Comfort. By Design

GD-DE10M/12M

DEHUMIDIFIER

USER MANUAL

SAFETY INFORMATION

  1. Please read the user manual carefully before using your dehumidifier for the first time and retain for future reference.
  2. Never immerse the appliance in water or other liquids.
  3. Do notturn on the applianceif the wires or connectorsare damaged, if the appliance was inclined, after appliance malfunction or other damages.
  4. Ensure repairs are only done by a qualified service agent.
  5. Unplug the unit from main power when not in use and before any maintenance or cleaning,
  6. Operate only at the voltage specified on thedata plate.
  7. Household use only.
  8. Do not place heavy objects on the appliance.
  9. To prevent waterspillage, empty the water tank before relocating the appliance.
  10. Do not tip the appliance, as escaping water could damage the appliance.
  11. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised when using the appliance.

13.When the supply cord is damaged,it must be replaced by a qualified service agent.

14.The unit should be installed at minimum distant of 50CM from the wall or other obstacle.

OPERATING INSTRUCTIONS

  1. Handle
  2. Air Outlet
  3. Control panel
  4. Front panel
  5. Water tank
  1. Filter net
  2. Air inlet
  3. Consecutive outfall
  4. Back panel

CONTROL PLATE DESCRIPTION

OPERATION INSTRUCTION

Starting the unit

1. Plug in the dehumidifier.

2. Press the “POWER”button.

Turning off the unit

Press the “POWER” button to cut off the power supply to stop operation,

PRECAUTIONS

  1. Drain the water from the water storage tank when the tank is full,(the water level indicationlampwill illuminate). Replace the empty water tank back to its position, so the unit can resume operation.
  2. When the unit stops, to protect the compressor from damage, wait for 3 minutes before restarting.The compressor has a 3 minute delay protection.
  3. The operation temperature range for our product is 5° to35°.
  4. If the dehumidifierdoes not turn on or stops operation suddenly, check the plug and power supply to see if there are any poor connections. If the plug and power supply are in normal condition, wait for 10 minutes and restart the unit.If it still does not operate in 10 minutes, please contact your local qualified service agent.
  5. When the dehumidifier is in operation,the compressor will produce heat and make the room temperature warmer.

DRAINAGE INSTRUCTION

The extracted water can be collected by water tank, or drained

Continuouslywith a PVC hose (not supplied with this unit):

USE OF WATER TANK:

When the water drain mouth is plugged, the water willautomatically run to the water tank.

When the tank full indicator illuminates,the compressor and thefan will stop operating, please empty thewater tank:

  1. Remove the water tank as Fig 1. andempty it.
  2. Insert the water tank into its original position.

CONTINUOUS DRAINAGE

  1. Cut off the water outlet blocking behind the panel with forceps.

2. Insert a PVC Water drainage pipe of 18mm I.D. in the

drainage hole and connect it to the drainage mouth at

the front of the unit.

Filter Removal

•Grip the filter handle and slide it out fromthe back of the appliance.

•Every 2 weeks, remove the filter and clean it with warm water, below 40°C.Allow it to drynaturally and then replace.

Maintenance Instruction

1.Place the unit on a flat stable surface.

2.To avoid occurring hazard or malfunction, do not insert foreign objects into the unit.

3.When not in use for a long period of time, pull out the power cord from the wall socket.

4.For a better dehumidifying effect, the front and rear of the unit should be clear, and free from obstacleswhich will block the air flow to the unit.

5. Clean the filter every two weeks (never use alcohol, gasoline, or hot water which temperature higher than 40 degrees C.)

TROUBLE SHOOTING

The unit can not operate / ●Check that the unit is plugged in
●Water tank full lamp light? Check if the water tank is full ,if yes ,empty the tank and then place the water tank in its original position
●Check for anyforeign objects in the water tank
●Water tank not place in right position?Please take out the water tank, re-place until in the right position.
Abnormal noise of motor / ●Check if the air filter is dirty, this effect ventilation?
●Make sure the unit in on a stable surface
water leakage / ●Check If the main body of the unit is sloping
●Make sure noforeign objects are obstructing the float of the water tank

SPECIFICATIONS

MODELSPECIFICATION / GD-DE10M / GD-DE12M
POWER SUPPLY / 1∮ 220-240V~50Hz
POWER INPUT / 250W / 260W
NET WEIGHT / 11.8Kg / 12.4Kg
Water tank capacity / 1.5L
MOISTURE REMOVAL liter/day / 10 liters/day 30℃ RH 80% / 12 liters/day 30℃ RH 80%
CABINET DIMEMSION / 310Wx210Dx490H
TEMP. RANGE FOR USE ℃ / 5°~35°

(CE) N 842/2006:
R134A is a kind of fluorinated greenhouse gases covered by
the Kyoto Protocol.
Its total global warming potential (GWP) is 1300

Glen Dimplex Australasia Ltd

38 Harris Road, East Tamaki

Auckland, NEW ZEALAND

Tel: 0800 666 2824 Fax: 09 274 8472