SETTING OF THE WEIGHING SCALE

* TAREMODEboth key press & make ON the power switch *

Display shows PASSUD Release Both Key. ( Tare & Mode )

Display shows LtrdP0 then press MR key to adjust Single Zero & Double Zero Accuracy in Liter Mode.

Set 0 or 1 For Single Zero & Set 2 to 9 For Double Zero in Liter Mode.

Display shows L1 0 then press MRkeyto adjust Linearity of the scale between 0-9. (L1 2)

Then press TARE key

Display shows MF 0 Liter mode (MF 0)

1kg - Counting mode

2Check weight mode

3 to 9 Liter mode.

Press TARE Display show

DISS 0 weighing mode (DISS 0)

1Auto off (power saving mode)

Press TARE Display show

A-0 2 Press MR to adjust Auto Zero Count of the scale between 0-9 (A-0 2)

Press TARE Display show CAP-1 then press TARE and enter the capacity by pressing ( 20080 )

MR(increase) and M+(shift) keys.

Press TARE Display show

DP1 3, press MR key to enter the correct value of decimal point location. ( DP1 3 )

Press TARE Display show FD1, Press TARE once and then enter the first digit by MR and (FD1 2 )

M+ keys.

------

Press TARE Display show CAP-2 then press TARE and enter the capacity by pressing ( 20080 )

MR(increase) and M+(shift) keys.

Press TARE Display show

DP2 3, press MR key to enter the correct value of decimal point location. ( DP1 3 )

Press TARE Display show FD2, Press TARE once and then enter the first digit by MR and (FD2 2 )

M+ keys.

------

Press TARE Display show CAP-3 then press TARE and enter the capacity by pressing ( 2 0 0 8 0 )

MR(increase) and M+(shift) keys.

Press TARE Display show

DP3 3, press MR key to enter the correct value of decimal point location. ( DP3 3 )

Press TARE Display show FD3, Press TARE once and then enter the first digit by MR and (FD3 2 )

M+ keys.

------

Press TARE Display show LITD then press TARE and enter the Code 9.700by pressing

MR(increase) and M+(shift) keys. parameters. (for Liter Conversion) For 2ookg/Liter 9 . 700

Press TARE The scale will become to weight mode.

Internal ADC count.

Press MODE key before power on and display will show the internal ADC count.

FOR CALIBRATION PROCESSURE

The Scale should be in weighing mode. Put 25% weigh of the capacity on platter then HOLD MR key, the display will be blank, then press MODE key, the display will show

“PASSWORD”. Press MODE key again, then enter the weigh by MR and M+ keys.

Press T/Z after weight entry, the display will show the actual weight after a blink.

Load cell Connection in 5 pin Round Metal Connecter.

1 Red

2 Black

3 White

4 Green

5 NC.

Tare Zero Switch Connection

1Black ( Common GND)

2Red

3Orange

4Brown

5Yellow