CURRICULUM VITAE

THAVAMANI NAGESH

Kremenco- E-025

Po-Box- 52480

Al- Riqqa-53465

Kuwait.

Mobile No- 00965-66342457

Post Applied For: ElectricalSupervisor

Total Experience:Seventeen (18.3) Years

Personal Profile

Father’s Name:K. Thavamani

Date of Birth:02-June-1971

Nationality:Indian

Marital Status:Married

Permanent Address:Gollamadugu (Village),

Bommasamudram (Post),

Gudipalamandalm,

Chittoor (Dist),Pin- 517132,

Andhra Pradesh,SouthIndia.

Mail Id:

:

Contact No:00965- 66342457

Languages Known:English, Tamil, Telugu and Hindi

Passport Details

Passport No / Date of Issue / Valid Up to / Place of Issue
G 0639752 / 23-02-2007 / 22-02-2017 / Kuwait

QUALIFICATION DETAILS

Technical Qualification

Course / Name of Institution / Board / University / Year of passing
Diploma in Electrical Engineering / IETA Mumbai, India. / Institute of Engineering Technician Association, Mumbai, India / Jan-1995
National Trade Certificate Electrical / Sri Renugambal ITI,
Polur, Tamil Nadu,India. / Industrial Training Institute / July-1991
National Apprentice Certificate / BHEL Ranipet, Tamil Nadu, India. / Electrical Trainee / Oct- 1995
Diploma in Industrial Safety / National Institute Of Labour Education and Management
Tamil Nadu,India. / Industrial Safety / Oct-2004

EDUCATIONAL QUALIFICATION

Course / Name of Institution / Board / University / Year of passing
Bachelor of Business Administration / MadrasUniversity, Tamil Nadu, India. / Universityof Madras. / May-1999
School Secondary Certificate / PCRGovtJunior College,AndhraPradesh,India. / Board Of Secondary Education, Andhra Pradesh. / Oct-1988

Computer

  • Having Knowledge of MicrosoftOffice XL, Power Point, Windows Word document,MMMS and internet.

Other Certificates

  • Suggestion award Certificate Issued By BHEL LTD, Ranipet, Tamil Nadu, India.
  • Electrical License ‘B’ # 53598 Issued by TNEB, Tamil Nadu,India.
  • Electrical Safety and work Permit System course Attended by Equate Petrochemical Company.Kuwait.
  • Work Permit System Course Attended by Kuwait Oil Company (KOC) Safety Department And Holding Executing authority Card for all Type Of Work Permits
  • Electronic work Permit System Course Attended By Kuwait Oil Company safety Department and Holding Executing authority card for all Type of Work Permit System

Employment Details inIndia and Abroad

Sl.No / Employer / Position Held / Duration
1 / Kuwait Oil Co.(KSC), Kuwait, Seconded by Kuwait industrial Refinery Maint & Engineering Company, KREMENCO-KUWAIT. / Senior Electrical Technician / From Sep 2006 to till date(Maintenance)
( 4 years )
2 / Equate Petrochemical Co, Kuwait Seconded by Kharafi National Co, Kuwait. / Electrical Supervisor / From March 2006 to April 2006 (Turn around Job)-
( 0.2 Month )
3 / Kuwait Oil Co.(KSC), Kuwait Seconded by Al-Meer Technical Services Company-Kuwait. / Lead Electrician / From July 1999 to Sep 2005 (Maintenance)
( 6.3 years)
4 / Bharat Petroleum Corporation Limited (BPCL), India Seconded By Senthil Techno Crafts. Chennai, India. / Senior Electrician / From Nov’ 1995 to May 1999 ( Project and Maintenance)- ( 3.8 years )
5 / Indian Oil Corporation Limited (IOCL), India Seconded by Yes Jay Engineering, Chennai, India. / Electrician / From Aug’ 1991 to Sep’ 1994 (Project and maintenance)- ( 3.0 years)
6 / Bharat Heavy Electricals Limited(BHEL), Ranipet, India / Electrical Trainee / From Oct 1994 to Oct 1995
( 1.0 Year )

