Tender specification for programmable Power Supply

Programmable Power Supply SYSKON Series P 4500 - K364A

Housing: Desktop, suitable for rack-mounting

19" (447mm) x 4HU (177mm+14mm) x 501 mm (+40mm) (W x H x D)

AC mains: 3x230/400 V ~ +10 / –15 %, 47 ... 63 Hz 16-A-connection clamps Power factor correction

Electrical safety: Protection class I

Overvaltage category II for AC mains

Overvoltage category I for output and interfaces

Pollution level 2

EN 61010-1 / 2001

EMC: EN 61326-1:2006, Industrial usage

Output: Rails with drilled holes for screws M6 or M8 and diameter 4 mm Prated 4500W, Urated 60V, Irated 180A

Output electrical data: Floating output with safe electrical separation towards AC mains and interfaces;

max. allowed potential output-earth 120V

Modes: adjustable constant voltage or constant curent source with automatic sharp changeover

Setting time: 0V --> Urated 7ms; 19ms no load; full load

Urated --> 1V 70ms; 11ms no load; full load

Dynamic sink for quick fall time

Setting precision: 0,1% + 60mV

0,15% + 180mA

Setting resolution: 1mV

3,125mA

Analogue Interface: 20-pin interface with screw terminals

Auxiliary voltage, 2 x Trigger, nominal voltage set& actual voltage monitoring , nominal current set and actual current monitoring, Master-/Slave function Sense-input with autosensing and voltage reversal protection 3 x signal output (2 are floating)

Digital interface: RS-232C-Interface

USB Interface

IEC-625 / IEEE-488 interface (optional)

Codes and formats according to IEEE 488.2

Adjustable functions and parameters:

Voltage (nominal & high/low limit), Current (nominal & high/low limit) Output on/off

over voltage protection level (with/without switch-off, delay time) over current protection level (with/without switch-off, delay time)

Mains power on options: reset, recall, standby

Lockable front elements (per hand, Trigger, digital)

Trigger function: optocoupler

selectable trigger action

Trigger action: output on/off, sequence start/stop

recall of saved settings

Locking of front elements

Memory: 1700 parameters and 15 complete set-ups can be saved

Accessable information: Measuring of output voltage, current and power Extremal value memory

Sequence function: Generation of voltage and current curves with up to 1700 setting points Sequences can be chained

Including DaKKs calibration certificate

Interface accessory

IEEE488 Interface, insertable, order no. K384A

Brand: Gossen Metrawatt

Country of Origin: Made in Germany

Manufacturer: GMC-I Messtechnik GmbH

Südwestpark 15

D-90449 Nürnberg

Tel.:0911-8602-111; FAX 0911-8602-777

E-Mail:

www.gossenmetrawatt.com