CANARIIS CORPORATIONpage 2.23 VS*

Form FS020 Rev. 11FEB/11

VARIABLE SPEED BOOSTER SYSTEM DATA SHEET

JOB NAMEDATE

LOCATION

ENGINEER

CONTRACTOR

DISTRIBUTOR

SYSTEM INFORMATIONSYSTEM MODEL NO.

SYSTEM CAPACITYGPM

SYSTEM PRESSUREPSIG

MINIMUM SUCTION PRESSUREPSIG

MAXIMUM SUCTION PRESSUREPSIG

SYSTEM DIFFERENTIAL PRESSUREPSI

SYSTEM POWERVOLTSPHASEHERTZ

PUMP INFORMATIONPUMP NO. PUMP NO. PUMP NO.

PUMP TYPE

PUMP SIZE

VARIABLE / CONSTANT SPEED

MOTOR HP / FLA

MOTOR ENCLOSURE

DESIGN RPM

DUTY POINTGPM

TDH

PRV OR CHECK VALVE SIZE

PUMP SHUTOFF PSIG

MAX WORKING PRESS PSIG

MAX. WORKING PRESSURE IS THE TOTAL OF THE MAXIMUM SUCTION PRESSURE PLUS PUMP SHUT OFF HEAD AT MAX. SPEED AND MUST NOT EXCEED THE ALLOWABLE WORKING PRESSURE OF THE COMPONENTS.

STANDARD SYSTEM FEATURESSYSTEM OPTIONS

 COMPLETELY PREFABRICATED TYPE "L" COPPER MANIFOLDS

 GALVANIZED MANIFOLDS304L STAINLESS STEEL MANIFOLDS

 INDIVIDUAL PUMP ISOLATION VALVESPRV’S IN PLACE OF CHECK VALVES

 CHECK VALVE ON EACH PUMP PUMP PRESSURE GAUGES

THERMAL PURGE VALVES

 SYSTEM AND SUCTION PRESSURE GAUGES

 FACTORY TEST

SYSTEM CONSTRUCTION

 MANIFOLD SIZE " CONNECTIONS GROOVED FLANGED

CONFIGURATION RIGHT HAND LEFT HANDCUSTOM

 SYSTEM DIMENSIONS AND DRY WEIGHTL "x W "x H "WT #

HYDRO-PNEUMATIC TANKTANK LOCATION

 MODEL FX300V 80 GALLONS 150# ADJACENT TO SYSTEM

 MODEL FX500V 132 GALLONS 150# ON PUMP SKID

 MODEL FX750V 198 GALLONS 150# REMOTE MOUNTED

 MODEL FXA400 106 GALLONS 125# ASME

 MODEL FXA500 132 GALLONS 125# ASMEFOR UL LISTING TANK ON PUMP SKID MUST BE ASME

 MODEL FXA600 158 GALLONS 125# ASME

 MODEL FXA800 211 GALLONS 125# ASME TANK CONNECTED PER PAGE

 MODEL FXA700 185 GALLONS 200# ASME TANK STORAGE CAPACITY GAL.

*NOTE: ALSO PAGE 9.60.05 OF I.O.& M. MANUAL

PUMP OPERATING AND SEQUENCE CONTROLSPUMP SEQUENCE

 INTERMITTENT LEAD PUMP OPERATIONtoGPMPUMP

 CONTINUOUS RUN LEAD PUMPtoGPMPUMPS

SUCTION & DISCHARGE PRESSURE SENSORStoGPMPUMPS

FLOW SENSOR(REMOTE MOUNTED)toGPMPUMPS

VARIABLE FREQUENCY DRIVES

MANUFACTURER / MODELQUANTITY

 NEMA 1 ENCLOSURE NEMA 12 ENCLOSURE NEMA 3R ENCLOSURE

 FULL SPEED ELECTRICAL BYPASS (MANUAL)

STANDARD CONTROL PANEL FEATURES

 UL LISTED ENCLOSED INDUSTRIAL CONTROL PANEL

 NEMA 1 ENCLOSURE

 INDIVIDUAL DISCONNECTS WITH EXTERNAL HANDLES

 FUSE BLOCKS WITH FUSES

 CONTROL POWER (ON-OFF) SWITCH AND LIGHT

 PROGRAMMABLE LOGIC CONTROLLER (PLC)

 PUMP RUNNING LIGHTS

 H/O/A SELECTOR SWITCHES

 115 VOLT FUSED CONTROL CIRCUIT TRANSFORMER

 PUMP MINIMUM RUN TIMING

 AUTO ALTERNATE EQUAL PUMPS

 MOUNTED AND WIRED ON SKID

 PUMP OPERATING AND SEQUENCE CONTROLS

 LOW SUCTION PRESSURE ALARM ANDSHUTDOWN WITH AUTO RESET ANDINDICATION

 LOW SYSTEM PRESSURE ALARM WITH MANUAL RESET ANDINDICATION

 HIGH SYSTEM PRESSURE ALARM ANDSHUTDOWN WITH MANUAL RESET ANDINDICATION

 PUMP RUNTIME INDICATION

CONTROL PANEL OPTIONS

 NEMA 12 ENCLOSURE NEMA 3R ENCLOSURE NEMA 4 ENCLOSURE

 LOW SUCTION LEVEL ALARM ANDSHUTDOWN WITH AUTO RESET AND INDICATION – (SIGNAL BY OTHERS)

 HIGH SUCTION PRESSURE SHUTDOWN WITH AUTO RESET ANDINDICATION

 AUDIBLE ALARM WITH SILENCE PUSH BUTTON

 24 HOUR TIME CLOCK - ALTERNATE EQUAL PUMPS

 7 DAY TIME CLOCK FOR CONTINUOUS SYSTEM OPERATION

 FLOW SWITCH TO LIMIT LEAD PUMP ON-OFF CYCLING

 REMOTE ALARM PANEL WITH SILENCE PUSH BUTTON AND LIGHT

 AUXILIARY RELAY ALARM CONTACTS

 AUXILIARY RELAY PUMP STATUS CONTACTS

 LOCKABLE ENCLOSURE

 LIGHTNING ARRESTER

 EMERGENCY POWER ALARM TO PREVENT LAG PUMP(S) OPERATION (SIGNAL BY OTHERS)

 EMERGENCY POWER ALARM TO PREVENT SYSTEM OPERATION (SIGNAL BY OTHERS)

NOTES & COMMENTS:

NOTE: ALSO PAGE 9.60.06 & 9.60.07 OF I.O.& M. MANUAL

UL LISTED PACKAGED PUMPING SYSTEMS