Frameless Glass Instructions

Door and Panel

Step 1

From the opposite wall of the door and return panel measure

880mm and make a mark. This is the outside measurement

for your wall channel. Plumb this mark up the wall to give

you the outside mark for your wall channel.

Step 2

Mark and drill 2 holes in the wall channels lining up the grout

Lines were possible. The top hole should be within 100mm of

the top of the channel and the second should be within 500mm.

Please use silicone in the screw before fixing.

Step 3

Measure 880mm off the return panel wall and place a mark.

Then measure from the front edge of the wall channel to this mark.

This now gives you your floor channel measurement.

Cut the floor channel ensuring the correct 45 is on the correct end.

Step 4

Cut 2x 5mm thick packers from the rubber blocks supplied and

place in the channel to support the glass.

Note: you can adjust the thickness of the packers to raise or lower

the front edge to plumb the glass.

Step5

Installing the glass into the channels

Run silicone along the inside of the inner edge of the channel and

Install the glass. Place the wedges supplied on the outside of the glass

to push glass back against the silicone.

Clean of any excess silicone and leave for 12hrs.

Step 6

Measure 605mm from return Glass Panel, place a mark.

Then measure from outside of door return channel to this mark and cut

floor channel for door hinge panel and silicone in place.

Step 7

Repeat step 4 & 5 with the door return panel and leave for 12 hrs

Step 8

Sit in place top support panel which is supplied with the provided clips.

Plumb return panel and secure by tightening the clips

Step 9

Fit hinges to the hinge panel and tighten.

Step 10

Fit Handle to door.

Step 11

Fit door panel flush with top of hinge panel.

Allow a 2.5mm gap either side of the door.

Step 12

Remove wedges from outside and hinge panels

and seal with silicone.

Step 13

Run a bead of silicone down the outside of the wall and base channels.

This seals the channel to the tiles.

Please Note; these instructions are written to suit level floor and wall situation. Measurements will vary if wall and floor are not level.

Frameless Glass 1200 x 2000 x 12mm Walk-In Panel Installation

Step 1

Measure off the opposite wall of where you wish to install your 1200 x 2000 x 12 mm panel.

Plumb this mark up the wall to give you the outside mark of your wall channel.

Step 2

Mark and drill 2 holes in the wall channels lining up the grout

Lines were possible. The top hole should be within 100mm of

the top of the channel and the second should be within 500mm.

Please use silicone in the screw before fixing.

Step 3

Measure 1190mm off the return panel wall and place a mark.

Then measure from the front edge of the wall channel to this mark.

This now gives you your floor channel measurement.

Cut the floor channel ensuring the correct 45 is on the correct end.

Step 4

Cut 4x 5mm thick packers from the rubber blocks supplied and

place in the channel to support the glass.

Note: you can adjust the thickness of the packers to raise or lower

the front edge to plumb the glass.

Step5

Installing the glass into the channels

Run silicone along the inside of the inner edge of the channel and

Install the glass. Place the wedges supplied on the outside of the glass

to push glass back against the silicone.

Clean of any excess silicone and leave for 12hrs.

Step 12

Remove wedges from outside panels

and seal with silicone.

Step 13

Run a bead of silicone down the outside of the wall and floor channel.

This seals the channel to the tiles.

Please Note; these instructions are written to suit level floor and wall situation. Measurements will vary if wall and floor are not level.