Concrete Paving ME- Building Group
SECTION 321313 - CONCRETE PAVING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
- Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division01 Specification Sections, apply to this Section.
1.2 SUMMARY
- This Section includes exterior cement concrete pavement for the following:
REVISE BELOW TO SUIT PROJECT.
- Driveways and roadways.
- Parking lots.
- Curbs and gutters.
- Walkways.
- Related Sections include the following:
LIST BELOW ONLY PRODUCTS AND CONSTRUCTION THAT THE READER MIGHT EXPECT TO FIND IN THIS SECTION BUT ARE SPECIFIED ELSEWHERE.
- Division3 Section "Cast-in-Place Concrete" for general building applications of concrete.
- Division31 Section "Earth Moving" for subgrade preparation, grading, and subbase course.
- Division32 Section "Concrete Pavement Joint Sealants" for joint sealants within concrete pavement and at isolation joints of concrete pavement with adjacent construction.
1.3 DEFINITIONS
DEFINITION BELOW REFERS TO THOSE MATERIALS THAT MAKE UP CEMENTITIOUS COMPONENT OF WATER-CEMENTITIOUS MATERIALS RATIO. PORTLAND CEMENT, BLENDED HYDRAULIC CEMENT, AND EXPANSIVE HYDRAULIC CEMENT ARE CLASSIFIED AS CEMENTS BY ACI318, WHILE FLY ASH AND OTHER POZZOLANS, GROUND GRANULATED BLAST-FURNACE SLAG, AND SILICA FUME ARE CLASSIFIED AS ADMIXTURES. EXPANSIVE HYDRAULIC CEMENT AND SILICA FUME ARE NOT IN THIS SECTION.
- Cementitious Materials: Portland cement alone or in combination with one or more of blended hydraulic cement, expansive hydraulic cement, fly ash and other pozzolans, ground granulated blast-furnace slag, and silica fume.
1.4 ACTION SUBMITTALS
- Product Data: For each type of product indicated.
- Shop drawings including the following:
- Paving joint layout indicating:
- Number and sequence of placements.
- Sizes and shapes of placements
- Types and spacing of joints.
- LEED Submittals:
- Product Data for CreditMR4: For products having recycled content, manufacturer documentation indicating percentages by weight of postconsumer and preconsumer recycled content.
- Include statement indicating costs for each product having recycled content.
- Product Data for Credit MR 5: For products and materials to comply with requirements for regional materials, provide documentation indicating location of product or material manufacturing location and the point of extraction, harvest, or recovery for each raw material.
- Include documentation on distance to project, contractor cost for each regional material, and percent by weight that is considered regional.
- Design Mixtures for CreditID1: For each concrete mixture containing fly ash as a replacement for portland cement or other portland cement replacements. For each design mixture submitted, include an equivalent concrete mixture that does not contain portland cement replacements, to determine amount of portland cement replaced.
- Other Action Submittals:
- Design Mixtures: For each concrete paving mixture. Include alternate design mixtures when characteristics of materials, Project conditions, weather, test results, or other circumstances warrant adjustments.
- Record drawings at project closeout according to Division1 Section "Project Closeout."
1.5 QUALITY ASSURANCE
- Where directed or specified, provide cement concrete paving according to materials, workmanship, and other applicable requirements of standard specifications of local highway authorities or State Department of Transportation.
- Measurement and payment provisions and safety program submittals included in standard specifications do not apply to this Section.
- Manufacturer Qualifications: Manufacturer of ready-mixed concrete products complying with ASTMC94 requirements for production facilities and equipment.
DELETE SUBPARA BELOW IF NOT REQUIRED.
- Manufacturer must be certified according to the National Ready Mix Concrete Association's Plant Certification Program.
- Installer Qualifications: An experienced installer who has completed pavement work similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance.
RETAIN PARA BELOW IF CONTRACTOR OR MFR SELECTS TESTING AGENCY FOR MIX DESIGN, MATERIAL TEST REPORTS, OR FIELD QUALITY CONTROL.
- Testing Agency Qualifications: Employ an independent testing agency, acceptable to the Owner or Owner’s representative, qualified to conduct the testing indicated in this section according to ASTMC1077 and ASTME329.Demonstrate to Owner or Owner’s Representative’s satisfaction, that the independent testing agency has the experience and capability to satisfactorily conduct the testing indicated without delaying the Work.
