Cris Release Notes 06.04c v1.1

Copyright

© Healthcare Software Systems 2004

Registered Office: Priory Road, Mansfield-Woodhouse, Nottinghamshire, NG19 9LP

General Information

This release replaces all previous major, minor and emergency releases.

All changes included in a major release will also be included in a minor release.

There is no downtime needed to install a release unless specifically mentioned in the Implementation Issues section.

All sites can be upgraded to this release of Cris.

No changes are included in a release until the change passes all tests and that change has no known issues or has caused any new known issues at the time of release.

Each release of Cris is not normally released with any known issues unless specifically mentioned in the known issues section.

Release Dates & Reason For Release

06.04 22/05/2006 Audit Release to include new functionality and fixes.

06.04a 27/06/2006 Additional fixes and improvements to Audit release.

06.04b 21/07/2006 Patch to fix Referring Location Prefix problem found in 06.04a

06.04c 31/07/2006 Fix to increase Oracle fetch size and undo change to report info list.

Notes on the following tables:

"HSS Ref" – these are internal HSS change numbers.

"LSP Ref" – these relate to Fujitsu Incident references or RFC references.

"Request Only" – these changes are only made active only on specific request by a trust.

"Interest to Trust" – these changes are deemed to be of significance to trusts either because they impacts end users, require trust action or are desirable new features/fixes, which trusts are most likely to take advantage of.

New Functionality

HSS Ref / LSP Ref / Description / Request Only / Interest to Trust
86780 / Export diff and import format tool
89205 / Change/delete old status records via right click menu / Y
89615 / User in multiple user groups / Y
89631 / PACS examination names in reports
89971 / Print pregnancy fields / Y / Y
90066 / Obstetric graph cross size configuration / Y / Y
90147 / Stats field / Y
90210 / Recount all button / Y
90215 / Add national user id
90441 / Interface status and message manager views / Y / Y
90680 / Close tab icon / Y
90711 / 23417 / Waiting list waiting time / Y
90719 / Dual reporting / Y
90933 / Busy hourglass cursor / Y
91082 / SNOWMED CT field
91245 / Printing fexiforms
92062 / Agfa PACS dictation triggers
92346 / Added configuration settings to the PACS interface
92385 / CRIS Help / Y
92416 / Intended radiologist / Y
94129 / Network test tool