Working Experience in India and aboard

  • 18.3Years Experience in Electrical Project and Maintenance Work

Aboard / 10.5 years
India / 7.8 years

Nature of Works

  • Operation , Maintenance And Troubleshooting Works For All Kinds Of Electrical Equipments In Kuwait Oil Company ( KOC ), Crude Oil Gathering Center, Gas Booster Station , Water Treatment Plant, Water Injection Plant, Oil Wells, Oil Rigs, Power Plants, And Field Distribution,
  • Shutdown Maintenance Of Equate Petrochemical Plant In Kuwait
  • Erection, Commissioning And Testing Of All Kinds Of Electrical Equipments In Bharath petroleum gas plant ( BPCL ) , Indian oil corporation( IOCL ) and Bharath Heavy Electrical Ltd ( BHEL )
  • Working With Following Electrical Drives, System and Controls.

Power And Distribution Transformer

Generator

HV, MV, Switch Gears and Panels

HV, MV and LV Motors

 HV,MV and LV Power and Control Cables & Glanding

MCC Panels and Motor Starter

 Protection Relays

Grid Ear things

VSD Motors

 CT and PT

Batteries and Battery Chargers

UPS System

Power and Control Circuit

Industrial Lightings

PDB and LDB

 MOV and ROV

 DCS and PLC

Cathode Protection Rectifier (CPR)

 Fire and Gas

 Heat Tracing Cables for Inst valves and pipe lines

 Electrical Testing Equipments

 Hazardous Area Classification and PTW

 Plant Start up and Shut down Activities

Page 1 of 5

WORKING EXPERIENCE IN INDIA AND ABROD

Maintenance Background:- Carried Out Day By Day Preventive, Corrective And Break Down Maintenance Activities On Electrical Systems, Plant And Equipments Assigned Field Covering Gas Turbine, Generators And Controls, LV/H.V Motors And Control Circuits, Transformers, MVSG, HVSG, Cables, H.V Overhead Lines, Electrical Submersible Pumps, VSD Motors, UPS System, Batteries And Battery Chargers, Desaltor, Lightings, Condensate Recovering Unit, Substations For Performing Most Of The Maintenance Activities.

To Perform Troubleshooting, Identifying, Isolating, Repairing and Testing Of Faulty Electrical Components and Circuits. To Respond To Emergency Call Outs, Troubleshooting the Problem and Take Action To Ensure The Correct Operation Of The Electrical Equipments

Liaising With Counter Parts in Maintenance and Operations to Release Desired Equipment and Plant and Executing Work on Site and or in Workshop.

To Comply with All Company Health, Safety and Environment As well As Work Permit, Policies And ProceduresMaintain Effective Performance Measures for all Plant control and supervisory Systems and Maintaining the Spares, History of the Equipments, Updating the Drawings, Jobs modification with new and existing systems.

Reporting of Hazardous and Near Miss to HSE Department. And regularly Participate In HSE Programmed, quiz and Safety Suggestion.

ELECTRICAL SYSTEM ISOLATION: - Carried out Electrical System isolation and De-Isolation for Log out, Tag out and Multi lock System for Operation, Instrument, Mechanical, and Electrical as Per HSE policies and Maintain log Book.

TRANSFORMER: - Installation, Commissioning, Testing, Maintenance and Troubleshooting of 33/11Kv,11kv/3.3Kv,11kv/0.440kv Indoor and outdoor type Up to 5MVA Power Distribution Transformer ABB, FG Wilson, Vijay Electrical, Siemens, GE, Lucy, Betra, Emirates transformer , Agecelec and AL-Ahleia.