- Source Limitations: Obtain each type or class of cementitious material of the same brand from the same manufacturer's plant and each aggregate from one source.
- ACI Publications: Comply with ACI301, "Specification for Structural Concrete," unless modified by the requirements of the Contract Documents.
- Concrete Testing Service: Engage a qualified independent testing agency to perform material evaluation tests and to design concrete mixes.
1.6 PROJECT CONDITIONS
DELETE THIS ARTICLE IF NOT REQUIRED.
- Traffic Control: Maintain access for vehicular and pedestrian traffic as required for other construction activities.
PART 2 - PRODUCTS
2.1 FORMS
DELETE OR REVISE MATERIALS BELOW TO SUIT PROJECT.
- Form Materials: Plywood, metal, metal-framed plywood, or other approved panel-type materials to provide full-depth, continuous, straight, smooth exposed surfaces.
- Use flexible or curved forms for curves of a radius 100 feet or less.
- Form-Release Agent: Commercially formulated form-release agent that will not bond with, stain, or adversely affect concrete surfaces and will not impair subsequent treatments of concrete surfaces.
2.2 STEEL REINFORCEMENT
- Recycled Content: Postconsumer recycled content plus one-half of pre-consumer recycled content not less than 25 percent.
DELETE OR REVISE PARAS BELOW TO SUIT REINFORCEMENT REQUIREMENTS.
- Plain-Steel Welded Wire Fabric: ASTMA185, fabricated from as-drawn steel wire into flat sheets only. Welded wire fabric supplied in rolls are not acceptable.
- Reinforcement Bars: ASTMA615/A615M, Grade60, deformed.
- Joint Dowel Bars: Plain steel bars, ASTMA615/A615M, Grade60. Cut bars true to length with ends square and free of burrs.
- Tie Bars: ASTMA615/A615M, Grade60, deformed.
SELECT PARA ABOVE OR BELOW. TIE BARS ABOVE OR HOOK BOLTS BELOW MAY BE USED FOR CONNECTION BETWEEN NEW AND EXISTING PAVEMENT AND BETWEEN PAVEMENT AND GUTTERS.
- Hook Bolts: ASTMA307, GradeA, internally and externally threaded. Design hook-bolt joint assembly to hold coupling against pavement form and in position during concreting operations, and to permit removal without damage to concrete or hook bolt.
- Reinforcing Supports: Chairs and similar devices for spacing, supporting, and fastening reinforcement bars, welded wire fabric, and dowels in place. Manufacture supports according to CRSI's "Manual of Standard Practice" from steel wire, plastic, or precast concrete or fiber-reinforced concrete of greater compressive strength than concrete, and as follows; Use of bricks is not acceptable.
DELETE OR REVISE SUBPARAS BELOW TO SUIT PROJECT.
- Equip wire bar supports with sand plates or horizontal runners where base material will not support chair legs.
- For epoxy-coated reinforcement, use epoxy-coated or other dielectric-polymer coated wire bar supports.
2.3 CONCRETE MATERIALS
- General: Use the same brand and type of cementitious material from the same manufacturer throughout the Project.
SELECT PORTLAND CEMENT ALONE OR IN COMBINATION WITH FLY ASH OR GROUND GRANULATED BLAST-FURNACE SLAG IN SUBPARAS BELOW. REVISE PORTLAND CEMENT TO TYPEIII IF REQUIRED FOR PROJECT.
- Portland Cement: Unless otherwise indicated on the Drawings, ASTMC150, TypeI or II.Supplement with the following:
- Fly Ash: ASTMC618, ClassF.
- Ground Granulated Blast-Furnace Slag: ASTMC989, Grade100 or 120.
- Regional Materials: Concrete products shall be manufactured within 500 miles of Project site from materials that have been extracted, harvested, or recovered, as well as manufactured, within 500 miles of Project site.
- Aggregate: Unless otherwise indicated on the Drawings; ASTMC33, uniformly graded, from a single source, with coarse aggregate Class 4S.
- Do not use fine or coarse aggregates containing substances that cause spalling.
- Water: Potable and complying with ASTMC94/C94M.
