SECTION 07620

ROOF EDGE AND VENTILATION SYSTEMS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2012 - 2015 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Metal Era, Inc.; Roof edge and ventilation systems products.
.
This section is based on the products of Metal Era, Inc., which is located at:
1600 Airport Rd.
Waukesha, WI 53188
Toll Free Tel: 800-558-2162
Tel: 262-549-6900
Fax: 800-373-9156
Email:request info ()
Web:
[Click Here] for additional information.
We are a team dedicated to manufacturing quality products and finding solutions for the roofing industry. We are committed to listening to our customers and providing unsurpassed service and pledge to share our talents for mutual growth, prosperity and achievement in excellence.
For 30 years Metal-Era, Inc. has set out to fulfill this mission by representing the quality and service you expect from a commercial roof edge and roof ventilation manufacturer. You expect service that is unequaled in the industry, and you deserve a wide selection of engineered roof edge and roof ventilation solutions, designed to meet the roofing industry's strictest standards. These are the qualities Metal-Era offers you today.
Metal-Era's Roof Edge Solutions provides complete lines of fascia and coping products to meet a wide range of roof conditions and architectural requirements. These tested, warranted products are engineered and warranted to withstand some of the harshest wind conditions.

PART 1 GENERAL

1.1 SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

A. Metal Fascia.

B. Metal Coping.

C. Metal Gravel Stop,

D. Metal Drip Edge.

E. Metal Coping Cap.

F. Vented and Non-Vented Eave and Fascia.

G. Ridge Vent.

H. Ballast paver terminations.

I. Accessories.

1.2 RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A. Section 06150 - Wood Decking.

B. Section 06160 - Sheathing: Plywood and oriented strand board.

C. Section 06200 - Wood Trim.

D. Section 07220 - Roof and Deck Insulation: Roof board insulation.

E. Section 07310 - Roof Shingles.

F. Section 07320 - Roof Tiles.

G. Section 07410 - Metal Roof and Wall Panels: Preformed metal roofing.

H. Section 07500 - Membrane Roofing.

I. Section 07620 - Sheet Metal Flashing and Trim.

J. Section 07720 - Roof Accessories: Soffit vents, roof pavers, etc.

1.3 REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A. ANSI/SPRI ES-1 - Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems.

B. Florida Building Code, including the High Velocity Hurricane Zone.

C. Miami-Dade County NOA No. 03-0108.06.

D. Factory Mutual Research Corporation Approval Guide.

E. SPRI Single Ply Roofing Industry Standards.

1.4 SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data sheets on each product to be used, including:

1. Preparation instructions and recommendations.

2. Storage and handling requirements and recommendations.

3. Installation methods.

C. Shop Drawings: Show profiles, joining method, location of accessory items, anchorage and flashing details, adjacent construction interface, and dimensions.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

D. Selection Samples: For each finish product specified, two complete sets of color charts representing manufacturer's full range of available colors and patterns.

E. Verification Samples: For each finish product specified, two sample chips representing actual product, color, and patterns.

F. Manufacturer's Certificates: Certify products meet or exceed specified requirements.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing Products specified in this section with minimum twenty five years documented experience.

B. Installer Qualifications: Company specializing in the installation of products specified in this section with minimum five years documented experience.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1. Finish areas designated by Architect.

2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

3. Refinish mock-up area as required to produce acceptable work.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer's unopened packaging until ready for installation.

B. Store materials in a dry, protected, well-vented area.

C. Remove protective plastic surface film immediately before installation.

D. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.7 SEQUENCING

A. Ensure that information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.

B. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

C. Coordinate installation with roof membrane manufacturer's installation instructions.

1.8 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.9 WARRANTY

A. Provide the manufacturer's warranty specified under products for the roof edge system, when installed per manufacturer's instructions. Warranty will not exceed the life of the roof membrane on which the product was originally installed.

B. Provide a 30 year warranty for manufacturer approved 70 percent Kynar colors for the painted finish covering color fade, chalk, and film integrity.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Metal Era, Inc., which is located at: 1600 Airport Rd.; Waukesha, WI 53188; Toll Free Tel: 800-558-2162; Tel: 262-549-6900; Fax: 800-373-9156; Email:request info (); Web:

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

** NOTE TO SPECIFIER ** Edit the following paragraphs as required for the project requirements. Delete the paragraphs for the products not required.

