SECTION 13129

PREFABRICATED METAL BUILDINGS, SHELTERS AND PRESS BOXES

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2006 - 2011 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Austin Mohawk and Company, Inc.; Prefabricated and factory-built structures, shelters and press boxes.
.
This section is based on the products of Austin Mohawk and Company, Inc., which is located at:
2175 Beechgrove Place
Utica, NY 13501
Toll Free Tel: 800-765-3110
Tel: 315-793-3000
Fax: 315-793-9370
Email: request info ()
Web: www.austinmohawk.com
[ Click Here ] for additional information.
Austin Mohawk has spent more than 80 years building superior quality, prefabricated metal structures. Our product line-up includes pre-manufactured buildings, shelters, press boxes and metal canopies. Our custom built structures are modular, functional and aesthetically pleasing. Our metal canopies, bus shelters, and walkway covers are designed, fabricated, and shipped for on-site erection. We are known for our breadth of design options, depth of engineering and better than competitive lead times.
The Austin and Mohawk brands represent our promise of something different and better in terms of performance, quality, value and trust.

PART 1 GENERAL

1.1   SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

A.   Prefabricated steel buildings.

B.   Prefabricated aluminum buildings.

C.   Prefabricated aluminum shelters.

D.   Prefabricated steel shelters.

E.   Press boxes.

1.2   RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A.   Section 02870 - Bollards; metal, concrete and stone bollards.

B.   Section 03300 - Cast-In-Place Concrete; concrete pad, foundations and anchor bolts.

C.   Section 05500 - Metal Fabrications.

D.   Section 07900 - Joint Sealers.

E.   Section 08710 - Door Hardware.

F.   Division 15 - Plumbing; plumbing services and connections.

G.   Division 16 - Electrical; electrical power service and wiring connections.

1.3   REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A.   ASTM International (ASTM):

1.   ASTM A 123 - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products.

2.   ASTM A 513 - Standard Specification for Electric-Resistance-Welded Carbon And Alloy Steel Mechanical Tubing.

3.   ASTM A 653/A - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.

4.   ASTM A 1008/A - Standard Specification for Steel Bars, Carbon and Alloy, Cold- Finished.

5.   ASTM B 209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.

6.   ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.

7.   ASTM B 632/B 632M - Standard Specification For Aluminum-Alloy Rolled Tread Plate.

8.   ASTM C 578 - Standard Specification For Rigid, Cellular Polystyrene Thermal Insulation.

9.   ASTM C 1048 - Standard Specification for Heat-Treated Flat Glass - Kind Hs, Kind Ft Coated and Uncoated Glass.

B.   American Society of Civil Engineers (ASCE): ASCE 7 - Minimum Design Loads for Buildings and Other Structures

C.   APA - The Engineered Wood Association:

1.   PRP-108 - Performance Standards and Policies for Structural-Use Panels.

2.   PFS PRP-133 - Performance Standards and Policies for Structural-Use Panels.

D.   National Fire Protection Association (NFPA): NFPA 70 - National Electric Code.

E.   Underwriters Laboratories Inc. (UL): UL 752 - Standard for Bullet Resisting Equipment.

F.   American National Standards Institute (ANSI): ICC/ANSI A117.1 - Accessible and Useable Buildings and Facilities.

G.   National Institute of Justice (NIJ): Standard 0101.04 - Ballistic Resistance of Personal Body Armor.

1.4   DESIGN REQUIREMENTS

** NOTE TO SPECIFIER ** Edit as required to suit project requirements. Standard loads are specified below, consult with manufacturer for requirements that exceed those specified as follows.

A.   Provide factory built, prefabricated structures and shelters capable of withstanding the effects of gravity loads and the following loads and stresses within limits and under conditions indicated.

B.   Design Loads: Determine loads based on the following minimum requirements:

** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.

1.   Uniform pressure of 40 lbf/sq ft, acting inward or outward (standard).

2.   Uniform pressure as indicated on Drawings.

** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the one not required.

3.   Wind Load: Buildings; 120 mph (2000 IBC Exp. C). (standard).

4.   Wind Load: Shelters and Press Box; 90 mph. (standard).

5.   Wind Load: As indicated on Drawings.

** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the one not required.

6.   Snow Load: Buildings and Shelters; 40 lbf/sq ft. (standard).

7.   Snow Load: Press Box; 30 lbf/sq ft. (standard).

8.   Snow Load: As indicated on Drawings.

** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.

9.   Live Load: Press Box; when press box has a camera deck, meet the minimum live load applicable where press box will reside.