Issues Resolved

HSS Ref / LSP Ref / Description / Request Only / Interest to Trusts
74393 / Enter diagnosis codes using coded phrases
86783 / Improved print content editor
86966 / Delete film track
88701 / Append Dictation directory to base directory
88801 / 23358 / Scan reason when foetus is added / Y
89022 / First patient load time
89080 / Event tooltip null pointer exception
89085 / Work list status popup / Y
89214 / New dictation priority colour / Y
89235 / 24634 / Inactive fields colour / Y
89385 / mA decimal places / Y
89429 / PCE cut copy and paste of formatted text
89489 / Stats selectable fields is displayed in alphabetical order
89508 / Stats total line value field
89513a / Dictation page focus issues
89513b / Update unreported list when a dictation is finished / Y
89516 / Disable practice field
89523 / Searching for old dictations / Y
89528 / Filter Radiologist unverified reports by site code / Y
89623 / Batch print order
89762 / Display coded phrases of dictator not user / Y
89777 / Reflex order messages
89802 / Tape controls / Y
89970 / BPD and FL fields / Y
89972 / Liquor volume table / Y
90063 / Cancel order title
90147 / Total lines on stats csv format / Y
90246 / PACS patient id on merge
90319 / New features in print content editor
90340 / GP in patients / Y / Y
90347 / User setting inheritance / Y
90455 / Marking print previewed reports as printed
90459 / New event on patient search
90534 / Change password / Y
90554 / Batch print order typed by
90573 / Blank obstetric reports / Y
90589 / Pending date
90624 / Spell check
90625 / Join patient message
90889 / Printing twins obstetric reports / Y
90996 / Non unique hospital numbers
91072 / Restrictions on the “in” selections in stats
91085 / Referrer Search
91119 / Site codes auto select / Y
91123 / Revised ARSAC limit error message
91132 / Increase code field size in STYPE
91311 / Unmerge screen does not fit / Y
91336 / 58473 / Request card button / Y
91384 / Sorting change hospital page
91414 / Exam validation group multi
91463 / Report Info List Changes / Y
91465 / Available fields list in stats total lines
91467 / Speech mike fixed
91487 / Aborted dictation problems / Y
91494 / 44294 / DOB error on dictation list
91510 / Sex hover help
91666 / Staff table queries
91709 / Site code setup bug
91721 / Porter list columns
91732 / Diary exceptions
91778 / First exam details
91820 / 59577 / Request category default / Y
91994 / Results message ID change
92019 / Obstetric exam warning / Y
92020 / User ID tool tip text
92234 / Additional debugging on today’s messages
92237 / Tool tip location
92244 / Diary mouse pointer
92297 / Dept lookup in rooms setup
92337 / Blank NTE on orders
92340 / Merge problem on interface
92350 / PAS not updating GP to blank
92368 / Backslashes in XR settings / Y
92437 / Urgency on orders list / Y
92452 / Speciality default
92518 / KH12 Speed Increase / Y
92570 / Lookup table refresh
90720 / Radiol type field in staff setup
92756 / order comms status reason
92732 / Report info list dictated / Y
92791 / Useful error messages
92798 / Total line number alignment
92797 / Count decimals in statistics total lines
90901 / User timeout
92789 / Scanning crashes / Y
89640 / Confirm LR
92843 / Database reconnect / Y
92793 / Caching of SQL requests
91443 / Fix to status load routine for use in application server
91543 / Stats waiting time calculation
93022 / Flexiform focus traversal
90879 / Schema changes to paper and dept
93026 / User setup / Y
93043 / Demographic history validation
86780 / Print System Changes
93035 / AGFA PACS 2 way DTI
93483 / Change Scan Form
93727 / Sorting waiting list by pending column
93850 / Rescan request card / Y
94681 / String field operators in stats total lines
95124 / Checked ID
94605 / Lowercase hospital numbers
94622 / Today’s messages null date
95321 / P0058981
P0073646
P0065253 / Login SQL Alterations
95980 / P0058981
P0073646
P0065253 / Download of spell.txt on login
95967 / Stats methods on server
97315 / 75904 / Referring Location Prefix
97802 / P0058981
P0073646
P0065253 / Fetch size increased to improve speed on high latency networks. / Y
97807 / 77654 / Undo change 89513b Unreported Info List refresh / Y

Systems or Other Applications Affected

Implementation Issues Summary

Including Data Populating Actions and Downtime Necessary and user training required.

Implemented by Trust

New user security setting GENERAL ChangeStatus available to be used.

To continue to see Print Setup, Printing and PrintContentEditor in Cris Setup requires the users group to have the permission VIEWS.PRINTING = Y.

See change description later in document for details.

Implemented by HSS

This change is not inherently backwards compatible. The existing data will need to be checked. The CRISLIQ table will need the previously used CRISSEEN values added to maintain backwards compatibility.

Also the print definition will need to be checked to ensure it uses the new table liquor instead of liquorseen on dating scan 2,4 and growth + anomaly scans 4,6 of anatomy sections.

For those users that require a change in cross size or thickness the print format for obstetrics graphs will require modification.

2 new fields needed in DATAFLDS table. They are EXAMS.WAS WAITING, and EXAMS.WAITING N PLAND.

Print Preview requires loading a preview template into the database. This will not affect any other formats or data.

NPINHERIT table needs adding to the database schema.

User setting VIEWS PERMISSIONS needs to be available.

Configure JBoss and cris settings to allow access to the interface status and message manager. See release note 90441 Interface status and msg manager.

Need to run the new database schema.

The following line needs to be added to the relevant report format (reportrep.vtl) where the flexiform should be printed:

\\FLEXI$report.getReportKey()

The datafield of DERIVED.NO OF EXAMS needs to have its expression changed to getNumberOfExams(EXAMS.EXAMINATION).

Cris 06.04 requires these schema changes to be made.

Applying a unique index will create problems if there are duplicate rows. In this case all but one of the duplicate rows should be deleted. Since there are only 10-50 rows in this table per SHA, this will not take long.

