUMENTS.Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division01 Specification sections, apply to this section

NOTE to SPECIFIER Crane Revolving Doors Company a Division of DORMA Entrance Systems;

REVOLVING ENTRANCE DOORS.NOTE TO SPECIFIER Crane Revolving Doors Company a division of DORMA Entrance Systems; revolving door products.This section is based on the products of Crane Revolving Doors Company a division of DORMA Entrance Systems which is located at.924 Sherwood Drive

Phenolic (Hpl) Wall Panels

PHENOLIC (HPL) WALL PANELS.1.1 SECTION INCLUDES.NOTE TO SPECIFIER Delete any items below not required for project.A. The extent of the panel and installation system work is indicated on the drawings and in these specifications

Metal Plate Wall Panels

METAL PLATE WALL PANELS.1.01 SECTION INCLUDES.A. Metal plate panels for walls and soffits, with related flashings and accessory components.1. Wet-sealed barrier wall based system.2. Wall cladding, parapet coping, beam wraps, cornices, soffit, sills, border

Abbreviations for Use on Drawings

LEGEND OF ABBREVIATIONS.ARCHITECTURAL ARCH.APPROXIMATELY APPROX.BACK TO BACK B/B.BUILDING BLDG.CENTER LINE CL.CENTER TO CENTER C/C.CHECKERED PLATE CHKD PL.CONCRETE CONC.CONCRETE MASONRY UNIT CMU.CONNECTION CONN.CONSTRUCTION CONSTR

Feasibility Study Report

FEASIBILITY STUDY REPORT.MUNICIPALITY NAME HERE.MUNICIPALITY NAME HERE.MUNICIPALITY NAME Feasibility Study Report.Table of Contents.TABLE OF CONTENTS.Executive Summary.1.1 Feasibility Study Objectives.1.2 Report Contents.2.1 Regulatory Requirements.2.1.1 ACO/COA Requirements for Municipalities

Sally Holland Corporate Director Support Services

Dear Dean Kirby.Re: Freedom of Information Request - 05981.I am writing regarding your request for information, which was received on 27th June.In In that request you asked us for information as shown below

Wood Ultimate Sliding French Door, Wood Sliding Patio Door

1.1 Section Includes.A. Wood Ultimate Sliding French Door and frame complete with hardware, glazing, weather strip, insect screen, grilles-between-the-glass, simulated divided lite, ADL, interior shades, raised/flat panels, jamb extension, and standard

Action Plan for Uptegraff Transformer At

Action Plan for Uptegraff Transformer At

ACTION PLAN FOR UPTEGRAFF TRANSFORMER AT.ARECIBO OBSERVATORY - ARECIBO, PUERTO RICO.Customer: Arecibo Observatory, End of Road 625, Arecibo, Puerto Rico 00612.Attn: Dr. Michael Nolan.Office: 787.878.2612 ext. 212 Fax: 787.878.1861 e-mail

Gypsum Cement Underlayment s4

GYPSUM CEMENT UNDERLAYMENT.RECOMMENDED SPECIFICATION FOR THERMA-FLOORâ UNDERLAYMENT AS THE HEAT MASS FOR RADIANT FLOOR HEATING.A. This is the recommended specification for Therma-Floor Underlayment as the heat mass for radiant floor heating.1.02 SECTION INCLUDES.A. Therma-Floor gypsum

Request for Bids s10

REQUEST FOR BIDS.CITY OF LINDEN.LINDEN MILLS BUILDING HVAC UPGRADES.The City of Linden will receive sealed bids at the City Clerk s Office, 132 E. Broad St., P.O. Box 507, Linden, MI 48451, for upgrades to the HVAC system at the Linden Mills Building on Monday, October 30, 2017 at 10:00 a.m

To: All At&T Installation Suppliers s6

AT&T INSTALLATION REQUIREMENT CHANGE NOTIFICATION - ATT-TP-76300-209.TO: ALL AT&T INSTALLATION SUPPLIERS Date: 10-17-2013.EFFECTIVE DATE: 5 days from posted date or as per Supplier s Contract.Submitter s Name: John Messina.TP: TP76300 Subject: Grounding Action: Add Modification: Delete