Diaphragm seal flanged type with flush membrane / sheet 4 of 6
Manufacturing AB: MIS part no.: SEAL DF
Manufacturing Baesweiler: MIS part no.: SEAL DF BAE / G3.DF/E
Manufacturing Armaturenbau
Process connection:
DN15 flange DN15 (AB type MDM 7510) [inadmissible for ANSI ranges; only admissible for DIN range PN16]
DN25 flange DN25 (AB type MDM 7510 / 7511) [inadmissible for ANSI ranges; only admissible for DIN range PN40]
DN40 flange DN40 (AB type MDM 7510) [inadmissible for ANSI ranges; only admissible for DIN range PN40]
DN50 flange DN50 (AB type MDM 7510) [inadmissible for ANSI ranges; inadmissible for DIN range PN16]
DN80 flange DN80 (AB type MDM 7510) [inadmissible for ANSI ranges; inadmissible for DIN range PN320 and PN400]
DN100 flange DN100 (AB type MDM 7510) [inadmissible for ANSI ranges; only admissible for DIN range PN16 and PN40]
10 1“ flange (AB type MDM 7521) [inadmissible for DIN ranges; inadmissible for ANSI range 900 LBS, 1500 LBS und 2500 LBS]
15 1 ½“ flange (AB type MDM 7520) [inadmissible for DIN ranges; inadmissible for ANSI range 900 LBS, 1500 LBS und 2500 LBS]
20 2“ flange (AB type MDM 7520) [inadmissible for DIN ranges; inadmissible for ANSI range 400 and 900 LBS]
30 3“ flange(AB type MDM 7520) [inadmissible for DIN ranges; inadmissible for ANSI range 400 LBS]
40 4“ flange (AB type MDM 7520) [inadmissible for DIN ranges; inadmissible for ANSI range 1500 LBS and 2500 LBS]
Execution:
DF diaphragm seal flange type with flush diaphragm
face according DIN (AB type MDM 7510 / 7511) or ANSI (AB type MDM 7520 / 7521)
Diaphragm material:
G Hastelloy B2
H Hastelloy C276 over complete sealing ledge
HT Hastelloy C276 coating PTFE
N Nickel
P K-Monel
S stainless steel 1.4435
T Teflon coated metallic diaphragm
TI Titan
U Tantalum
UR Uranus B6 (1.4539) over complete sealing ledge
W stainless steel 1.4435 gold plated
Flange material:
S stainless steel 1.4435
Instrument connection:
02T ¼ NPT female
04T ½ NPT female
26T G ¼ female
15T G ½ female
Range and engineering unit:
PN16 [inadmissible for ANSI process connection; only admissible for DIN process connection DN,15 DN80 and DN100]
PN40 [inadmissible for ANSI process connection]
PN64 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50 and DN80]
PN100 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50 and DN80]
PN160 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50 and DN80]
PN250 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50 and DN80]
PN320 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50]
PN400 [inadmissible for ANSI process connection; only admissible for DIN process connection DN50]
150 LBS [inadmissible for DIN process connection]
300 LBS [inadmissible for DIN process connection]
400 LBS [inadmissible for DIN process connection; only admissible for ANSI process connection 40]
600 LBS [inadmissible for DIN process connection]
900 LBS [inadmissible for DIN process connection; only admissible for ANSI process connection 30 and 40]
1500 LBS [inadmissible for DIN process connection; only admissible for ANSI process connection 20 and 30]
2500 LBS [inadmissible for DIN process connection; only admissible for ANSI process connection 20 and 30]
Facing:
RF raised face (DIN EN 1092-1, Form B1)
RTJ ring type joint
Filling liquid:
= no filling liquid
CF Halocarbon [direct mounted or with capillary]
CG Glycerin [inadmissible for capillary; inadmissible for compound and vacuum ranges]
CK Silicon 50 [direct mounted or capillary £ 10‘ (3 m)]
CP Neobee M-20 [direct mounted or with capillary]
EJ Silicon 3 [capillary > 10‘ (3 m)]