GENERATOR’S: - Installation, Commissioning, Testing, Maintenance, and Troubleshooting of Generators, Control Panel Parameters, Automatic Changeover Switch, Mechanical Changeover Switch Interlocking system, AVR and alternators up to 5MVA Cater Filler, GE, Perkins, Kirlosker, FG Wilson, and General Electrical Companies.

H.T AND L.T MOTORS:- Installation, Commissioning, Testing, Overhauling, Maintenance and Troubleshooting of H.V, MV,LV Motors, Breakers, DOL and Star Delta Starter UP to 2MW for Siemens, GE, ABB. Laurence Scott, Brook Crompton, English electric, AL-Ahleia and Ebomac.

HV, MV and LV POWER AND CONTROL CABLES & GLANCING: - Cable Laying, Glancing, Testing , loop Checking, Termination and using Cable Lugs of cables up to 400 sq mm, MICC, PVC, XLPE, PILC, Multi Core and Single Core Cables all Type of Company’s

CT AND PT: - Installation, Testing Maintenance of CT, VT, and PT for Measuring and Protection Relays of Feeders, Transformers, Generators and Motors.

BATTERIES AND BATTERY CHARGERS: - Installation, Commissioning, Testing, and Maintenance of Batteries, and Battery Chargers for Lead Acid Battery and Alkaline Battery for Cat, Soft, Knife, HBL, Energy and Chloride.

UPS SYSTEM:- Installation, Commissioning, Testing, Maintenance and Troubleshooting of UPS up to 100KV,440v/ 110v, 230v/110v Control Supply for HT & LT

Substation Panel’s Boards, Instruments Control Panels PLC & DCS Systems, for Soft, Chloride, Gutter, Powernectic and Knife Companies.

CPR: - Operation, Maintenance and Troubleshooting of Cathodes Protection Rectifier Anode and Cathode AC to DC Rectifiers Transformer Using Pipelines and vessels for avoid corrosion.

EARTHLING SYSTEMS: -Installation Commissioning, Testing and Maintenance of all Type of Grid Earthing Network for all Electrical Equipment Vessels, Tanks and Neutral Earthing and Testing and Measuring of Resistance values.

LIGHTINGS: - Erection, Commissioning, Testing Maintenance and Trouble Shooting of All Types of Lighting’s, Tower Light, Street Light for Industrial and Office’s. In Hazard’s Area Explosion Proof Light Fittings S.V, M.V, Metal Alloyed, Halogen, Emergency light fitting’s Lighting Set Generator Set and Using Lux Meter.

PROTECTION RELAYS:- Motors, Transformers, Generators, Feeders, all types of Relays, Over Current, Earth Fault, Restricted Earth Fault, Stalling, Over Load , Thermal over Current Relay, Winding Temperature Relay Commissioning and Testing with InjectionTest Kit.

ELECTRICAL TESTING EQUIPMENT:- Using of Mugger, AVO Meter, Cable Route Locator, Fault Locator, Burning kit, Hi-Pot Test Kit, Secondary Injection Test Kit, Earth Mugger, Phases Sequence Meter, Taco Meter, Phasing Stick, Earth Stick, all type of Electrical Equipments Testing in hazardous area using intrinsically safe meter used.

ZONE CLASSIFICATION: -Zone 0, Zone 1, Zone 2, Temperature Classification, Obtain Safe Work Permit Cold, Hot, Vehicle, Vessel, EX and EXD Explosion.Propos

DRAWINGS: - Reading Power and Control Circuit for MCC panel, Motors, Switchgear Control Paneland Substation & Ring Main Unit.

PLANT START UP AND SHUT DOWN SEQUENCE.Trouble Shooting Of Heat Transfer Units, Boiler, Compressor, Super Heaters, Desalted Plant, Motors, Condensate Requiring Unit and Gas Turbine.

DECLARATION

Hereby, I Declare That All The Above – Mentioned Information Is Correct And True To The Best Of My Knowledge.

SIGNATURE

(T. NAGESH)

Page 1 of 5