Text for tenders /

AMFLO SONIC UFA 113

Ultrasonic flowmeter

Version with external supply 5V DC

Pulse value 0.1 L/pulse

UFA-113, threaded version, PN 16

95471 / AMFLO SONIC UFA-113 15 0.6_110_3/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G3/4”
Max. operating pressure: PN 16
Length: 110 mm
Nominal diameter: DN 15
Horizontal or vertical mounting
Nominal flow rate qp: 0.6 m³/h
Max. flow rate qs: 1.2 m³/h
Min. flow rate: 0.006 m³/h
Kvs-value: 2.06 m³/h
Pressure loss at qp: 85 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95472 / AMFLO SONIC UFA-113 15 1.5_110_3/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G3/4”
Max. operating pressure: PN 16
Length: 110 mm
Nominal diameter: DN 15
Horizontal or vertical mounting
Nominal flow rate qp: 1.5 m³/h
Max. flow rate qs: 3 m³/h
Min. flow rate: 6 l/h
Kvs-value: 5.48 m³/h
Pressure loss at qp: 75 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95475 / AMFLO SONIC UFA-113 20 2.5_130_G1 N 0.1
Ultrasonic flowmeter
Threaded connection: G1”
Max. operating pressure: PN 16
Length: 130 mm
Nominal diameter: DN 20
Horizontal or vertical mounting
Nominal flow rate qp: 2.5 m³/h
Max. flow rate qs: 5 m³/h
Min. flow rate qi: 10 l/h
Kvs-value: 7.91m³/h
Pressure loss at qp: 100 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95476 / AMFLO SONIC UFA-113 20 2.5_190_G1 N 0.1
Ultrasonic flowmeter
Threaded connection: G1”
Max. operating pressure: PN 16
Length: 190 mm
Nominal diameter: DN 20
Horizontal or vertical mounting
Nominal flow rate qp: 2.5 m³/h
Max. flow rate qs: 5 m³/h
Min. flow rate qi: 10 l/h
Kvs-value: 7.91m³/h
Pressure loss at qp: 100 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95465 / AMFLO SONIC UFA-113 25 3.5_135_5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 135 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 3.5 m³/h
Max. flow rate qs: 7 m³/h
Min. flow rate qi: 35 l/h
Kvs-value: 16.69 m³/h
Pressure loss at qp: 44 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95467 / AMFLO SONIC UFA-113 25 3.5_150_5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 150 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 3.5 m³/h
Max. flow rate qs: 7 m³/h
Min. flow rate qi: 35 l/h
Kvs-value: 16.69 m³/h
Pressure loss at qp: 44 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95469 / AMFLO SONIC UFA-113 25 3.5_260_5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 260 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 3.5 m³/h
Max. flow rate qs: 7 m³/h
Min. flow rate qi: 35 l/h
Kvs-value: 16.69 m³/h
Pressure loss at qp: 44 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95466 / AMFLO SONIC UFA-113 25 6_135_5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 135 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95468 / AMFLO SONIC UFA-113 25 6_150_5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 150 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95470 / AMFLO SONIC UFA-113 25 6_260_G5/4 N 0.1
Ultrasonic flowmeter
Threaded connection: G5/4”
Max. operating pressure: PN 16
Length: 260 mm
Nominal diameter: DN 25
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Ambient temperature: 5 ... 55 °C
Pulse value:0.1 l/pulse
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95473 / AMFLO SONIC UFA-113 32 6_150_G3/2 N 0.1
Ultrasonic flowmeter
Threaded connection: G3/2”
Max. operating pressure: PN 16
Length: 150 mm
Nominal diameter: DN 32
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95463 / AMFLO SONIC UFA 113 40 10_200_G2 N 0.1
Ultrasonic flowmeter
Threaded connection: G 2"
Max. operating pressure: PN 16
Length: 200 mm
Nominal diameter: DN 40
Horizontal or vertical mounting
Nominal flow rate qp: 10.0 m³/h
Max. flow rate qs: 20.0 m³/h
Min. flow rate qi: 0.100 m³/h
Kvs-value: 32.4 m³/h
Pressure loss at qp: 95 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95474 / AMFLO SONIC UFA-113 40 10_300_G2 N 0.1
Ultrasonic flowmeter
Threaded connection: G2”
Max. operating pressure: PN 16
Length: 300 mm
Nominal diameter: DN40
Horizontal or vertical mounting
Nominal flow rate qp: 10 m³/h
Max. flow rate qs: 20 m³/h
Min. flow rate qi: 100 l/h
Kvs-value: 32.4 m³/h
Pressure loss at qp: 95 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2