Need to set LOCATION.PACSIdentifier so that desktop integration can determine the correct patient ID to send to PACS.

Need to set LOCATION.UID.Site so that desktop integration can determine the study UID.

Requires an HL7 PACS interface configured to send study UID from CRIS.

Known Issues

HSS Ref / LSP Ref / Description
92912 / Fields on event details page not saved when you click process à finished à save

Additional Information

None

Installation Method

Software placed on server. Each client automatically updated on next reconnect to application.

Appendix A

Change Details

Change details are presented in chronological order – i.e. in the sequence in which the changes have been made to the product build. The net effect of a change must be considered in the light of such sequencing. The format of future release notes is under review with the aim of improving intelligibility to end users.

Initiator / HSS / HSS Change Ref. No. / 74393
Incident No. / LSP RFC No.
Date Raised / 22/12/05 / Initiator Ref. No.
Title of Change / Diagnosis codes from phrases
CRIS Versions Reported In / CRIS Versions containing change. / 06.04

Reason For Change

The report finished page did not display diagnosis codes entered via the coded phrases in the report page.

Change Description

When a coded phrase is inserted with a diagnosis code the diagnosis code is added to the event.

Classes and Tables Changed

hss.radiology.reports.PhrasePrompt

hss.radiology.reports.CrisEditor

Implementation Issues

Including Data Populating Actions and Downtime Necessary.

None

Test Results.

Each change included in the release has passed all tests with no known problems.

Number Of Tests / Test Description / Tests Passed / Tests Failed
5 / Ensured the diagnosis codes entered in the report via coded phrases appeared on the report finished page. / 5 / 0
Initiator / HSS / HSS Change Ref. No. / 86780
Incident No. / LSP RFC No.
Date Raised / 07/12/05 / Initiator Ref. No.
Title of Change / Export, diff and import format tool
CRIS Versions Reported In / 05.12 / CRIS Versions containing change. / 06.04

Reason For Change

To add a tool to export print formats, highlight the differences and upgrade them.

Change Description

Added a tool to export formats, diff them and upgrade them. Also added the ability to use it for Rooms, Departments and Paper types. Can filter by site or trust and include or exclude generic formats

This tool is not intended for trust use.

Classes and Tables Changed

hss.utils.DiffPanel

hss.app.pages.DiffExpUpgrade

hss.app.actions.tools.FormatCustoms

hss.app.cris

Implementation Issues

Including Data Populating Actions and Downtime Necessary.

None

Test Results.

Each change included in the release has passed all tests with no known problems.

Number Of Tests / Test Description / Tests Passed / Tests Failed
5 / Tested exporting, then importing showed which formats were to be overwritten or were new and that viewing/diffing formats as appropriate worked correctly. / 5 / 0
Initiator / HSS / HSS Change Ref. No. / 86783
Incident No. / LSP RFC No.
Date Raised / 09/12/05 / Initiator Ref. No.
Title of Change / Print Content Editor changes
CRIS Versions Reported In / 05.12 / CRIS Versions containing change. / 06.04

Reason For Change

To improve the functionality of the print content editor.

Change Description

Made changes to display bold, italic and underline in the editor as bold, italic and underline instead of the markup. Also added a ‘grammar checker’ to check to warn attempts to parse formats that don’t exist and limited support for pasting formatted text from Microsoft Word documents.

Classes and Tables Changed

hss.admintools.setup.PrintContentEditor

Implementation Issues

Including Data Populating Actions and Downtime Necessary.

None

Test Results.

Each change included in the release has passed all tests with no known problems.

Number Of Tests / Test Description / Tests Passed / Tests Failed
5 / Tested viewing formats displayed the correct sections as bold, italic, underlined or as a red strikethrough for formats that don’t exist and ensured that the text survived a save and reload intact. / 5 / 0
5 / Checked that pasting from Microsoft Word worked from a range of documents.
Initiator / HSS / HSS Change Ref. No. / 86966
Incident No. / LSP RFC No.
Date Raised / 03/01/2005 / Initiator Ref. No.
Title of Change / Delete Film Track Bug
CRIS Versions Reported In / 05.12 / CRIS Versions containing change. / 06.04

Reason For Change