SECTION 09900
PAINTS AND COATINGS
** NOTE TO SPECIFIER ** Rodda Paint; Paints and Coatings.
.
This section is based on the products of Rodda Paint, which is located at:
6107 N. Marine Dr.
Portland, OR 97203
Toll Free Tel: 800-452-2315
Tel: 503-737-6033
Fax: 503-737-6004
Email: request info ()
Web: www.roddapaint.com
[ Click Here ] for additional information.
Rodda's strength is its diversity of product and its dedication to the commercial, industrial and coatings application markets. Rodda Paint has the Northwest's largest selection of product offerings for both the professional user and the do-it-yourself homeowner.
Our extensive product offerings, our technical expertise, and our highly skilled customer service staff offer unmatched support for architects, designers, builders, painting contractors, property managers, large industrial coatings users, and today's demanding consumers.
With 53 stores in Alaska, Idaho, Montana, Oregon, and Washington, Rodda Paint Company is close to major commercial centers throughout the Northwest. Please feel free to contact us with any questions or for information about your coating req'ts.
See our SpecWizard: Click Here
PART 1 GENERAL
1.1 SECTION INCLUDES
** NOTE TO SPECIFIER ** Delete items below not required for project.
A. Surface preparation and field painting of exposed exterior items and surfaces.
B. Surface preparation and field painting of exposed interior items and surfaces.
C. Surface preparation and field painting/sealing of Specialty Surfaces that do not have factory-applied final finish.
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
A. Section 05500 - Metal Fabrications.
B. Section 06200 - Finish Carpentry.
C. Section 07100 - Dampproofing and Waterproofing.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
A. ANSI A13.1 - Scheme for the Identification of Piping Systems.
B. ANSI Z535.1 - Safety Color Code.
C. ASTM D 16 - Standard Terminology Relating to Paint, Varnish, Lacquer, and Related Products.
D. ASTM D 3359 - Standard Test Methods for Measuring Adhesion by Tape Test.
E. ASTM D 1653 - Standard Test Methods for Water Vapor Transmission of Organic Coating Films.
F. ASTM E-96 - Standard Test Methods for Water Vapor Transmission of Materials.
G. ASTM D 412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension.
H. 40 CFR 59, Subpart D National Volatile Organic Compound Emission Standards for Architectural Coatings.
I. Fed Spec - TT C-555B - Wind Driven Rain Test.
J. SSPC, The Society for Protective Coatings - Web Site http: www.sspc.org :
1. SSPC-SP1 Solvent Cleaning.
2. SSPC-SP2 Hand Tool Cleaning.
3. SSPC-SP3 Power Tool Cleaning.
4. SSPC-SP6 Commercial Blast Cleaning.
5. SSPC-SP7 Brush-Off Blast Cleaning.
K. PDCA Paint and Decorating Contractors of America - Web Site http://www.pdca.org:
1. PDCA Standards P1 through P15
1.4 SUBMITTALS
NOTE TO SPECIFIER ** Delete references, such as LEED req'ts, from the list below that are not actually required by the text of the edited section.
A. Submit under provisions of Section 01300 - Administrative Requirements
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods.
C. Finish Schedule: Submit finish schedule including color information, gloss and model number for each type and color of finish specified.
D. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten years experience.
B. Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of five years demonstrated experience in installing finishes and coatings of the same type and scope as specified.
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1. Finish areas designated by Architect.
2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
3. Refinish mock-up area as required to produce acceptable work.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
B. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
C. Take special safety precautions against hazards from toxic and flammable materials.
D. Place paint and solvent contaminated cloths and materials, subject to spontaneous combustion, in containers and remove from job site each day.
E. Keep open flame, electrical and static spark, and other ignition sources from flammable vapors and materials at all times.
1.7 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.
B. Post "WET PAINT" signs during application and curing of all coatings that may be accessed by other trades or the public.
C. Post "NO SMOKING" signs during application and curing of solvent-based materials.
1.8 COORDINATION
A. Coordinate Work with other operations and installation of finish materials to avoid damage to installed materials.
B. Do not apply coating materials until moisture or dust-producing work or other appearance or performance impairing construction activities have been completed.
1.9 WARRANTY
A. At project closeout, provide to Owner or Owners Representative an executed copy of the manufacturer's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.
1.10 EXTRA MATERIALS
A. At project closeout, provide to the owner or owners representative, two gallons (7.75L) of each finish coating material in sealed 1 gallon (3.875 L) containers, clearly marked with color and finish identification.
