Appendix EQ, Test Equipment Recommendations and Calibration
Appendix EQ
Test Equipment Recommendations & Calibration
a) Clothes Washer
Type: Fisher and Paykal top loading clothes washer
Model: GWL 11 US
Serial: UKN627345
Input Voltage: 110 ~ 120 V, 60 Hz, 7 Amps
b) Clothes Dryer
Type: Kenmore front loading clothes dryer
Model: prototype
Input Voltage: 220 ~ 240 V, 60 Hz
The following list contains the specifications and calibration factors of the test equipment. The calibration factors were verified using known sources and were calculated according to the following:
Calfac = refval / outvol in Engineering Units per Volt
Calfac à Transducer sensitivity
Refval à reference value of the calibration source
Outvol à output voltage of the transducer
c) Apparatus to use with Clothes Washer
PCB Laser Tachometer
Measurement Range up to 30,000 rpm with 1 pulse per revolution
Operating Range 90 degree incidence (60 inches apart)
60 degree incidence (15 inches apart)
Excitation Voltage 18 to 30 VDC
Temperature Range 14 ~ 122 degree F
Mounting Thread 5/8-18 UNF 2A
Weight 0.85 oz
PCB Tri-axial accelerometer
Model # 356A15, Serial # 33675, 33363 and 33664
Sensitivity 100 mV/g
Measurement Range +/- 50 g peak
Output Bias Voltage 8 ~ 12 VDC
Frequency Range 2 ~ 5000 Hz +/- 5% or 1.4 ~ 6500 Hz +/- 10%
Temperature Range -65 ~ 250 degree F
Resonant Frequency >= 25 kHz
Settling Time < 5 sec within 10% of bias
Spectral Noise 5 micro g / Hz @ 100 Hz
Mounting Thread 10-32 female
Weight 0.37 oz
Calibration Factors
Serial # 33675 (at bottom of wash tub), X = 85.071 g/V, Y = 86.785 g/V, Z = 83.799 g/V
Serial # 33363 (at top of wash tub), X = 168.45 g/V, Y = 170.96 g/V, Z = 165.59 g/V
Serial # 33664 (at the cabinet), X = 171.41 g/V, Y = 170.47 g/V, Z = 173.72 g/V
PCB Load Cell
Model # 208A03,
Sensitivity 10 mV/lb
Measurement Range 500 lb compression or tension
Output Bias Voltage 8 ~ 14 VDC
Frequency Range 0.0003 ~ 36000 Hz - 5%
Temperature Range -65 ~ 250 degree F
Spectral Noise 38.7 micro lb / Hz @ 100 Hz
Mounting thread 10-32 female
Weight 0.80 oz
Calibration Factor
Serial # 5316 126.256 lbf/V
Serial # 1909 115.422 lbf/V
Model # 208A02, Serial # 9212
Sensitivity 50 mV/lb
Measurement Range 100 lb compression or tension
Output Bias Voltage 8 ~ 14 VDC
Frequency Range 0.001 ~ 36000 Hz - 5%
Temperature Range -65 ~ 250 degree F
Spectral Noise 9.6 micro lb / Hz @ 100 Hz
Mounting thread 10-32 female
Weight 0.80 oz
Calibration Factor 27.894 lbf/V
Model # 208M164, Serial # 17199
Sensitivity
Measurement Range
Output Bias Voltage
Frequency Range
Temperature Range
Spectral Noise 5 micro g / Hz @ 100 Hz
Mounting thread 10-32 female
Weight 0.37 oz
Calibration Factor 32.295 lbf/V
PCB Pressure Sensor
Model # 1505M13, Serial # 163 (at Hot Water Inlet)
Sensitivity 0.008 V/psi
Measurement Range 0 ~ 500 psi
Test Sensor Output 1 ~ 5 V
Zero Output 0.988 V
Zero Output Error 0.3% FS
Output @ Full Scale 5.007 V
Full Scale Output 4.019 V
Full Scale Output Error 0.5% FS
Calibration Factor 100 psi/V
Model # 1505M14, Serial # 164 (at Cold Water Inlet)
Sensitivity 0.008 V/psi
Measurement Range 0 ~ 500 psi
Test Sensor Output 1 ~ 5 V
Zero Output 0.994 V
Zero Output Error 0.2% FS
Output @ Full Scale 5.011 V
Full Scale Output 4.017 V
Full Scale Output Error 0.4% FS
Calibration Factor 100 psi/V
Omega Fast Response T-type Thermocouples with Self-Adhesive Backing
Model # SA1-T-72
Maximum Temperature 350 degree F
Minimum Temperature -75 degree F
Wire 30 AWG PFA Teflon coated
Omega T-type signal conditioner
Model # CCT-24-0/200C, Linearized, 0.3% accuracy
Outputs 0 ~ 10 V
Overvoltage 75 Vdc
Error 0.05 degree C @ 25 degree C ambient typical
Measurement Range 0 ~ 200 degree C
d) Apparatus to use with Clothes Dryer
Omega Fast Response T-type Thermocouples with Self-Adhesive Backing
Model # SA1-T-72
Maximum Temperature 350 degree F
Minimum Temperature -75 degree F
Wire 30 AWG PFA Teflon coated
Omega T-type signal conditioner
Model # CCT-24-0/200C, Linearized, 0.3% accuracy
Outputs 0 ~ 10 V
Overvoltage 75 Vdc
Error 0.05 degree C @ 25 degree C ambient typical
Measurement Range 0 ~ 200 degree C
e) Data Acquisition Device
HP Model 35655A (front end) capable of up to 32 channel.
38
Created by Phie Theng Lee
Michigan Technological University