Appendix EQ, Test Equipment Recommendations and Calibration

Appendix EQ

Test Equipment Recommendations & Calibration

a) Clothes Washer

Type: Fisher and Paykal top loading clothes washer

Model: GWL 11 US

Serial: UKN627345

Input Voltage: 110 ~ 120 V, 60 Hz, 7 Amps


b) Clothes Dryer

Type: Kenmore front loading clothes dryer

Model: prototype

Input Voltage: 220 ~ 240 V, 60 Hz

The following list contains the specifications and calibration factors of the test equipment. The calibration factors were verified using known sources and were calculated according to the following:

Calfac = refval / outvol in Engineering Units per Volt

Calfac à Transducer sensitivity

Refval à reference value of the calibration source

Outvol à output voltage of the transducer

c) Apparatus to use with Clothes Washer

PCB Laser Tachometer

Measurement Range up to 30,000 rpm with 1 pulse per revolution

Operating Range 90 degree incidence (60 inches apart)

60 degree incidence (15 inches apart)

Excitation Voltage 18 to 30 VDC

Temperature Range 14 ~ 122 degree F

Mounting Thread 5/8-18 UNF 2A

Weight 0.85 oz

PCB Tri-axial accelerometer

Model # 356A15, Serial # 33675, 33363 and 33664

Sensitivity 100 mV/g

Measurement Range +/- 50 g peak

Output Bias Voltage 8 ~ 12 VDC

Frequency Range 2 ~ 5000 Hz +/- 5% or 1.4 ~ 6500 Hz +/- 10%

Temperature Range -65 ~ 250 degree F

Resonant Frequency >= 25 kHz

Settling Time < 5 sec within 10% of bias

Spectral Noise 5 micro g / Hz @ 100 Hz

Mounting Thread 10-32 female

Weight 0.37 oz

Calibration Factors

Serial # 33675 (at bottom of wash tub), X = 85.071 g/V, Y = 86.785 g/V, Z = 83.799 g/V

Serial # 33363 (at top of wash tub), X = 168.45 g/V, Y = 170.96 g/V, Z = 165.59 g/V

Serial # 33664 (at the cabinet), X = 171.41 g/V, Y = 170.47 g/V, Z = 173.72 g/V

PCB Load Cell

Model # 208A03,

Sensitivity 10 mV/lb

Measurement Range 500 lb compression or tension

Output Bias Voltage 8 ~ 14 VDC

Frequency Range 0.0003 ~ 36000 Hz - 5%

Temperature Range -65 ~ 250 degree F

Spectral Noise 38.7 micro lb / Hz @ 100 Hz

Mounting thread 10-32 female

Weight 0.80 oz

Calibration Factor

Serial # 5316 126.256 lbf/V

Serial # 1909 115.422 lbf/V

Model # 208A02, Serial # 9212

Sensitivity 50 mV/lb

Measurement Range 100 lb compression or tension

Output Bias Voltage 8 ~ 14 VDC

Frequency Range 0.001 ~ 36000 Hz - 5%

Temperature Range -65 ~ 250 degree F

Spectral Noise 9.6 micro lb / Hz @ 100 Hz

Mounting thread 10-32 female

Weight 0.80 oz

Calibration Factor 27.894 lbf/V

Model # 208M164, Serial # 17199

Sensitivity

Measurement Range

Output Bias Voltage

Frequency Range

Temperature Range

Spectral Noise 5 micro g / Hz @ 100 Hz

Mounting thread 10-32 female

Weight 0.37 oz

Calibration Factor 32.295 lbf/V

PCB Pressure Sensor

Model # 1505M13, Serial # 163 (at Hot Water Inlet)

Sensitivity 0.008 V/psi

Measurement Range 0 ~ 500 psi

Test Sensor Output 1 ~ 5 V

Zero Output 0.988 V

Zero Output Error 0.3% FS

Output @ Full Scale 5.007 V

Full Scale Output 4.019 V

Full Scale Output Error 0.5% FS

Calibration Factor 100 psi/V

Model # 1505M14, Serial # 164 (at Cold Water Inlet)

Sensitivity 0.008 V/psi

Measurement Range 0 ~ 500 psi

Test Sensor Output 1 ~ 5 V

Zero Output 0.994 V

Zero Output Error 0.2% FS

Output @ Full Scale 5.011 V

Full Scale Output 4.017 V

Full Scale Output Error 0.4% FS

Calibration Factor 100 psi/V

Omega Fast Response T-type Thermocouples with Self-Adhesive Backing

Model # SA1-T-72

Maximum Temperature 350 degree F

Minimum Temperature -75 degree F

Wire 30 AWG PFA Teflon coated

Omega T-type signal conditioner

Model # CCT-24-0/200C, Linearized, 0.3% accuracy

Outputs 0 ~ 10 V

Overvoltage 75 Vdc

Error 0.05 degree C @ 25 degree C ambient typical

Measurement Range 0 ~ 200 degree C

d) Apparatus to use with Clothes Dryer

Omega Fast Response T-type Thermocouples with Self-Adhesive Backing

Model # SA1-T-72

Maximum Temperature 350 degree F

Minimum Temperature -75 degree F

Wire 30 AWG PFA Teflon coated

Omega T-type signal conditioner

Model # CCT-24-0/200C, Linearized, 0.3% accuracy

Outputs 0 ~ 10 V

Overvoltage 75 Vdc

Error 0.05 degree C @ 25 degree C ambient typical

Measurement Range 0 ~ 200 degree C


e) Data Acquisition Device

HP Model 35655A (front end) capable of up to 32 channel.

38

Created by Phie Theng Lee

Michigan Technological University