2.4 ADMIXTURES
- General: Admixtures certified by manufacturer to contain not more than 0.1 percent water-soluble chloride ions by mass of cement and to be compatible with other admixtures.
- Air-Entraining Admixture: Unless otherwise specified by local highway authorities or State Department of Transportation, ASTMC260.
- Water-Reducing Admixture: ASTMC494, TypeA.
- High-Range, Water-Reducing Admixture: ASTMC494, TypeF.
2.5 CURING MATERIALS
SELECT CURING AIDS AND MATERIALS FROM PARAS BELOW, RETAINING OPTIONAL MATERIALS IF APPLICABLE.
- White Waterborne Membrane-Forming Curing Compound: ASTMC309, Type2, ClassB.
2.6 RELATED MATERIALS
SELECT ONE OF THREE PARAS BELOW.
- Expansion- and Isolation-Joint-Filler Strips: ASTMD1751, asphalt-saturated cellulosic fiber.
2.7 CONCRETE MIXES
- Prepare design mixes, proportioned according to ACI211.1 and ACI301, for each type and strength of normal-weight concrete determined by either laboratory trial mixes or field experience.
- Use a qualified independent testing agency for preparing and reporting proposed mix designs for the trial batch method.
- Do not use Owner's field quality-control testing agency as the independent testing agency.
- Proportion mixes to provide concrete with the following properties:
SELECT STRENGTH FROM SUBPARAS BELOW. ADD FLEXURAL STRENGTH IF REQUIRED.
- Compressive Strength (28 Days): 4000 psi.
- Maximum Water-Cementitious Materials Ratio: 0.45.
RETAIN SUBPARA ABOVE FOR CONCRETE EXPOSED TO DEICERS OR SUBJECT TO FREEZING AND THAWING WHILE MOIST. RETAIN SUBPARA BELOW FOR CONCRETE REQUIRED TO HAVE LOW WATER PERMEABILITY.
- Slump Limit: 3 inches.
- Slump Limit for Concrete Containing High-Range Water-Reducing Admixture: Not more than 8 inches after adding admixture to plant- or site-verified, 2- to 3-inch slump.
- Add air-entraining admixture at manufacturer's prescribed rate to result in concrete at point of placement having an air content as follows within a tolerance of plus or minus 1.5 percent:
- Air Content: 6.5 percent in accordance with ASTM C173 or ASTM C231.
- Cementitious Materials:Use fly ash, pozzolan, ground granulated blast-furnace slag, and silica fume as needed to reduce the total amount of portland cement, which would otherwise be used, by not less than 40 percent.Limit percentage, by weight, of cementitious materials other than portland cement in concrete as follows:
- Fly Ash or Pozzolan: 25 percent.
- Ground Granulated Blast-Furnace Slag: 50 percent.
- Combined Fly Ash or Pozzolan, and Ground Granulated Blast-Furnace Slag: 50 percent, with fly ash or pozzolan not exceeding 25 percent.
2.8 CONCRETE MIXING
- Ready-Mixed Concrete: Comply with requirements and with ASTMC94.
PART 3 - EXECUTION
3.1 PREPARATION
DELETE PARA BELOW IF NOT REQUIRED.
- Proof-roll prepared subbase surface to check for unstable areas and verify need for additional compaction. Proceed with pavement only after nonconforming conditions have been corrected and subgrade is ready to receive pavement.
- Install aggregate subbase and base courses in accordance with Division 31 Section “Earth Moving”.
- Remove loose material from compacted subbase surface immediately before placing concrete.
3.2 EDGE FORMS AND SCREED CONSTRUCTION
- Set, brace, and secure edge forms, bulkheads, and intermediate screed guides for pavement to required lines, grades, and elevations. Install forms to allow continuous progress of work and so forms can remain in place at least 24 hours after concrete placement.
- Clean forms after each use and coat with form release agent to ensure separation from concrete without damage.
3.3 STEEL REINFORCEMENT
- General: Comply with CRSI's "Manual of Standard Practice" for fabricating reinforcement and with recommendations in CRSI's "Placing Reinforcing Bars" for placing and supporting reinforcement.
- Clean reinforcement of loose rust and mill scale, earth, ice, or other bond-reducing materials.
- Arrange, space, and securely tie bars and bar supports to hold reinforcement in position during concrete placement. Maintain minimum cover to reinforcement.
