OUTSULATION®RMD SYSTEM™ ORDERING CHECKLIST

Sold to: / Ship to:
Acct #:
Date:
Date Required:
Phone #:
Shipping Instructions: / Cust P.O. #:
Via: / Contract #:
Delivery Phone: / Project #:
Check One: / Check One: / Finish to Match? / Yes / No

New

/ Commercial / Match to:
Retrofit / Institutional / Project Name:
Both / Industrial / Owner Name:
Residential

Drainage Medium:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity

Backstop® NT1 or Sheet Water-Resistive Barrier2 or Tyvek® StuccoWrap3

/ N/A
AquaFlash®4 / N/A
AquaFlash Mesh5 / N/A
Dryvit Flashing
Tape™ 6 / N/A
Dryvit Flashing Tape Surface Conditioner™ 7 / N/A
Dryvit Drainage Mat8 / N/A

(Packaged in a 39" by 250" roll and is approximately 1/8" thick. It is fastened to the wall using 1/2 inch staples spaced 12" vertically by 16" horizontally over sheet water-resistive barriers so that the "V" pattern is oriented vertically)

Vinyl Starter Track with Drip Edge / N/A

(10 lin. ft./piece - this item is ORDERED BY THE DISTRIBUTOR FROM PLASTIC COMPONENTS. This track is used at the base of the wall, rake of the roof, and above the deck ledger board as an option vs. back wrapping. Be sure to order track according to the foam thickness being used)

Vinyl Starter Track without Drip Edge / N/A

(10 lin. ft./piece - this item is ORDERED BY THE DISTRIBUTOR FROM PLASTIC COMPONENTS. This track is used at the head of all horizontal expansion joints, window heads, and door heads as an option vs. back wrapping. Be sure to order track according to the foam thickness being used)

Dryvit Drainage
Strip™ 9 / N/A

Insulation Board:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity

EPS

/ 8

(Thickness of insulation board shall be a minimum 1" – Systems 1,2,4, and 5. System 3 requires a minimum 1 ½” thickness. Projects in high wind load areas will require special consideration.)

Mechanical Fasteners:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Wind-Lock Wind-Devil or Wind-Devil 2, or ITW Buildex Grid-Mate™ PB and Grid-Master washer / N/A

Approved Fasteners N/A

(Corrosion resistant screws or masonry anchors sized according to foam thickness and the substrate to which it is being attached)

Adhesive10:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Primus® or Genesis® / N/A

(Refer to Product Data Sheet for further information)

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Primus® DM, Genesis® DM, Genesis® DMS, Rapidry DM 35-50 or Rapidry 50-75 / N/A

(Refer to Product Data Sheet for further information)

1

Base Coat11:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Genesis®, Primus, Primus DM, Genesis DM, Genesis DMS, Rapidry DM 35-50, Rapidry 50-75 / N/A

Reinforcing Mesh:

Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Corner Mesh – 9 1/2" / N/A

(50 lin. yds)

Detail Mesh® - 9 1/2" / N/A

(50 lin. yds.)

Intermediate Mesh / 300

(25 lin. yds.)

Panzer® 15 - 48" / 300

(25 lin. yds.)

Panzer 20 - 48"
/ 300

(25 lin. yds.)

Standard Mesh - 48"
/ 600

(50 lin. yds.)

Standard - 72"
/ 900

(50 lin. yds.)

Standard Plus Mesh - 48" / 600

(50 lin. yds.)

Outsulation RMD Finish: / Color:
Product / Approx. Sq. Ft. Coverage / Unit Pricing / Quantity
Quarzputz® / 130
Sandblast® / 140
Freestyle® / varies with texture
Sandpebble® / 120
Sandpebble Fine / 150
Color Prime™ / 1400-1600

NOTE:

*All Dryvit finishes are acceptable for use with the Outsulation RMD System.

*All product coverages are estimates. Some coverage rates could vary depending upon waste, environmental conditions at the time of application and job design. Coverage rates for each product should be determined when the job site mock-up is completed. The mock-up requirements must be followed, especially when a specialty finish is used.

*All finish orders of the same color for the same project should be placed all at once to insure maximum color consistency.

*Be sure to order all additional required finish products such as Color Prime and SealClear™ when needed. Color Prime or Demandit® is required for all sealant joint surfaces.

*Dryflex® should be used on all sills, parapets and other sloped surfaces.

*A Builder's Reference Guide(DS504) should be given to the builder, owner and applicator as soon as the material order is placed. Do not assume the applicator will give this information to the builder and the owner. Remind the applicator to do the pre-application inspection prior to starting the job. He should not proceed until all unsatisfactory conditions have been corrected.

1 Dryvit Grid Tape is required to be applied over all sheathing joints and inside and outside corners. One of Dryvit’s approved adhesives applied in a vertical orientation would then be utilized to attach the EPS to the Backstop NT using the appropriate notched trowel.

2 Must utilize either Dryvit Drainage Mat or Grooved Insulation Board or expanded metal lath to separate the insulation board from the water-resistive barrier. If metal lath is utilized the EPS foam would be adhered with one of Dryvit’s approved adhesives.

3Dryvit Drainage Mat is optional when installed over Tyvek StuccoWrap.

4 Utilized in conjunction with Backstop NT only to protect substrate edges at terminations, windows doors, etc.

5 Comes in 4”, 6”, and 9 inch rolls for use in conjunction with AquaFlash.

6 Sheet type flashing to be utilized in conjunction with sheet type water-resistive barriers.

7 A water-based surface conditioner and adhesion promoter for the Dryvit Flashing Tape.

8 Optional when Tyvek StuccoWrap is utilized.

9A corrugated plastic material, which provides drainage. Required when Drainage Track is not utilized with Tyvek StuccoWrap.

10 For use in attaching insulation board to Backstop NT (System 4) or expanded metal lath (System 5).

11 When installing the system with mechanical fasteners (Systems 1, 2, 3) the base coat shall be either Genesis or Genesis DM.

1- Outsulation RMD ordering checklist.doc Updated 2-9-09 JPFebruary 2009

1