B. Custom Colors: Provide a list of color formula and location for each finish specified.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Rodda Paint, which is located at: 6107 N. Marine Dr.; Portland, OR 97203; Toll Free Tel: 800-452-2315; Tel: 503-737-6033; Fax: 503-737-6004; Email: request info (); Web: www.roddapaint.com
1. Architectural Representative: Jeff McIntyre: Phone: (206) 396-7074. E-mail: .
2. Seattle Sales Office: 3838 Fourth Ave. South, Seattle, WA 98134. Phone: (206) 652-0445. Fax: (206) 652-0565.
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with req'ts of Division 1 section on product options and substitutions.
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of 01600 - Product Requirements.
2.2 PAINT MATERIALS - GENERAL
** NOTE TO SPECIFIER ** Typically retain this requirement.
A. VOC : Provide materials to meet EPA 40 CFR Part 59 (AD-FRL-6149-71] RIN 2060 - National Volatile Organic Compound Emission Standards for Architectural Coatings, Final Rule, Federal Register / Vol. 63, No.176, September 11, 1998/Rules and Regulations.
** NOTE TO SPECIFIER ** Delete if LEED certification not required.
B. LEED v3.0 NC, CI, or CS IEQ 4.2: Low-Emitting Materials - Paints and Coatings Compliance
1. Paints and coatings used on the interior of the building (i.e., inside of the weatherproofing system and applied onsite) shall comply with the following criteria as applicable to the project :
a. Architectural paints and coatings applied to interior walls and ceilings shall not exceed the volatile organic compound (VOC) content limits established in Green Seal Standard GS-11, Paints, 1st Edition, May 20, 1993.
1) Flats: 50 g/L.
2) Non-Flats: 150 g/L.
b. Anti-corrosive and anti-rust paints applied to interior ferrous metal substrates shall not exceed the VOC content limit of 250 g/L established in Green Seal Standard GC-03, Anti-Corrosive Paints, 2nd Edition, January 7, 1997.
c. Clear wood finishes, floor coatings, stains, primers, and shellacs applied to interior elements shall not exceed the VOC content limits established in South Coast Air Quality Management District (SCAQMD) Rule 1113, Architectural Coatings, rules in effect on January 1, 2004.
** NOTE TO SPECIFIER ** Delete paint systems not required. Paint complying with LEED req'ts are specified in Par. 2.3B.
2.3 EXTERIOR PAINT SYSTEMS
A. Exterior Metal:
1. Substrate: Ferrous Metal Structural Steel.
** NOTE TO SPECIFIER ** Select primer. Delete one of the next two paragraphs.
a. Primer: Ferrous Metal Surfaces - Prime exposed metal areas with one coat 708225 Barrier III High Solids Alkyd Metal Primer. (solvent based)
b. Primer: Ferrous Metal Surfaces - Prime exposed metal areas with one coat 508901 Metal Master Primer (Waterborne).
** NOTE TO SPECIFIER ** Select top coat based on finish. Delete eight of the next nine paragraphs.
c. Finish: Gloss, Silicone Alkyd Gloss - Two coats Rodda 758801 Powerkote Silicone Alkyd Enamel.
d. Finish: Semi-Gloss, Acrylic - Two coats Rodda 548901 Multi Master DTM Self Crosslinking Semi-Gloss Enamel.
e. Finish: Satin, Acrylic - Two coats Rodda 528901 Multi Master DTM Self Crosslinking Satin Enamel.
f. Finish: Gloss, Acrylic - Two coats Rodda 552001 Unique II Acrylic Enamel Gloss.
g. Finish: Semi-Gloss Acrylic -Two coats Rodda 542001 Unique II Interior/ Exterior Semi-Gloss.
h. Finish: Low Gloss Acrylic -Two coats Rodda 532001 Unique II Interior/ Exterior Low Gloss.
i. Finish: Low-Gloss Acrylic -Deep Colors and Accent Striping: Two coats Rodda 53203x Color Base System Exterior.
j. Finish: Gloss, Alkyd Gloss - Two coats Rodda 758101 All Purpose Equipment Enamel.
k. Finish: Semi-Gloss, Alkyd Semi-Gloss - Two coats Rodda 745001 Porsalite Semi-Gloss.
2. Substrate: Ferrous Metal: Windows, Frames, and Doors
** NOTE TO SPECIFIER ** Select primer. Delete one of the next two paragraphs.
a. Primer: Ferrous Metal Surfaces - Prime exposed metal areas with one coat 708225 Barrier III High Solids Alkyd Metal Primer. (solvent based)
b. Primer: Ferrous Metal Surfaces - Prime exposed metal areas with one coat 508901 Metal Master Primer (Waterborne).