UFA-113, flanged version, PN 25

95482 / AMFLO SONIC UFA-113 20 2.5_190_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL20
Max. operating pressure: PN25
Length: 190 mm
Nominal diameter: DN20
Horizontal or vertical mounting
Nominal flow rate qp: 2.5 m³/h
Max. flow rate qs: 5 m³/h
Min. flow rate qi: 19 l/h
Kvs-value: 7.91 m³/h
Pressure loss at qp: 100 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95484 / AMFLO SONIC UFA-113 25 6_260_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL25
Max. operating pressure: PN25
Length: 260 mm
Nominal diameter: DN25
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95481 / AMFLO SONIC UFA-113 32 6.0_260_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL32
Max. operating pressure: PN25
Length: 260 mm
Nominal diameter: DN32
Horizontal or vertical mounting
Nominal flow rate qp: 6 m³/h
Max. flow rate qs: 12 m³/h
Min. flow rate qi: 24l/h
Kvs-value: 16.77 m³/h
Pressure loss at qp: 128 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value:0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95484 / AMFLO SONIC UFA-113 40 10_300_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL40
Max. operating pressure: PN25
Length: 300 mm
Nominal diameter: DN40
Horizontal or vertical mounting
Nominal flow rate qp: 10 m³/h
Max. flow rate qs: 20 m³/h
Min. flow rate qi: 100 l/h
Kvs-value: 32.4 m³/h
Pressure loss at qp: 95 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95480 / AMFLO SONIC UFA-113 50 15_270_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL50
Max. operating pressure: PN25
Length: 270 mm
Nominal diameter: DN50
Horizontal or vertical mounting
Nominal flow rate qp: 15 m³/h
Max. flow rate qs: 30 m³/h
Min. flow rate qi: 150 l/h
Kvs-value: 53 m³/h
Pressure loss at qp: 80 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
95479 / AMFLO SONIC UFA-113 65 25_270_FL N 0.1
Ultrasonic flowmeter
Flanged connection: FL65
Max. operating pressure: PN25
Length: 300 mm
Nominal diameter: DN65
Horizontal or vertical mounting
Nominal flow rate qp: 25 m³/h
Max. flow rate qs: 50 m³/h
Min. flow rate qi: 250 l/h
Kvs-value: 91.3 m³/h
Pressure loss at qp: 75 mbar
Temperature range: 5 ... 150 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 0.1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2

Version with external supply 5V DC

Pulse value 1 L/pulse (2.5 L/pulse)

UFA-113, threaded version, PN 16

94770 / AMFLO SONIC UFA-113 15 0.6_110_G3/4 N 1L
Ultrasonic flowmeter
Threaded connection: G3/4”
Max. operating pressure: PN 16
Length: 110 mm
Nominal diameter: DN15
Horizontal or vertical mounting
Nominal flow rate qp: 0.6 m³/h
Max. flow rate qs: 1.2 m³/h
Min. flow rate: 0.006 m³/h
Kvs-value: 2.06 m³/h
Pressure loss at qp: 85 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 1 l
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
94771 / AMFLO SONIC UFA-113 15 1.5_110_3/4 N 1L
Ultrasonic flowmeter
Threaded connection: G3/4”
Max. operating pressure: PN 16
Length: 110 mm
Nominal diameter: DN15
Horizontal or vertical mounting
Nominal flow rate qp: 1.5 m³/h
Max. flow rate qs: 3 m³/h
Min. flow rate: 6 l/h
Kvs-value: 5.48 m³/h
Pressure loss at qp: 75 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)
Approval according to MID 2004/22/EG
EN1434 Class 2
94772 / AMFLO SONIC UFA-113 20 2.5_130_G1 N 1L
Ultrasonic flowmeter
Threaded connection: G1”
Max. operating pressure: PN 16
Length: 130 mm
Nominal diameter: DN20
Horizontal or vertical mounting
Nominal flow rate qp: 2.5 m³/h
Max. flow rate qs: 5 m³/h
Min. flow rate qi: 10 l/h
Kvs-value: 7.91m³/h
Pressure loss at qp: 100 mbar
Temperature range: 5 ... 130 °C
Inlet section: 0 x DN
Outlet section: 0 x DN
Pulse value: 1 l/pulse
Ambient temperature: 5 ... 55 °C
Supply: 5V DC (e.g. by CALEC ST)