Armed Forces Retirement Home Design Build Services Request for Proposal

Gulfport, Mississippi 21 May 2007

D – ANTITERRORISM / FORCE PROTECTION

BASIS OF DESIGN

GSA’s planning and design goals are to provide a safe and secure, cost-effective site/building environment for the residents and staff of the AFRH in Gulfport, Mississippi. This facility has been designated by GSA and the AFRH Security Office as a Low-to-Medium Threat Level installation. The physical security and protective design elements identified below will provide a balanced and layered scheme to meet this level of protection to safeguard residents and protect assets.

MINIMUM PHYSICAL SECURITY REQUIREMENTS

Physical protection systems will include at a minimum:

·  Perimeter Fence around the site complex to maintain the conventional standoff distance and control access.

·  Access Control and Electronic Security

·  Closed-Circuit Television (CCTV) at external building entrances, fence, and specified internal circulation areas.

·  Access Control (Proximity detection) at primary external building doors and specified internal control areas.

·  Intercom Systems at primary external doors.

·  Intrusion Detection System (IDS) at building perimeter and specified internal areas.

·  Vehicular Control (at the first floor within the building footprint)

·  Card access control facility to permit access by pre-screened vehicles

·  CCTV, intercom, and access control,

·  Barrier gate arm/ integrated with Electronic Security Systems (ESS)

·  Crime Prevention Through Environmental Design (CPTED) methodologies developed to maintain natural sight lines and surveillance

·  Progressive Collapse Requirements (Low potential for progressive collapse method with analysis)

·  Site Security/Safety lighting – CCTV, perimeter, and pedestrian circulation areas (design to the Low – to - Medium Level of Protection).

·  Landscaping (CPTED Principles) to maintain natural sight lines and avoid landscaping that would permit concealment of criminals or obstruct the view of security personnel and CCTV

THIS PAGE NOT USED

General Services Administration D - 1 Public Buildings Service

Southeast Sunbelt Region Chapter 7 Real Estate Design and Construction