1
Instrumental Analysis
1. Write Bragg’s Law
2.Write name of the two metals we commonly use as anode in home X-ray source.
3. How many primers are required during PCR based DNA sequencing using Sanger’s method?
- One b. Zero c. Two d.Four
4. During the manual method of DNA sequencing the primer is labelled by:
- Adding all four dNTPs in regular amount and DNA polymerase
- Adding all four dNTPs in regular amount of which one is radioactively labelled and DNA polymerase
- Adding all four dNTPs in limiting amount of which one is radioactively labelled and DNA polymerase
- Adding all four dNTPs in limiting amount and DNA polymerase
5. High throughput DNA sequencing using Sanger’s method was possible due to
improvement in the:
- Labelling and detection methodb. Fragment separation technique
c. DNA polymerase used and resulting strategies for generation of fragments
- All of the above
6. In the ABI Prism 310 machine the capillary is filled with:
- Polyacrylamide gel solution b. A liquid polymer
c. Agarose gel solution d. Sephadex beads
7. The novelties of the Solexa method of DNA sequencing are:
(a)Generation of millions of clusters of different DNA templates on a tiny solid surface
(b)Use of reversibly 3’ blocked deoxynucleotides
(c)Use of fluorescence labelled dideoxynucleotides (d) a and b both
8. A cation-exchanger chromatography column can be done at any pH? True False
9. At a constant pH, all unabsorbed fractions of a cation-exchanger will bind to an anion-exchanger. True False
10. Re-chromatography always yields better purification. True False
11. A gel filtration chromatography followed by a cation or anion-exchanger chromatography is a better sequence for purification of a protein than the reverse order.
True False
12. Resolution power of a gel filtration column is significant near or within its
Void volume Fractionation range Desalting zone
13. Can a lectin (carbohydrate binding protein) be separated using a Sephadex matrix (cross inked dextran) based on its molecular weight? Yes No
14.Binding of a material to hydroxyapatite column involves:
Adsorption phenomenon Absorption phenomenon
Non-specific binding Specific binding.
15. In reverse-phase HPLC, the column matrix is:
positively charged negatively charged Hydrophobic Hydrophilic.
16. Is there any restriction on the volume of sample to be applied to a cation or anion exchanger column? Yes No
17. For the detection of DNA fragmentation it is preferred to use
a)EI b)MALDI c)ESI d)APCI
18. How many peaks would you expect in the mass spectrum of 1-bromobutane and
what should be their intensity?
(a)3, 1:1:1 (b) 2, 2:1 (c) 2, 1:1 (d) 2, 3:1
19. If the observed mass of a biopolymer are m/z 671.584 & 638.078, then the actual
mass is
a)12730.968 b) 12741.096 c)12731.096 d)12740.096
20. Predict the double bond equivalent (D.B.E) of the molecule whose molecular formula is C11H16.
a) 5 b) 3 c) 4 d) 6
21. Predict the nature of the compound whose molecular weight is 121.
a)Ester b) Alcohol c) Amide d)Acid
- What should be the most abundant peak in the mass spectrum of 1-(4-methylphenyl)-ethanol?
- 126b. 121 c. 119 d. 110
- Define Precision frequency. What is the relationship between Precision frequency and Static Magnetic Field strength (B0)?
- What is Scalar coupling? Explain its effect on the observed NMR spectrum.