GQ Weißöl silicone free „BP Energol WM2“ [inadmissible for capillary > 10‘ (3 m)]
GZ almond oil sweet
HA Syltherm 800 [direct mounted or with capillary]
ATEX:
= standard
ATEX ATEX listed for gas and dust (only for zone 1 and 2)
Info from Reinhold Schwartz. Due to missing registrations currently not available. 14.02.2011
Cleaning:
= Standard (no data)
VZ cleaned silicone free product
Material certificates:
= standard (no data)
CD2 material report according DIN EN 10204/2.2
CD3 material certificate according DIN EN 10 204/3.1 for wetted parts
CD5 material certificate according NACE MR0175/ISO15156-2003 and NACE MR0103-2005
[only admissible with diaphragm material H or S in combination with process connection material S, maximum temperature 60 °C/140 °F]
MQ positive material certificate (PMI)
Other variations (in alphabetical order):
= standard (no data)
CD5 material certificate according NACE MR0175/ISO15156-2003 and NACE MR0103-2005
[only admissible with diaphragm material H or S in combination with process connection material S, maximum temperature 60 °C/140 °F]
DU Instrument welded to seal
MO mounted on accessory
NH stainless steel tag
G . . . current end number for special customer request (e.g. G001) [will only be specified by engineering]
Manufacturing Baesweiler
Process connection:
DIN flanges [inadmissible for ANSI ranges]
DN15 flange DN15 [minimum pressure range 10 bar] For future production. For detailed information ask Engineering.
DN25 flange DN25 [actual only admissible for DIN range PN10 to PN100 (PN2,5 and PN6 for future production); minimum pressure range 6 bar]
DN40 flange DN40 [actual only admissible for DIN range PN10 to PN100 (PN2,5 and PN6 for future production); minimum pressure range 4 bar]
DN50 flange DN50 [actual only admissible for DIN range PN10 to PN100 (PN2,5 and PN6 for future production); minimum pressure range 1 bar]
DN80 flange DN80 [actual only admissible for DIN range PN10 to PN100 (PN2,5 and PN6 for future production); minimum pressure range 1 bar]
DN100 flange DN100 [actual only admissible for DIN range PN25 to PN100 (PN2,5, PN6 and PN10 for future production); minimum pressure range 1 bar]
DN125 flange DN125 [actual only admissible for DIN range PN10 to PN100 (PN2,5 and PN6 for future production); minimum pressure range 1 bar]
ANSI flanges [inadmissible for DIN ranges]
10 1“ flange [only admissible for ANSI range 150 LBS to 2500 LBS; minimum pressure range 6 bar]
15 1 ½“ flange [only admissible for ANSI range 150 LBS to 2500 LBS; minimum pressure range 4 bar]
20 2“flange [only admissible for ANSI range 150 LBS to 2500 LBS; minimum pressure range 1 bar]
30 3“flange [only admissible for ANSI range 150 LBS to 2500 LBS; minimum pressure range 1 bar]
40 4“flange [only admissible for ANSI range 150 LBS to 2500 LBS; minimum pressure range 1 bar]
Execution:
DF diaphragm seal flange type with flush diaphragm
face according DIN
Diaphragm material:
code / material / remarks / actual possible variationsH / Hastelloy C276 / generally inadmissible for diaphragm diameter S / process connection DN25, DN40, DN50, DN80, 15, 20 and 30 with diaphragm diameter B,
process connection 10 with diaphragm diameter E
HH / Hastelloy C276, Halar coated / generally inadmissible for diaphragm diameter S and E / process connection DN25, DN40, DN50, 15, 20 and 30
HT / Hastelloy C276, Teflon coated
N / Nickel / generally inadmissible for diaphragm diameter S and E / For future production.
For detailed information ask Engineering.
P / K-Monel / Implementation is not planned.
For detailed information ask Engineering.
