Victorian Energy Efficiency Target Amendment Regulations 2010
S.R. No. 127/2010
table of provisions
RegulationPage
RegulationPage
1Objective
2Authorising provision
3Commencement
4Principal Regulations
5Definitions
6Prescribed activities
7Certificate not to be created more than once for same product or activity
8Register of products
9Conditions and circumstances under which a certificate cannot
be created
10New regulation 10A inserted
11Schedules 16 and 18 revoked
12Data Table revoked
13New Schedules 20 to 27 inserted
SCHEDULE 20—High Efficiency Ducted Gas Heater
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 21—Lighting
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 22—High Efficiency Refrigerators And Freezers
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 23—Replacement Of Refrigerative Air Conditioner With Ducted Evaporative Cooler
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 24—Installation Of High Efficiency Television
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 25—Installation Of Energy Efficient (Low Greenhouse Intensity) Clothes Dryer
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 26—Installation Of High Efficiency Pool Pump
PART A—CRITERIA
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
SCHEDULE 27—Data Table
═══════════════
ENDNOTES
1
Victorian Energy Efficiency Target Amendment Regulations 2010
S.R. No. 127/2010
statutory rules 2010
S.R. No. 127/2010
1
Victorian Energy Efficiency Target Amendment Regulations 2010
S.R. No. 127/2010
Victorian Energy Efficiency Target Act 2007
1
Victorian Energy Efficiency Target Amendment Regulations 2010
S.R. No. 127/2010
Victorian Energy Efficiency Target Amendment Regulations 2010
1
Victorian Energy Efficiency Target Amendment Regulations 2010
S.R. No. 127/2010
The Governor in Council makes the following Regulations:
Dated: 26 October 2010
Responsible Minister:
PETER BATCHELOR
Minister for Energy and Resources
Matthew mcbeath
Clerk of the Executive Council
1Objective
The objective of these Regulations is to amend the Victorian Energy Efficiency Target Regulations 2008—
(a)to make changes to certain prescribed activities;
(b) to provide for new prescribed activities;
(c) to make provision for certain administrative matters.
2Authorising provision
These Regulations are made under section 75 of the Victorian Energy Efficiency Target Act 2007.
3Commencement
r. 3
(1)These Regulations, except regulations6(2) and11,come into operation on 28 October 2010.
(2)Regulations 6(2) and 11 come into operation on 1July 2011.
4Principal Regulations
In these Regulations, the Victorian Energy Efficiency Target Regulations 2008[1] are called the Principal Regulations.
5Definitions
(1)In regulation 4 of the Principal Regulations insert the following definitions—
"discount factor, in relation to a prescribed activity, is the factor declared under section19(4) of the Act as applying to that activity;
Equipment Energy Efficiency (E3) Committee means the Committee responsible for managing the MCE's Equipment Energy Efficiency Program;
MCE has the same meaning as it has in section 3 of the Electricity Industry Act 2000;".
(2)In regulation 4 of the Principal Regulations, for the definition of decommissionsubstitute—
"Data Table means the Table in Schedule27;
decommission means disable and render permanently unusable;".
(3)In regulation 4 of the Principal Regulations omit "Data Table means the Table in Schedule 20;".
(4) In regulation 4 of the Principal Regulations, in the definition of install—
(a)in paragraph (b)—
(i) after "regulation 6(r)"insert"or (v)";
(ii)for "purchaser;"substitute"purchaser; and";
(b)after paragraph (b) insert—
"(c) in relation to a prescribed activity specified in regulation 6(x), means the purchase of a high efficiency television evidenced by a written record of the purchase that includes the name and address of the purchaser; and
(d)in relation to a prescribed activity specified in regulation 6(y), means the purchase of a stand alone electric clothes dryer evidenced by a written record of the purchase that includes the name and address of the purchaser;".
6Prescribed activities
r. 6
(1) In regulation 6 of the Principal Regulations—
(a) in paragraph (s), for "19."substitute"19;";
(b) after paragraph (s) insert—
"(t) installing a high efficiency ducted gas heater in new residential premises that complies with the criteria specified in Part A of Schedule 20;
(u) installing lamps that comply with thecriteria specified in Part A of Schedule21 in place of incandescent lamps that do not comply with those criteria and decommissioning the non-complying lamps;
(v) installing a high efficiency refrigerator or high efficiency freezer that complies with the criteria specified in Part A of Schedule 22;
r. 7
(w) decommissioning a refrigerative airconditioner for one or more main living areas (but not a bedroom) whether or not ducted and installing a ducted evaporative cooler that complies with the criteria specified in Part A of Schedule 23;
(x) installing a high efficiency television that complies with the criteria specified in Part A of Schedule 24;
(y) installing an energy efficient (low greenhouse intensity) clothes dryer that complies with the criteria specified in Part A of Schedule 25;
(z) installing a high efficiency pool pump that complies with the criteria specified in Part A of Schedule 26.".
