1.FLOOR, raised slab(to match existing elevation), 4” minimum, 3500psi concrete, with wire & 6mil poly. Brick up to floor level. Landscaping around foundation, seed & straw.
2.EXTERIOR WALLS, 2X4 wood studs, 16” OC spacing, Insulated to R-15. Outside sheathing 7/16”OSB, wrapped with (TYPAR or TYVEC). Outside vinyl siding “Carved Wood” or equal, (.044 thickness min, soffit .05 min, anti-weathering protection, 50 year full replacement warranty min.) Color to match existing.
3.ROOF, wood mono trusses, with 36” fall in the total span. 24” OC spacing. Insulated to R-38.Roof sheathing 5/8” OSB. Roofing material (continuous multi-rib 29ga. min)
4.WINDOWS, double hung, vinyl clad, (new construction type), Low E glass, argon filled, full screen, tilt, no grids.
5.DOORSHARDWAREto match existing. Trim to match existing.
6.CEILINGS lay in, 2’ X 2’
7.INTERIOR WALLS, ½” drywall. Soundproofing in all bathroom walls. Vinyl baseboard.
8.INTERIOR FLOORS. Commercial grade glue down tile.
9.PAINT, Sherwin Williams Cashmere, 1 coat primer, 2 coats finish, (colors to match existing)
10.ELECTRICAL, lights to be lay in type to match existing office lights, cat-5 cable and terminations in both offices, for PC, telephone cable, and phone jacks both offices, receptacles as per drawing, switches as per drawing,
11.PLUMBING, All new Kohler fixtures. (Installed to ADA specs) Water closets, flushvalve (Zurn or Sloan), ADA height, open front seats. Urinals, big model, automatic flush valve, (Zurn or Sloan). Sinks, use Delta or Moen single lever faucets. Water lines all type L copper, (City will provide new 1 ½” water service) east side, tie hot water lines to existing, install frost proof hose bib on east side of building. Provide new bi-level water cooler, (Oasis or equal). DWV, schedule 40 PVC, use existing sewer tap on east side of building.
12.BATHROOMSTALLS, & HANDICAP BARS. Stalls & dividers baked enamel finish, bars stainless steel, installed by contractor to ADA specs.
13. HVAC, All Heating and A/C ducts shall be run from existing system and sized for best efficiency.
- GENERAL CONTRACTOR SHALL LIST ALL SUB CONTRACTORS IN FINAL BID, SHALL PROVIDE PROOF OF INSURANCE, & PROOF OF LICENSE. SUBMIT ALL REQUIRED TAX FORMS (IF NEW VENDOR). GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS. (CITY WILL WAVE PERMIT FEES & UTILITY FEES; DO NOTINCLUDE THIS IN BID.)
- CONTRACTOR‘S WISHING TO SUBMIT A BID WILL BEREQUIRED TO ATTEND PRE-BID MEETING.
(Floor Plan will be Available)___
- TIME / DATE for PRE-BID MEETING: _Tuesday, 2/2/2016, @ 9:30 AM___
LOCATION: Public Works Office, 132 Wilkie Street, Forest City.____
- DEADLINE TO SUBMIT BID, ___Friday 2 /15 /16 @2:00 PM____
- SUBMIT ALL SEALED BIDS TO: FOREST CITY, CITY CLERKS OFFICE, 128 N. POWELL ST.____
- BID OPENING: FOREST CITY, CITY CLERKS OFFICE, 128 N. POWELL ST. Friday 2 / 15 / 16, @2:00PM
- WORK MUST BE COMPLETED, FINALIZED, WITH A CO, AND ALL PAYMENT REQUESTS SUBMITTED, BY (JUNE 30, 2016)
- QUESTIONS, PLEASE CONTACT, (STEWART BRISCOE, OR JON HOYLE) AT, (828-245-0149)