Record Format Document

RT_K14_ADDTNL_METERING_DETS

Copyright Xoserve 2014©, all rights reserved.

No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / Xoserve
Owner: / Xoserve
Version: / 3A
Status: / Approved
Date: / 12-Dec-2014

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
2L / 4-Sep-2002 / 22-Apr-2003 / Live
3FA / 1154 / 07-Oct-2014 / 1-Oct-2015 / For approval
3A / 1154 / 12-Dec-2014 / Project Nexus Implementation Date / Approved

Notes

Note 1
OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places
Note 2
All text fields will be enclosed in double quotes ("")

Record Type Definition

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of information that this record represents.value:K14
METER_TYPE / O / T / 1 / 0 / The type of meter.
Values
R = Rotary
T = Turbine
D = Diaphragm of unknown material
L = Leather Diaphragm
S = Synthetic Diaphragm
U = Ultrasonic
Z = Unknown
METER_MODEL_NAME / O / T / 10 / 0 / DEFINITION: The model type of the meter e.g. U6, U16, 102M12. When there is no meter present the field will be set to UNKNOWN.The model description for the
meter e.g. "U6", "U16", "102M12" or "G2500”
METER_MANUFACTURER_CODEMETER_MANUFACTURER / O / T / 3 / 0 / The code of the manufacturer of the meter.
METER_MANUFACTURED_YEAR / O / N / 4 / 0 / The year in which the meter was manufactured expressed as a century date (e.g. 1981).
IMPERIAL_METER_INDICATOR / O / T / 1 / 0 / Indicator identifying if the meter measures volume of gas consumed in metric or imperial units.
Allowable values when present:-
Y = Imperial meter
N = Metric meter
METER_READING_UNITS / O / N / 5 / 0 / This contains the units the meter is read in e.g. 10,100, 1000 Cubic Feet
CONVERTOR_MODELCORRECTOR_MODEL_NAME / O / T / 10 / 0 / Convertor model nameThe model description for the meter (e.g. "U6", "U16", "102M12" or "G2500").
CONVERTOR_MANUFACTURERCORRECTOR_MANUFACTURER / O / T / 3 / 0 / Short code version of the Convertor manufacturer’s name.The code of the manufacturer of the corrector.
CONVERTOR CORRECTOR_MANUFACTURED_YEAR / O / N / 4 / 0 / The year in which the convertor meter was manufactured expressed as a century date (e.g. 1981).
CORRECTED_READING_UNITSCORRECTOR_CORRECTED_READING_UNITS / O / N / 5 / 0 / This contains the units the corrected convertor corrector reading reads in, e.g. 10s, 100s, 1000s cubic feet.
UNCORRECTED_READING_UNITSCORRECTOR_UNCORRECTED_READING_UNITS / O / N / 5 / 0 / This contains the units the uncorrected corrector convertor reading is reads in, eg 10s, 100s, 1000s.cubic feet.
Total / 24 54

RT_K14_ADDTNL_METERING_DETSPage 1 of 4Issue Date: 12/12/2014

Version: 3 A Implementation Date:Project Nexus Implementation Date