** NOTE TO SPECIFIER ** Select top coat based on finish. Delete eight of the next nine paragraphs.
c. Finish: Gloss, Silicone Alkyd Gloss - Two coats Rodda 758801 Powerkote Silicone Alkyd Enamel.
d. Finish: Semi-Gloss, Acrylic - Two coats Rodda 548901 Multi Master DTM Self Crosslinking Semi-Gloss Enamel.
e. Finish: Satin, Acrylic - Two coats Rodda 528901 Multi Master DTM Self Crosslinking Satin Enamel.
f. Finish: Gloss, Acrylic - Two coats Rodda 552001 Unique II Acrylic Enamel Gloss.
g. Finish: Semi-Gloss Acrylic -Two coats Rodda 542001 Unique II Interior/ Exterior Semi-Gloss.
h. Finish: Low Gloss Acrylic -Two coats Rodda 532001 Unique II Interior/ Exterior Low Gloss.
i. Finish: Low-Gloss Acrylic -Deep Colors and Accent Striping: Two coats Rodda 53203x Color Base System Exterior.
j. Finish: Gloss, Alkyd Gloss - Two coats Rodda 758101 All Purpose Equipment Enamel.
k. Finish: Semi-Gloss, Alkyd Semi-Gloss - Two coats Rodda 745001 Porsalite Semi-Gloss.
3. Substrate: Aluminum.
** NOTE TO SPECIFIER ** Select primer. Delete one of the next two paragraphs.
a. Primer: Aluminum Surfaces - Prime with one coat Carboline Rustbond FC Penetrating Sealer Primer at 1.0-2.0 mils DFT.
b. Primer: Aluminum Surfaces - Prime exposed metal areas with one coat 508901 Metal Master Primer (Waterborne).
** NOTE TO SPECIFIER ** Select top coat based on finish. Delete eight of the next nine paragraphs.
c. Finish: Gloss, Silicone Alkyd Gloss - Two coats Rodda 758801 Powerkote Silicone Alkyd Enamel.
d. Finish: Semi-Gloss, Acrylic - Two coats Rodda 548901 Multi Master DTM Self Crosslinking Semi-Gloss Enamel.
e. Finish: Satin, Acrylic - Two coats Rodda 528901 Multi Master DTM Self Crosslinking Satin Enamel.
f. Finish: Gloss, Acrylic - Two coats Rodda 552001 Unique II Acrylic Enamel Gloss.
g. Finish: Semi-Gloss Acrylic -Two coats Rodda 542001 Unique II Interior/ Exterior Semi-Gloss.
h. Finish: Low Gloss Acrylic -Two coats Rodda 532001 Unique II Interior/ Exterior Low Gloss.
i. Finish: Low-Gloss Acrylic -Deep Colors and Accent Striping: Two coats Rodda 53203x Color Base System Exterior.
j. Finish: Gloss, Alkyd Gloss - Two coats Rodda 758101 All Purpose Equipment Enamel.
k. Finish: Semi-Gloss, Alkyd Semi-Gloss - Two coats Rodda 745001 Porsalite Semi-Gloss.
4. Substrate: Galvanized Metal.
** NOTE TO SPECIFIER ** Select primer. Delete one of the next two paragraphs.
a. Primer: Galvanized Surfaces - Prime with one coat Carboline Galoseal WB High Performance Wash Primer at 0.5-1.0mils DFT.
b. Primer: Galvanized Surfaces - Prime exposed metal areas with one coat 508901 Metal Master Primer (Waterborne).
** NOTE TO SPECIFIER ** Select top coat based on finish. Delete eight of the next nine paragraphs.
c. Finish: Gloss, Silicone Alkyd Gloss - Two coats Rodda 75880x Powerkote Silicone Alkyd Enamel.
d. Finish: Semi-Gloss, Acrylic - Two coats Rodda 548901 Multi Master DTM Self Crosslinking Semi-Gloss Enamel.
e. Finish: Satin, Acrylic - Two coats Rodda 528901 Multi Master DTM Self Crosslinking Satin Enamel.
f. Finish: Gloss, Acrylic - Two coats Rodda 552001 Unique II Acrylic Enamel Gloss.
g. Finish: Semi-Gloss Acrylic -Two coats Rodda 542001 Unique II Interior/ Exterior Semi-Gloss.
h. Finish: Low Gloss Acrylic -Two coats Rodda 532001 Unique II Interior/ Exterior Low Gloss.
i. Finish: Low-Gloss Acrylic -Deep Colors and Accent Striping: Two coats Rodda 53203x Color Base System Exterior.