(2) In regulation 6 of the Principal Regulations, paragraphs (p) and (r) are revoked.
7Certificate not to be created more than once for same product or activity
In regulation 8(2) of the Principal Regulations—
(a)in paragraph (b), for "9 or 10" substitute "9, 10 or 20";
(b)in paragraph (c), for "Schedule 18." substitute "Schedule 18 or 22;";
(c)after paragraph (c) insert—
"(d)a prescribed activity involving the installation of a second high efficiency television referred to in Schedule 24;
(e)a prescribed activity involving the installation of a second energy efficientclothes dryer referred to in Schedule 25.".
8Register of products
r. 8
(1)In regulation 9(1) of the Principal Regulations after "products that"insert", if listed in the register,".
(2)For regulation 9(2) and (3) of the Principal Regulations substitute—
"(2) The register kept under this regulation must include, in relation to each product—
(a)the prescribed activity under which it may be installed;
(b)the product type, brand name, model name or number and any other relevant details sufficient to identify the product;
(c)the date on which the entry was made;
(d)if the entry is amended, details of each amendment and the date on which the amendment took effect;
(e)if the product ceases to be a product that may be installed under a prescribed activity, the date on which it so ceased.
(3)The ESC—
(a)must cause the register kept under this regulation to be available for inspection at its office; and
(b)must cause a copy of the register to be published on its website and, so far as is practicable, kept up to date; and
(c)as soon as practicable after an entry in the register is made or amended, must cause a copy of the entry as made or amended to be published on its website for 3 months after the entry is made or amended.".
9Conditions and circumstances under which a certificate cannot be created
r. 9
(1)In regulation 10 of the Principal Regulations—
(a)in paragraph (b), for "suspended."substitute"suspended; or";
(b)after paragraph (b) insert—
"(c) if the accredited person knows, or ought to know, that the prescribed activity was not undertaken in accordance with the provisions of the Electricity Safety Act 1998, the Gas Safety Act 1997, theOccupational Health and Safety Act 2004 or the Building Act 1993 or regulations under any of those Acts.".
(2)At the end of regulation 10 of the Principal Regulations insert—
"(2) For the purposes of section 17(4) of the Act,a certificate cannot be created in relation to—
(a)a prescribed activity referred to in regulation 6(p) if the prescribed activity is undertaken after 31December 2010;
(b)a prescribed activity referred to in regulation 6(r) if the prescribed activity is undertaken after 27 October 2010.".
10New regulation 10A inserted
After regulation 10 of the Principal Regulations insert—
"10A Discount factor
If a declaration of a discount factor in respect of a prescribed activity is in effect, the calculation of the carbon dioxide equivalent of greenhouse gases to be reduced by the activity as determined in accordance with Part B of each Schedule applying to the prescribed activity must be multiplied by that discount factor.".
11Schedules 16 and 18 revoked
Schedules 16 and 18 to the Principal Regulations are revoked.
12Data Table revoked
Schedule 20 to the Principal Regulations is revoked.
Note
The Data Table is amended and re-inserted as Schedule27. See regulation 13.
13New Schedules 20 to 27 inserted
r. 10
After Schedule 19 of the Principal Regulations insert—
"______
SCHEDULE 20
Regulation 6(t)
High Efficiency Ducted Gas Heater
Prescribed activity under regulation 6(t): Installing a high efficiency ducted gas heater in new residential premises that complies with the criteria specified in Part A of Schedule 20.
PART A—CRITERIA
r. 13
Item
20A Ducted gas heater certified by an accredited body to achieve a minimum 5 star rating when tested and rated in accordance with AS 4556–2000 with a minimum rated output heating capacity of 10kW as determined in accordance with AS 4556–2000 and listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the carbon dioxide equivalent of greenhouse gases to be reduced by the installation of a productreferred to in an item in Part A is determined by multiplying the abatement factor for that item by the regional factor applying to the place where the product is installed.