- Install welded wire fabric in lengths as long as practicable. Lap adjoining pieces at least one full mesh, and lace splices with wire. Offset laps of adjoining widths to prevent continuous laps in either direction.
3.4 JOINTS
- General: Construct construction, isolation, and contraction joints and tool edgings true to line with faces perpendicular to surface plane of concrete. Construct transverse joints at right angles to centerline, unless otherwise indicated.
- When joining existing pavement, place transverse joints to align with previously placed joints, unless otherwise indicated.
- The length to width ratio of any jointed concrete panel shall not exceed 1.25:1 and shall not exceed 15 feet in length unless otherwise noted.
- Construction Joints: Set construction joints at side and end terminations of pavement and at locations where pavement operations are stopped for more than one-half hour, unless pavement terminates at isolation joints.
- Isolation Joints: Form isolation joints of preformed joint-filler strips abutting concrete curbs, catch basins, manholes, inlets, structures, walks, other fixed objects, and where indicated.
EXPANSION JOINTS ARE TYPES OF ISOLATION JOINTS. REVISE SPACING TO SUIT PROJECT OR DELETE IF NOT REQUIRED.
- Locate isolation joints where indicated.
- Extend joint fillers full width and depth of joint.
- Terminate joint filler not less than 1/2 inch or more than 1 inch below finished surface.
- Furnish joint fillers in one-piece lengths. Where more than one length is required, lace or clip joint-filler sections together.
- Protect top edge of joint filler during concrete placement with metal, plastic, or other temporary preformed cap. Remove protective cap after concrete has been placed on both sides of joint.
DELETE PARA BELOW IF NO DOWELED JOINTS ARE REQUIRED. REVISE IF PRECOATED DOWELS ARE REQUIRED.
- Install dowel bars and support assemblies at joints where indicated. Lubricate or sleeve one-half of dowel length to prevent concrete bonding to one side of joint.
TERMS "CONTRACTION JOINT" AND "CONTROL JOINT" HAVE BEEN USED INTERCHANGEABLY IN THE PAST. RECENT ACI DOCUMENTS USE "CONTRACTION JOINT." REVISE DESCRIPTION IN PARA BELOW IF "CONTROL JOINT" IS PREFERRED.
- Contraction Joints: Form weakened-plane contraction joints, sectioning concrete into areas as indicated. Construct contraction joints for a depth equal to one-fourth of the concrete thickness, as follows:
SELECT TYPE OF JOINT-FORMING METHOD REQUIRED OR RETAIN BOTH AT CONTRACTOR'S OPTION. ADD SPACING OF JOINTS IF NOT INDICATED ON DRAWINGS.
- Sawed Joints: Form contraction joints with power saws equipped with shatterproof abrasive or diamond-rimmed blades. Cut 1/4-inch-wide joints into concrete when cutting action will not tear, abrade, or otherwise damage surface and before developing random contraction cracks.
- Contraction joint spacing shall not exceed 15-foot intervals in any direction, unless otherwise noted.
- Edging: Tool edges of pavement, gutters, curbs, and joints in concrete after initial floating with an edging tool to the following radius. Eliminate tool marks on concrete surfaces.
- Radius: 1/4 inch for sidewalks and curbs.
- Radius: 1/8 inch for pavement.
3.5 CONCRETE PLACEMENT
- Inspection: Before placing concrete, inspect and complete formwork installation, reinforcement steel, and items to be embedded or cast in. Notify other trades to permit installation of their work.
- Remove snow, ice, or frost from subbase surface and reinforcement before placing concrete. Do not place concrete on frozen surfaces.
- Moisten subbase to provide a uniform dampened condition at the time concrete is placed. Do not place concrete around manholes or other structures until they are at the required finish elevation and alignment.
- Comply with requirements and with recommendations in ACI304R for measuring, mixing, transporting, and placing concrete.
DELETE PARA BELOW IF ADDING WATER AFTER BATCH MIXING IS PERMITTED. REVISE IF CONDITIONAL APPROVAL WILL BE PERMITTED. ACI301 AND ASTMC94 PERMIT WATER TO BE ADDED TO CONCRETE MIX ON-SITE, UP TO AMOUNT ALLOWED IN DESIGN MIX.