2.2 ROOF EDGE PRODUCTS

A. Anchor-Tite Standard Fascia: Decorative metal fascia with continuous extruded aluminum bar.

1. Construction:

a. Fascia metal gauge:

** NOTE TO SPECIFIER ** Select one of the following metal paragraphs and delete the one not required. Note that 24 gauge galvanized steel is available unfinished only.

1) .040 inch (1 mm) thick formed aluminum.

2) 24 gauge galvanized steel.

b. Aluminum Finish:

** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.

1) Natural aluminum mill finish.

2) Clear anodized aluminum.

3) Black anodized Aluminum.

4) Dark Bronze anodized aluminum.

5) Extra Dark Bronze anodized aluminum.

6) Champagne anodized aluminum.

7) Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.

8) Custom Kynar-500 color as selected by the Architect.

c. Fascia: Standard 12 feet 0 inches (3.65 m) lengths.

d. Extruded bar: Shall be continuous 6063-T6 alloy aluminum at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.

1) Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.

2) Fasteners: 2 inch (51 mm) stainless steel with driver.

** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.

2. Fully Adhered or Mechanically Attached Single-Ply Version

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AF-55 -5-1/2 inch (139.7 mm) face height).

1) AF-40.

2) AF-55.

3) AF-70.

4) AF-85.

b. Performance:

1) Lifetime, 215 mph Wind Warranty.

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft2to comply with the International Building Code.

3) Factory Mutual 1-645 approved for wind up lift protection.

4) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

3. Built-Up or Modified Version

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AMF-55 -5-1/2 inch face height).

1) AFM-55.

2) AFM-70

3) AFM-85.

b. Performance:

1) Lifetime, 215 mph Wind Warranty.

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft2to comply with the International Building Code.

3) Factory Mutual 1-645 approved for wind up lift protection.

4) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

B. Anchor-Tite HG Fascia: Two-part assembly consisting of a continuous extruded aluminum bar and exterior fascia with fasteners.

1. Construction:

a. Fascia Metal:

** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.

1) .050 inch (1.27 mm) thick-formed aluminum.

2) .063 inch (1.6 mm) thick-formed aluminum.

b. Finish:

** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.

1) Natural aluminum mill finish.

2) Clear anodized aluminum.

3) Black anodized Aluminum.

4) Dark Bronze anodized aluminum.

5) Extra Dark Bronze anodized aluminum.

6) Champagne anodized aluminum.

7) Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.

8) Custom Kynar-500 color as selected by the Architect.

c. Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.

d. Extruded bar: Shall be continuous 6063-T6 alloy aluminum at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.

1) Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.

2) Fasteners: 2 inch (51 mm) stainless steel with driver.

** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.

2. Fully Adhered or Mechanically Attached Single-Ply Version:

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. HG-AF--55 -5-1/2 inch (139.7 mm) face height).

1) HG-AF-55.

2) HG-AF-70.

b. Performance:

1) Lifetime, 215 mph Wind Warranty.

2) Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

3. Built-Up or Modified Version:

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AF-55 -5-1/2 inch (139.7 mm) face height).

1) HG-AFM -40.

2) HG-AFM-55.

3) HG-AFM-70.

b. Performance:

1) Lifetime, 215 mph Wind Warranty.

2) Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.

C. Anchor-Tite Extended Fascia: A three-part assembly consisting of a continuous extruded aluminum bar, exterior fascia and continuous formed galvanized steel cleat with fasteners.

1. Construction:

a. Fascia Metal:

** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.

1) .050 inch (1.27 mm) thick-formed aluminum.

2) .063 inch (1.6 mm) thick-formed aluminum.

b. Finish:

** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.

1) Natural aluminum mill finish.

2) Clear anodized aluminum.

3) Black anodized Aluminum.

4) Dark Bronze anodized aluminum.

5) Extra Dark Bronze anodized aluminum.

6) Champagne anodized aluminum.

7) Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.

8) Custom Kynar-500 color as selected by the Architect.

c. Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.

d. Extruded Bar: Shall be continuous 6063-T6 alloy aluminum in 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.

1) Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.

2) Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.

e. Anchor Bar Cleat: Standard 12 feet 0 inches (3.65 m) lengths of commercial type 20 gauge G-90 galvanized steel with pre-punched holes.

** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.

2. Fully Adhered or Mechanically Attached Single-Ply Version:

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEF-85 -8-1/2 inch (216 mm) face height).

1) AEF-85.

2) AEF-100.

3) AEF-115.

4) AEF-130.

b. Performance:

1) Lifetime, 215 mph Wind Warranty

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft2to comply with the International Building Code.

3) Factory Mutual 1-270 approved for wind up lift protection.

4) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

3. Built-Up or Modified Version

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFM-85 - 8-1/2 inch (216 mm) face height).

1) AEFM-85.

2) AEFM-100.

3) AEFM-115.

4) AEFM-130.

b. Performance:

1) Lifetime, 215 mph Wind Warranty

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft2to comply with the International Building Code.

3) Factory Mutual 1-270 approved for wind up lift protection.

4) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

D. Anchor-Tite Canted Fascia: Three-part assembly consisting of a continuous extruded aluminum bar, exterior fascia and continuous formed galvanized steel cleat with fasteners.

1. Construction:

a. Fascia Metal:

** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.

1) .050 inch (1.27 mm) thick-formed aluminum.

2) .063 inch (1.6 mm) thick-formed aluminum.

b. Finish:

** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.

1) Natural aluminum mill finish.

2) Clear anodized aluminum.

3) Black anodized Aluminum.

4) Dark Bronze anodized aluminum.

5) Extra Dark Bronze anodized aluminum.

6) Champagne anodized aluminum.

7) Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.

8) Custom Kynar-500 color as selected by the Architect.

c. Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.

d. Extruded Bar: Shall be continuous 6063-T6 alloy aluminum in 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.

1) Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.

2) Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.

e. Waterdam: Standard 12 feet 0 inches (3.65 m) lengths of commercial type 24 gauge G-90 galvanized steel with pre-punched slotted holes.

f. Anchor Bar Cleat: Standard 12 feet 0 inches (3.65m) lengths of commercial type 20 gauge G-90 galvanized steel with pre-punched holes.

** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.

2. Existing Beveled Wood Nailer Version

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFC-1200 - 12 inch face height).

1) AEFC-55.

2) AEFC-900.

3) AEFC-1050.

4) AEFC-1200.

5) AEFC-1350.

b. Performance:

1) Lifetime, 215 mph Wind Warranty

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft2to comply with the International Building Code.

3) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

3. Galvanized Waterdam Version

a. Model:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFC-1052 - 10-1/2 inch face height).

1) AEFC-552.

2) AEFC-902.

3) AEFC-1052.

4) AEFC-1202.

5) AEFC-1352.

b. Performance:

1) Lifetime, 215 mph Wind Warranty

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft2to comply with the International Building Code.

3) Factory Mutual 1-270 approved for wind up lift protection.

4) Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".

E. Anchor-Tite Extended Canted Fascia:

1. Construction:

a. Fascia Metal:

** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.

1) .040 inch (1.01 mm) aluminum.

2) .063 inch (1.6 mm) aluminum.

b. Finish:

** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.

1) Natural aluminum mill finish.

2) Clear anodized aluminum.

3) Black anodized Aluminum.

4) Dark Bronze anodized aluminum.

5) Extra Dark Bronze anodized aluminum.

6) Champagne anodized aluminum.

7) Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.

8) Custom Kynar-500 color as selected by the Architect.

c. Extruded aluminum anchor bar.

d. Interlocking, concealed splice plate design prevent splice plate migration under the fascia panels.

1) Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.

2) Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.

e. Provided with anchor bar EPDM splice plates and fasteners.

** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.

2. Existing Beveled Wood Nailer Version

a. Sizes:

** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.

1) 8-1/2 inch (215.9 mm).

2) 10 inch (254 mm).

3) 11-1/2 inch (292.1 mm).

4) 13 inch (330.2 mm).

b. Performance:

1) Lifetime, 215 mph Wind Warranty

2) Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft2to comply with the International Building Code.