S / 1.4435 / generally inadmissible for diaphragm diameter B / process connection DN25, DN40, DN50, DN80, DN100, DN125, 10, 15, 20, 30 and 40 with diaphragm diameter S,
process connection DN25, DN40, 10 and 15 with diaphragm diameter E
SG / 1.4435, gold plated / generally inadmissible for diaphragm diameter B and E / process connection DN25, DN40, DN50, DN80, DN100, DN125,10, 15, 20 30 and 40
ST / 1.4435, Teflon coated
TI / Titanium / generally inadmissible for diaphragm diameter E / For future production.
For detailed information ask Engineering.
U / Tantalum / process connection DN25, DN40, DN50, DN80, 10, 15, 20 und 30 with diaphragm diameter B
Diaphragm diameter:
S small diameter (dM) [inadmissible for diaphragm material H, HH, HT, P and TI]
B big diameter (d4) [inadmissible for diaphragm material S]
E enlarged diameter (d50 mm for process connection 10, d57 mm for process connection 15)
[only admissible for diaphragm material S in combination with process connection 10 and 15 and for diaphragm material H in combination with process
connection 10]
Flange material:
S stainless steel 1.4435
Instrument connection:
02T ¼ NPT female
04T ½ NPT female
26T G ¼ female
15T G ½ female
Range and engineering unit:
DIN ranges [inadmissible for ANSI flanges]
PN2,5 For future production. For detailed information ask Engineering.
PN6 For future production. For detailed information ask Engineering.
PN10
PN16
PN25
PN40
PN63
PN100
ANSI ranges [inadmissible for DIN flanges]
150 LBS
300 LBS
400 LBS
600 LBS
900 LBS
1500 LBS
2500 LBS
Facing:
RF raised face (DIN EN 1092-1, Form B1)
RTJ ring joint (according ANSI B 16.5) [only admissible for diaphragm material S in combination with diaphragm diameter S]
Filling liquid:
= no filling liquid
CF Halocarbon [direct mounted or with capillary]
CG Glycerin [inadmissible for capillary; inadmissible for compound and vacuum ranges]
Not longer available. For more information please ask R. Schwartz. 25.02.2010
CK Silicon 50 [direct mounted or capillary £ 10‘ (3 m)]
CP Neobee M-20 [direct mounted or with capillary]
EJ Silicon 3 [capillary > 10‘ (3 m)]
GQ Weißöl silicone free „BP Energol WM2“ [inadmissible for capillary > 10‘ (3 m)]
GZ almond oil sweet
HA Syltherm 800 [direct mounted or with capillary]
ATEX:
= standard
ATEX ATEX listed for gas and dust for further production. For detailed information ask Engineering
Cleaning:
= Standard (no data)
VZ cleaned silicone free product
X6W cleaned “free of oil and grease” (no Oxygen service)
Material certificates:
= standard (no data)
CD2 material report according DIN EN 10204/2.2
CD3 material certificate according DIN EN 10 204/3.1 for wetted parts
CD5 material certificate according NACE MR0175/ISO15156 & corrigendum 1 & 2 September 2005
[only admissible with diaphragm material H or U in combination with flange material H]
material certificate according NACE MR0175/ISO15156-2003 and NACE MR0103-2005
[only admissible with diaphragm material H or S in combination with flange material S, maximum temperature 60 °C/140 °F]
MQ positive material certificate (PMI) [only admissible for process connection; inadmissible for diaphragm/capsule]
CD2=CD5 combination of CD2 and CD5
CD3=CD5 combination of CD3 and CD5
CD3=CD5=MQ combination of CD3 and CD5 and MQ
Other variations (in alphabetical order):
= standard (no data)
MO mounted on accessory
NH stainless steel tag
G . . . current end number for special customer request (e.g. G001) [will only be specified by engineering]
Edition/revision / A / B / C / temporaryDate / 11.02.2004 / 06.04.2005 / 23.02.2006 / 02.05.2007 / 18.05.2011
EDV: Seal DF englisch.doc