10.   Live Load: As indicated on Drawings.

** NOTE TO SPECIFIER ** Delete the following paragraph below if not relevant to this project.

C.   Energy Code: Provide factory built, prefabricated structures that meet energy code requirements for the state the structure will reside in.

D.   Seismic Performance: Provide factory built, prefabricated structures and shelters capable of withstanding the effects of earthquake motions determined according to:

1.   ASCE 7, "Minimum Design Loads for Buildings and Other Structures": Section 9, "Earthquake Loads".

E.   Thermal Movements: Provide factory built, prefabricated structures and shelters that allow for thermal movements resulting from the following maximum change (range) in ambient and surface temperatures by preventing buckling, opening of joints, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.

1.   Temperature Change (Range): 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

F.   Electrical Devices: Devices UL listed with wiring bearing UL classification and conforming to the current NEC.

** NOTE TO SPECIFIER ** Adherence to applicable state and local codes is the responsibility of the Owner. For modular buildings, several state codes have requirements for third party design approval and inspection for compliance and/or the provision of P.E. stamped Drawings. Verify the requirements for your jurisdiction. These costs, if applicable, vary significantly between states and are available from building manufacturer at additional cost. Typically modular buildings on Federal Reservations do not require State or Local approvals.
Metal shelters do not generally require design approval and inspection for compliance. Delete the following Performance Requirement paragraph if not required.

1.5   PERFORMANCE REQUIREMENTS

** NOTE TO SPECIFIER ** The following states generally require third party design approval and inspection for modular buildings unless the project is a US Government or Agency job. Alabama, Arizona, California, Colorado, Connecticut, Florida, Georgia, Idaho, Indiana, Iowa, Kentucky, Louisiana, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New Mexico, New York, Nevada, North Carolina, Ohio, Oregon, Pennsylvania (if building will be occupied by more than 4 people), Rhode Island, South Carolina, Tennessee, Texas, Virginia, Washington, Wisconsin.
If a professional engineers' stamp is required on the shop Drawings for metal buildings or shelters, please designate state. Delete if not required.

A.   Cooperate with regulatory agency or authority and provide data as requested by authority having jurisdiction.

** NOTE TO SPECIFIER ** Include the following paragraph if ADA compliance is required. Delete if not required. If ADA compliance required, edit materials portion of this specification to accommodated the following: Building must be a minimum of 5 foot 6 inches by 7 foot 6 inches to allow for a 60 inch diameter clear space, the swing or sliding door must be 36 inches to provide a minimum 32 inch clear opening, door hardware shall be push/pull or lever handle, and sales and service counters shall be a maximum of 36 inches above the finished floor. An ADA restroom is provided to the required dimensions and equipped as specified under Paragraph Restrooms, ADA of this Specification.

B.   Prefabricated structures and shelters specified herein shall be handicapped accessible in accordance with ICC/ANSI A117.1 and other state and local requirements as applicable.

1.6   SUBMITTALS

A.   Submit under provisions of Section 01300.

B.   Product Data: Manufacturer's data sheets on each product to be used, including:

1.   Construction details, material descriptions, dimensions of individual components and profiles, and finishes.

2.   Preparation instructions and recommendations.

3.   Storage and handling requirements and recommendations.

4.   Installation methods.

C.   Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

D.   Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

E.   Certificates: Product certificates signed by the manufacturer certifying material compliance with specified performance characteristics and criteria, and physical requirements.

F.   Warranty Documentation: For warranty as specified herein.

1.7   QUALITY ASSURANCE

A.   Manufacturer Qualifications: Company specializing in manufacturing prefabricated structures and shelters with a minimum documented experience of twenty years and with a quality assurance program utilizing an independent third party quality control firm with a 5-stage, 35 step, quality inspection for each system.

B.   Prefabricated Components: Comply with manufacturer's published literature for products meeting indicated design loads in accordance with state and local requirements as applicable.

C.   Preinstallation Meetings: Conduct meetings to verify project requirements, substrate conditions, utility connections, manufacturer's installation instructions, and warranty requirements. Comply with Division 1 requirements.

