Technology Phase Submission Requirements

It is imperative that the A/E / Technology Designer submit Technology Responses, in writing, to Construction Managers as quickly as possible, but no later than 2 weeks within receipt of the Technology Review Comments.

District: /

Transmittal Date

Project Name: / Design Based on OSDM Year
Project CM: /

Ref. Job #:

Technology Design Firm / Technology Designer
Technology Review Firm / Technology Reviewer
Prepared By: / Reviewed By:

Submission: OSFC D/D Submission OSFC C/D Submission

Action: Approve Submittal Conditional Approval - Enclosed comments

Reject Submittal – Refer to enclosed comments. Bold items require immediate attention.

General Comments – Drawings
DD PHASE SUBMISSION

ITEM NO. 1Preliminary list of all T drawings as per OSFC specifications. – CONFORMS /NONCONFORMS

ITEM NO. 2Technology consultant must coordinate with all other trades in order to ensure proper pathway sizes and locations. – CONFORMS /NONCONFORMS

ITEM NO. 3Preliminary floor plans indicating the locations of all technology outlets throughout the building, including, but not limited to: data, voice, video, sound, paging, security, speakers, access control, and wireless. – CONFORMS /NONCONFORMS

ITEM NO. 4Preliminary connectivity codes for each type of communication outlet to be installed. – CONFORMS /NONCONFORMS

ITEM NO. 5Riser diagrams of all technology systems. – CONFORMS /NONCONFORMS

ITEM NO. 6Outline specifications including acceptable manufacturers. – CONFORMS /NONCONFORMS

ITEM NO. 7Preliminary engineering of any outside plant work to be performed. – CONFORMS /NONCONFORMS

ITEM NO. 8Preliminary schematics of all technology systems showing connectivity schemes. – CONFORMS /NONCONFORMS

ITEM NO. 9Floor plans showing all technology pathways, including cable trays in hallways, and conduits in walls. – CONFORMS /NONCONFORMS

ITEM NO. 10Floor plans indicating the locations of all technology devices throughout the building, including, but not limited: Rack/cabinet layouts, wall-fields, layer-3 network switches, routers, transceivers, PBX, servers, security system, digital media management equipment, monitors, DVD players, patch panels, cross-connects, etc. – CONFORMS /NONCONFORMS

ITEM NO. 11CM’s estimate. – CONFORMS /NONCONFORMS

ITEM NO. 12WLAN Predictive Analysis Survey indicating Protocol, Through-put and Client Density for 2.4 GHz and 5.0 GHz. – CONFORMS /NONCONFORMS

CD PHASE SUBMISSION

ITEM NO. 1Detailed CM’s estimate. – CONFORMS /NONCONFORMS

ITEM NO. 2Detailed floor plans indicating the locations of all technology devices throughout the building, including, but not limited: Rack/cabinet layouts, wall-fields, layer-3 network switches, routers, transceivers, PBX, servers, security system, digital media management equipment, monitors, DVD players, patch panels, cross-connects, etc. – CONFORMS /NONCONFORMS

ITEM NO. 3Detailed connectivity codes for each type of communication outlet to be installed. – CONFORMS /NONCONFORMS

ITEM NO. 4Detailed riser diagrams of all technology systems. – CONFORMS /NONCONFORMS

ITEM NO. 5Detailed specifications including acceptable manufacturers. – CONFORMS /NONCONFORMS

ITEM NO. 6Detailed engineering of any outside plant and inter-building work to be performed. – CONFORMS /NONCONFORMS

ITEM NO. 7Detailed schematics of all technology showing the integration of all Technology systems. Schematics should include: component type, connecting cable type, transmission speed, circuit type, inter-/intra building connections, uplink connections, etc. – CONFORMS /NONCONFORMS

ITEM NO. 8Schematics shall show physical/logical connection between all integrated technology systems. – CONFORMS /NONCONFORMS

ITEM NO. 9Detailed floor plans indicating the locations of all technology outlets throughout the building, including, but not limited to: data, voice, video, sound, paging, security, speakers, access control, and wireless. – CONFORMS /NONCONFORMS

ITEM NO. 10System Training Requirements . – CONFORMS /NONCONFORMS

ITEM NO. 11Areas of concentrated technology equipment and telecommunication rooms, in particular, shall be enlarged from basic floor plan to not less than ¼” = 1’-0”. – CONFORMS /NONCONFORMS

ITEM NO. 12Sheet notes shall be applicable to each sheet standard notes and details shall be modified to specific conditions, non-applicable notes or details shall be deleted. – CONFORMS /NONCONFORMS

ITEM NO. 13Provide scalable rack and wall-field details that indicate equipment locations and wire management. – CONFORMS /NONCONFORMS

ITEM NO. 14UPDATED WLAN Predictive Analysis Survey indicating Protocol, Through-put and Client Density for 2.4 GHz and 5.0 GHz. – CONFORMS /NONCONFORMS

F299-06v0813Page 1 of 2