25. Circular dichroism is the difference in the absorption
(a) of incident and diffracted light (b) of incident and absorbed light
(c) left and right circularly polarized light (d) incident and scattered light
26. Circular dichroic spectral pattern is generally expressed in terms of
(a)wavelength versus optical density
(b)wavelength versus molar ellipticity
(c)wavelength versus refractive index
(d)wavelength versus absorbance
27. The CD spectrum of a DNA polynucleotide has a long wavelength negative band (inthe
280-300 nm) followed by positive band around 250 nm. The structure can be most likely
(a)alpha helix (b) left handed Z-form (c) beta sheet (d) right handed B-form
28. An alpha helical conformation of a protein is characterized in CD by the
(a)double minima at 222 and 208 bands
(b)negative and an equally positive band at 222 nm
(c)positive CD bands in the 200-230 nm region
(d)a negative band at 205 nm
29. In fluorescence spectroscopy external energy is supplied to the sample by means of
(a)UV/Vis light (b) Radio active decay (c)Fluorescent light (d)None of the above
30. In fluorescence spectroscopy the detector is placed at 90o to the incident light to get
better signal-to-noise ratio, when compared to the 180° geometry
(a)avoid external light
(b)to avoid reflection
(c) to avoid interference from diffracted light
(d)to avoid transmitted excitation light and stray light
31. Fluorescence polarization (anisotropy) gives information about
(a)shape, size and flexibility of the molecules
(b)molecular weight of the molecules
(c) location of the molecule
(d) concentration of the molecules in the solution
32. Fluorescence Resonance Energy Transfer only occurs when the two fluorophores are more or less within about
(a)anywhere beyond 1000 Ǻ (>0.1μm) (b) 200-1000 Ǻ (0.02-0.1μm)
(c) 500-1000 Ǻ (0.05-0.1μm) (d) 20-100Ǻ (0.002-0.01μm) of each other
33. The fluorescence spectrum of a protein has an emission maximum at 348 nm when excited at 280 nm. The fluorescence may be most likely from the
(a) phenylalanines (b) tyrosines (c) tryptophans (d) none of the above
34. Intracellular Ca2+ using Confocal Microscope can be measured by loading cells with which of the following dyes?
(a)Fluo 3AM (b) Fluo 3 (c) Rhodamine (d)Alexa Fluor 488
35. The amount of “out of focus light rays” into the detector of a confocal microscope will be increased if
(a)Pinhole is decreased (b)Pinhole is increased
(c) the wavelength of the excitation beam is increased (d)None of the above
36. The primary benefit of the confocal microscope over the conventional wide field microscope is
(a)The ability to control the depth of the field by confocal microscope
(b)Image is more clear in confocal microscope.
(c)The digitization is more easier by confocal microscope
(d)None of the above.
37. Name the suitable dye (s) for staining nucleus.
(a)Alexa Fluor 633 (b) DAPI (c) Propidium iodide (d) Both b and c
38. Confocal eliminates “out of focus information” by using which one of the following devices?
(a)Beam splitter (b) Pinhole (c) Mirror (d) Objective
39. The primary limiting factor for resolution in a light microscope is the:
a) quality of the lensesb) index of refractionc) wavelength of light
40.Which of the following is NOT true of electron microscopy (EM):
a) EM can be used to examine the movement of flagella
b) EM uses heavy metals as stains
c) Electrons replace light in the electron microscope
41. When biologists wish to study the internal ultra-structure of cells, they most likely would use:
a)a transmission electronic microscope
b)a light microscope
c)a scanning electron microscope
42. In its optical design, the transmission electron microscope is most like a(n):
a)atomic force microscope
b)compound light microscope
c)scanning electron microscope
43. Which instrument gives the most "3-dimensional-like" image?
a)Compound light microscope
b)Transmission electron microscope
c)Scanning electron microscope
44. How does the scanning electron microscope differ from the transmission electron microscope? It:
a)uses electromagnetic lenses
b)operates with a vacuum
c)maps images rather than optically projecting them
45. Define the role of isotype-matched control antibody in immunofluorescence staining.
46. Explain the principle of annexin V-FITC staining for measurement of apoptosis.
47. How can you distinguish apoptosis from necrosis in flow cytometry?
48. You would like to amplify a 1kb fragment using the Polymerase Chain Reaction. What is the expected number of copies of the fragment at the end of 20 cycles if
(i) two primers are used ______
(ii) one primer is used in the PCR ______
49. Specificity of a PCR can be increased using the technique ______PCR
50. Advantage of Sybr Green over ethidium bromide in real time PCR id due to one or more
of the following:
(a) Sybr Green and not ethidium bromide intercalates into double stranded DNA
(b) Sybr Green fluoresces with higher intensity than ethidium bromide when boundto
double stranded DNA
(c) Sybr Green fluoresces with higher intensity than ethidium bromide when bound
to single stranded DNA
(d) Sybr Green fluoresces with higher intensity than ethidium bromide whenbound to
double stranded and single stranded DNA