23-02-2016

Quotations are invited for “Plant Growth Chamber”

Sealed quotations clearly marked “Plant Growth Chamber ” in two separate bids "Technical and Price offer" along with terms and conditions, warranty should be addressed to:
The Procurement Manager
ICGEB
ArunaAsaf Ali Marg,New Delhi 110 067

Quotations must reach latest by "01-03- 2016’’

Specifications of Plant Growth Chamber:

  1. Machine should have a Microprocessor PID Control providing high precision in temperature, relative humidity and illumination control for uniform and stable growth environment.
  2. Growth chamber should have a 10 step program with PC interface controller providing automatic operation of various programmed cycles and maximum 999 cycles.
  3. Growth chamber should have capacity 800 to 1000 liters. The outer width of the instrument should not exceed 1600 mm and the height of the growth chamber should not exceed 2100mm.
  4. The growth chamber should have interior stainless steel 304 and exterior Epoxy powder coated EGI steel.
  5. Growth chamber should have internal shelf area of at least 0.50 m2 x 4 shelves.
  6. Temperature range 0 to 60 oC (light off) and 10 oC to 60 oC (light on) with set accuracy ±0.10°C.
  7. Growth chamber should have humidity range 30% to 98% with uniformity of ± 2-3% at 60 %
  8. RH by evaporation by fan with heater. The growth chamber should have the provision for up gradation to ultrasonic humidifier. The price for the ultrasonic up- gradation should be clearly mentioned.
  9. Growth chamber should have illumination range 0 to 25000 Lux. The growth chamber should have under shelf lighting, with 5 LED lamps on each shelf and total 4 such shelves should be accommodated inside the chamber. The controller should provide the facility for programmable lighting control for all the shelves.
  10. Growth chamber should have lamp – on – Delay System protect plants from stress by preventing sudden change of light strength and turning on / off light control.
  11. Growth chamber should have double door structure with tempered safety glass door with silicon packing and outer should have a magnetic packing on the front door.
  12. Growth chamber should have an optional provision for data logging system which can log data for light, temperature, and humidity in graphical form and should be easy to connect to PC.
  13. Growth chamber should have all safety features – high & low temp. Protector, over current & leakage breaker.
  14. Electric supply 220 V 50Hz
  15. Machine should come with atleast 5 years warranty from the date of installation.
  16. Machine should be accompanied with an compatible online UPS system for atleast 1 hour battery backup support.