Atkar
Au.diLuxdraftspecification1.3
ThefollowingDraftSpecificationcontainssections
ofitalicisedtextwherethespecifiersinputisrequired.
Textidentifiedwithanasterisk*requiresthenon-applicable wordingtobestruckoutordeleted.Textcontaining‘……’ requiresthespecifiedinformationtobeinserted.
1.1General
1.2Scope
Materials listed below to be supplied andinstalled
toallareasdetailedondrawings,orotherwisequantified.
1.3Qualifications
Installation shall comply with the relevant building codesusingapprovedfixingsandtheworkexecuted by competenttradesmen.
1.4Storage ofMaterials
All materials delivered to site shall be stored flatin
an enclosed shelter, providing protection from damage andexposuretotheelements.Damagedordeteriorated material shall be immediately removed fromsite.
2.1Product
2.2Panels Alternative1
Ceilings/walls*shallbeAu.diLux/Au.diLuxIAB*perforated fibre cement sheeting by Atkar, telephone 03 97963333. Panels shall be Atkar Product type …… and ……mm thick with square/ recessed edges,* allowing a nominal……mm unperforated margin to the sheet perimeter(optional).
2.3Insulation Alternative1
PanelsshallbesuppliedwithAtkarIntegratedAcoustic backing(IAB).
2.2Insulation Alternative2
Panels shall be installed with .……type and thickness backing insulation at the rear of each panel. Insulating materials to be laid across ……mm battens with fabric facingtensionedoverbattenstocreatea……mmdeep air gap/installed with insulation fitted between support membersandfabricfacingfittedoverentiresurfacearea*carefully installed to avoidcreasing.
2.3Execution
Wall studs, ceiling battens or furring channels shall be spacedat……mmcentresandpanelslaidatrightangles tothesemembers.Doublefurringchannelsorbattens
to be provided at sheet end joints for ceilingapplications.
Panelstobefixedwith……x……mmsize……type offastenerat……mmfixingcentresaroundperimeter ofpanelandat……mmfixingcentreswithinthebody
ofthepanel.Panelsshallbebuttedtogetherandinstalled tocreate……mmexpressedjoint/jointscovered
witha……x……mmsize……typetimbercoverstrip/ fitted into appropriately sized H-mould sheet holders/ joints taped, and flush jointed in accordance with manufacturer’s publishedspecifications.*
2.3 Completion
Upon completion of the installation, check that allpanels andcovermoulds(ifapplicable)aresecurelyfastened
to their framing members and all fixings are properly stoppedwithanapprovedfiller.Surfacetobeprepared toanapprovedstandardinreadinesstoreceivesurface treatment applied byothers.
©Copyright Atkar