1.8   DELIVERY, STORAGE, AND HANDLING

A.   Store products in manufacturer's unopened packaging until ready for installation.

B.   Protect all components and accessories from corrosion, deformation, damage and deterioration when stored at job site. Keep materials free from dirt and foreign matter.

1.9   PROJECT CONDITIONS

A.   Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.10   WARRANTY

A.   Manufacturer's Warranties:

1.   Provide manufacturer's 1-year limited warranty on products of its manufacture to be free of leaks and defects in materials and workmanship from date of shipment.

2.   Provide the manufacturer's 5-year limited warranty on anodized aluminum surfaces against oxidation.

3.   Provide the manufacturer's 20-year limited warranty against peeling, flaking and chipping of prefinished deck and fascia when properly maintained

** NOTE TO SPECIFIER ** Delete the following paragraph if the stated accessory items are not required.

B.   Provide manufacturer's warrantees on all accessory items provided such as, but not limited to, air conditioning, lights, and heating units.

PART 2 PRODUCTS

2.1   MANUFACTURERS

A.   Acceptable Manufacturer: Austin Mohawk and Company, Inc., which is located at: 2175 Beechgrove Place; Utica, NY 13501; Toll Free Tel: 800-765-3110; Tel: 315-793-3000; Fax: 315-793-9370; Email: request info (); Web: www.austinmohawk.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product Options and substitutions.

B.   Substitutions: Not permitted.

C.   Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2   MATERIALS

** NOTE TO SPECIFIER ** Delete materials not required.

A.   Aluminum: Alloy and temper recommended by manufacturer for type of use and finish specified, and as follows:

1.   Sheet: ASTM B 209.

2.   Extruded Shapes: ASTM B 221.

** NOTE TO SPECIFIER ** Delete option for rolled tread plates if not required.

3.   Rolled Tread Plates: ASTM B 632/B 632M, Alloy 6061-T4.

4.   Rolled Tread Plates: ASTM B 632/B 632M, Alloy 6061-T6.

B.   Cold-Rolled Steel Sheet: ASTM A 1008/A, Commercial Steel (CS), Type B.

C.   Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A, commercial quality, G60 (Z180) coating designation; mill phosphatized.

D.   Aluminum Treadplates: 1/8-inch aluminum plate conforming to ASTM B 209.

E.   Steel Mechanical Tubing: ASTM A 513, welded steel mechanical tubing.

F.   Expanded Polystyrene (EPS) Cores: Minimum of .95 pcf complying with ASTM C-578 Type 1.

G.   Oriented Strand Boards (OSB): Standard Grade; minimum physical properties conforming to APA PRP-108.

H.   Clear Tempered Float Glass: ASTM C 1048, Kind FT, Condition A, Type I, Class 1, Quality q3.

I.   Ballistics-Resistant Glazing: Comply with requirements of UL 752 or NIJ as applicable.

J.   Anchorages: Anchor bolts, as specified in Section 03300.

** NOTE TO SPECIFIER ** Delete if not required.

2.3   PREFABRICATED STEEL BUILDINGS

A.   Prefabricated Steel Buildings: As manufactured by Austin Mohawk and Company, Inc.

** NOTE TO SPECIFIER ** Select the size required from the following paragraphs and delete those not required. The maximum shipping width for custom sizes is 16 feet (4877 mm).

1.   Size: 3 feet (914 mm) by 4 feet (1219 mm).

2.   Size: 4 feet (1219 mm) by 4 feet (1219 mm).

3.   Size: 4 feet (1219 mm) by 5 feet (1524 mm).

4.   Size: 4 feet (1219 mm) by 6 feet (1829 mm).

5.   Size: 4 feet (1219 mm) by 7 feet (2134 mm).

6.   Size: 4 feet (1219 mm) by 8 feet (2438 mm).

7.   Size: 4 feet (1219 mm) by 9 feet (2743 mm).

8.   Size: 4 feet (1219 mm) by 10 feet (3048 mm).

9.   Size: 5 feet (1524 mm) by 5 feet (1524 mm).

10.   Size: 5 feet (1524 mm) by 6 feet (1829 mm).

11.   Size: 5 feet (1524 mm) by 7 feet (2134 mm).

12.   Size: 5 feet (1524 mm) by 8 feet (2438 mm).

13.   Size: 5 feet (1524 mm) by 9 feet (2743 mm).

14.   Size: 5 feet (1524 mm) by 10 feet (3048 mm).