Record Format Document

RT_S76_LAPSED_CONF_SMP_DETAILS

Copyright Xoserve 2014©, all rights reserved.

No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / Xoserve
Owner: / Xoserve
Version: / 5
Status: / For Approval
Date: / 14-Oct-2014

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
4 / Current Live Version
5 / 1154 / 14-Oct-2014 / 1-Oct-2015 / File issued for representation

Notes

Note 1
OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places
Note 2
All text fields will be enclosed in double quotes ("")

Record Type Definition

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE:S76
SUPPLY_METER_POINT
METER_POINT_REFERENCE / M / N / 10 / 0 / An unique identifier for the point at which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. NewSupply Meter PointReferences will only be created for new services or when a service is relayed to a different position.
CONTEXT: A meter point (Daily or Non-Daily Metered) which is part of the Supply Point covered by the Confirmation reference provided.
METER_LOCATION_CODE / M / N / 2 / 0 / A code representing the location of a meter.
VALUES: 00 - Unknown, 01 -Cellar, 02 - Under Stairs, 03 -Hall, 04 - Kitchen, 05 - Bathroom, 06 - Garage, 07 - Canteen, 08 -Cloakroom, 09 - Cupboard, 10 -Domestic Science, 11 - Front Door, 12 - Hall Cupboard, 13 – KitchenCupboard, 14 - Kitchen under Sink, 15 - Landing, 16 - Office, 17 -Office Cupboard, 18 - Outside WC, 19 - Pantry, 20 - Porch, 21 – PublicBar, 22 - Rear of Shop, 23 – SaloonBar, 24 - Shed, 25 - Shop Front, 26 - Shop Window, 27 – StaffRoom, 28 - Store Room, 29 -Toilet, 30 - Under Counter, 31 -Waiting Room, 32 - Meter Box(Outside), 98 – Other,99 - Outside.
METER_SERIAL_NUMBER / MO / T / 14 / 0 / The manufacturers meter serial number
CONTEXT: The serial number of the meter from which the meter read was taken.
The manufacturers meter serial number.This field is not currently populated where no meter is present.Following representation fromShippers, Transco are reviewing default value in this situation.
SMP_OBJECTION_INDICATOR / M / T / 1 / 0 / Indicates whether the Supply Meter Point is currently subject to an objection.
VALUES: Y or N
Total / 30

RT_S76_LAPSED_CONF_SMP_DETAILSPage 1 of 4Issue Date: 7-Oct-2014

Version:5 For ApprovalImplementationDate: 1-Oct-2015