The following are the abatement factors and regional factors for each item in Part A:
Item
20A Abatement factor:
(a)if the product has a rated output heating capacity of not less than 10 and not more than 18kW as determined in accordance with AS 4556–2000 and has a star rating determined in accordance with AS4556–2000 of—
(i)not less than 5 and not
morethan 5·49:4·12;
(ii)5·5 or more:4·99;
(b)if the product has a rated output heating capacity of more than 18 and not more than 28kW as determined in accordance with AS 4556–2000 and has a star rating determined in accordance with AS4556–2000 of—
r. 13
(i)not less than 5 and not more
than 5·49: 4·30;
(ii)5·5 or more:5·20;
(c)if the product has a rated output heating capacity of more than 28kW as determined in accordance with AS4556–2000 and has a star rating determined in accordance with AS4556–2000 of—
(i)not less than 5 and not more
than 5·49: 5·92;
(ii)5·5 or more:7·16.
20ARegional factor:
(a)If the product is installed in metropolitan
Victoria:1·00;
(b)If the product is installed in regional
Victoria—climatic region Mild:1·00;
(c)If the product is installed in regional
Victoria—climatic region Cold:1·61;
(d)If the product is installed in regional
Victoria—climatic region Hot:0·71.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
r. 13
20A At the beginning of the day on which the installed product is first able to produce and deliver ducted gas heating.
______
SCHEDULE 21
r. 13
Regulation 6(u)
Lighting
Prescribed activity under regulation 6(u): Installing lamps that comply with the criteria specified in Part A of Schedule 21 in place of incandescent lamps that do not comply with those criteria and decommissioning the non-complying lamps.
PART A—CRITERIA
Item
21A Installation of low energy GLS (general lighting service) lamp in place of a mains voltage incandescent GLS lamp of at least 25 watts (tungsten filament type) or 18 watts (tungsten halogen type), being a product that—
(a)has a light output equivalent to the replaced lamp; and
(b)if the product is a compact fluorescent lamp, complies with MEPS in accordance with AS/NZS4847.2:2010; and
(c)if the product is a product other than a compact fluorescent lamp, meets the performance requirements for compact fluorescent lamps set out in Table 1 of AS/NZS 4847.2:2010; and
(d)achieves minimum lighting source efficacy levels of—
(i)40 lumens/watt where light output is less than 350 lumens; or
(ii)45 lumens/watt where light output is 350lumens or more and less than 650 lumens; or
(iii)52 lumens/watt where light output is 650lumens or more and less than 850 lumens; or
(iv)55 lumens/watt where light output is 850lumens or more; and
r. 13
(e)if the lamp is to be installed in a dimmable circuit, is approved by the manufacturer as suitable for such a circuit; and
(f)has a minimum manufacturer's rated lifetime of 8000hours; and
(g)has a colour temperature that is warm white (2700K to 3500K) or cool white (3500K to 4000K).
21BInstallation of low energy reflector lamp in place of a mains voltage incandescent reflector lamp, being a product that—
(a)has a light output equivalent to the replaced lamp; and
(b)meets the performance requirement for the attributes set out in Table 1 of AS/NZS 4847.2:2010; and
(c) achieves minimum lighting source efficacy levels of 25 lumens/watt; and
(d) has a minimum manufacturer's rated lifetime of 8000hours; and
(e) if the lamp is to be installed in a dimmable circuit, is approved by the manufacturer as suitable for such a circuit; and
(f)has a colour temperature that is warm white (2700K to 3500K) or cool white (3500K to 4000K).
21C Installation of low energy lamp in place of an existing 12volt halogen lamp of at least 35 watts being a product that is compatible with the type of transformer or converter used with the replaced halogen lampand that—
(a)if the lamp is to be installed in a dimmable circuit, is approved by the manufacturer as suitable for such a circuit; and
(b)has the following characteristics—
r. 13
(i)meets the performance requirements for the attributes set out in Table 1 of AS/NZS4847.2:2010; and
(ii)achieves minimum lighting source efficacy levels of 25 lumens/watt; and
(iii)has a minimum light output of 350 lumens in the forward direction; and
(iv)has a minimum manufacturer's rated lifetime of 8000 hours; and
(v)has a colour temperature that is warm white (2700K to 3500K) or cool white (3500K to 4000K); and
(vi)has a beam angle of not less than 36 degrees when determined in accordance with IEC/TR61341 Edition 2.0.
21DInstallation of a mains voltage low energy downlight fitting in place of an existing 12 volt halogen downlight fitting that uses a 12 volt halogen lamp of at least 35watts, being a product that—
(a) if the downlight fitting and lamp are to be installed in a dimmable circuit, is approved by the manufacturer as suitable for such a circuit; and
(b)uses a lamp that has the following characteristics—
(i)meets the performance requirements for the attributes set out in Table 1 of AS/NZS4847.2:2010; and
(ii)achieves a minimum lighting source efficacy of 40 lumens/watt; and
(iii)has a minimum light output of 400 lumens in the forward direction; and
(iv)has a minimum manufacturer's rated lifetime of 8000 hours; and
r. 13
(v)has a colour temperature that is warm white (2700K to 3500K) or cool white (3500K to 4000K);and
(vi)has a beam angle of not less than 36 degrees when determined in accordance with IEC/TR61341 Edition 2.0.
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the carbon dioxide equivalent of greenhouse gases to be reduced by the installation of a productorproductsreferred to in an item in Part A is determined by the sum of the figures obtained by multiplying the number of lamps installed in the premises under each item in Part A by the abatement factor for that item, by the PF multiplier for that item and by the regional factor applying to the place where the premises are situated.
The following are the abatement factors, PF multipliers and regional factors for each item in Part A:
Item
21A Abatement factor:
(a)The abatement factor for a product that achieves a minimum lighting source efficacy of—
(i)40 lumens/watt where light output is less than 350 lumens; or
(ii)45 lumens/watt where light output is 350lumens or more and less than 650 lumens; or
(iii)52 lumens/watt where light output is 650lumens or more and less than 850 lumens; or
(iv)55 lumens/watt where light output is 850lumens or more—
and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 025
2 / 10 000 or more and less than12000 / 032
3 / 12 000 or more and less than15000 / 038
4 / 15 000 or more and less than20000 / 047
5 / 20 000 or more / 063
r. 13
(b)The abatement factor for a product that achieves a minimum lighting source efficacy of—
(i)48 lumens/watt where light output is less than 350 lumens; or
(ii)54 lumens/watt where light output is 350lumens or more and less than 650 lumens; or
(iii)62 lumens/watt where light output is 650lumens or more and less than 850 lumens; or
(iv)66 lumens/watt where light output is 850lumens or more—
and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column 3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 027
2 / 10 000 or more and less than12000 / 034
3 / 12 000 or more and less than15000 / 041
4 / 15 000 and less than 20 000 / 051
5 / 20 000 or more / 069
r. 13
(c)The abatement factor for a product that achieves a minimum lighting source efficacy of—
(i)58 lumens/watt where light output is less than 350 lumens; or
(ii)65 lumens/watt where light output is 350lumens or more and less than 650 lumens; or
(iii)75 lumens/watt where light output is 650lumens or more and less than 850 lumens; or
(iv)79 lumens/watt where light output is 850lumens or more—
and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column 3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 029
2 / 10 000 or more and less than12000 / 036
3 / 12 000 or more and less than15000 / 043
4 / 15 000 or more and less than20000 / 054
5 / 20 000 or more / 072
21B Abatement factor:
r. 13
(a)The abatement factor for a product that achieves a minimum lighting source efficacy of 25lumens/watt and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column 3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 032
2 / 10 000 or more and less than12000 / 040
3 / 12 000 or more and less than15000 / 048
4 / 15 000 or more and less than20000 / 060
5 / 20 000 or more / 080
(b)The abatement factor for a product that achieves a minimum lighting source efficacy of 30lumens/watt and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column 3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 033
2 / 10000 or more and less than12000 / 042
3 / 12000 or more and less than15000 / 050
4 / 15000 or more and less than20000 / 062
5 / 20 000 or more / 083
r. 13
(c)The abatement factor for a product that achieves a minimum lighting source efficacy of 36lumens/watt and has a manufacturer's rated lifetime of a number of hours in the range specified, in respect of an item, in column2 of the following Table is the factor shown in column 3 of that Table in respect of that item.
Column 1Item / Column 2
Hours / Column 3
Abatement factor
1 / 8000 or more and less than10000 / 034
2 / 10000 or more and less than12000 / 043
3 / 12000 or more and less than15000 / 051
Column 1
Item / Column 2
Hours / Column 3
Abatement factor
4 / 15000 or more and less than20000 / 064
5 / 20 000 or more / 086
r. 13