Mansoor Javed Awan

Father’s Name: Javed Akhtar Awan

Date of Birth: Nov 06, 1980

Nationality: Pakistani

Phone: +92 333 4335662, +92 42 7833087

E-Mail:

POWER SYSTEM PROTECTION DESIGN ENGINEER

Education:

  • (2004-2006)M.Sc. Electrical Engineering

(University of Engineering & Technology Lahore. Pakistan)

1ST Division

  • M.Sc. Computer Engineering (Contiune)

(LahoreUniversity Of Management Sciences)

  • (1998-2002) B.Sc. Electrical Engineering

(University of Engineering & Technology Lahore. Pakistan)

A Grade/1st Division

  • (1995-1997) Higher Secondary School Certificate

(GovernmentCollegeLahore, Pakistan)

A Grade/1st Division (81 %)

  • (1993-1995) Secondary School Certificate

(Govt.HighSchoolAllamaIqbalTownLahore, Pakistan)

26th position in Board of Intermediate & Secondary Education, Lahore

Marks:758 (89 %)

Research and Professional Experience:

RESEARCH PUBLICATION

Nauman Zafar, Awan and Atif Nadeem(2002), “Experimenting with new methods in VoIP”, Linux Journal USA

Professional Experience

Seven years of progressively responsible experience in electrical design, Substation protection and control drawings & Schemes, testing & commissioning of substations. Strong leadership, team-building and problem-solving expertise.

Areas of expertise include:

  • Technically sophisticated professional with pioneering career reflecting strong leadership qualification coupled with valuable Electrical expertise. Maintain focus on achieving bottom line results while formatting and implementing advanced technology and business solutions to meet a diversity of needs.
  • Nominated for APPS 2009(23Feb-28 March)Analysis of Protection and Power System Course for five weeks offered by Areva T&D Stafford UK.
  • Design and System Engineering for 132/220/500KV Substation’s Control, Protection, Metering and CT & PT sizing.
  • Short Circuit Analysis using ETAP , Relay setting Calculation of latest numerical protection relays and Testing of Protective Relays.
  • Able to analyze the outages and malfunctioning of the system elements and suggest remedial measures to avoid re-occurrence of same event using ETAP.
  • Expertise in preparing and reviewing the protection and control schematic design and to performs technical evaluation of major equipment submittals.
  • Capable of designing the protection schemes of Thermal Power Plants and 500KV, 220KV and 132KV substationsOHTL and U/G cable protection system.
  • Able to establish pre-qualification of new protection equipment from world wide relays' Manufacturers and up dating the Relays Approved List.
  • Extensive experience in reviewing and approving the contactors' schematics for the new substations and protection modification drawings for the remote end substation ends and issuance of relay setting calculations for substations and checking of contractors' relay setting-calculations and issue of the new protection settings.
  • Strong experience in design review of technical submittals from various international contractors like M/s Siemens, M/s ABB,M/s Areva etc and implementation of these drawings at respective substations.
  • Highly self-motivated, goal oriented and a dedicated team player and safety savvy – strong focus on project risk analysis and strategic planning.
  • Strong communication skills – effectively express thoughts and ideas with customers, field personnel, vendors, management and peers

Water and Power Development Authority (WAPDA) - Largest Electric Utility Organization in Pakistan,

  • From 2002 till date as a Technical Asst.Manager in Power System Protection Department.

preparation of Interconnection and Schematic Drawings of EHV Substations:-

  • Evaluation of Tender Power Transmission Enhancement Investment Program under ADB Loan No.2289 Tender No. ADB-08-2007 for the Procurement of Control and Relay Panels and other Related Equipment for 500 & 220KV Grid Station. Six No. Bidders participated the Tender.(M/s Siemens, M/s PEL,M/s Areva, M/s ABB,M/s Sumec China, M/s Syed Bhais).
  • Preparation of Complete Interconnection & Schematic Drawings, & Cable scheduling for the following: One 250MVA , 220/132 kV AutoTransformerBay and Two 132kV TransmissionLineBays at 220kV Grid Station Dharki.
  • Inspection of 500kV and 220kV Local control cubicle Panels manufactured by M/s Siemens.
  • Preparation of Complete Interconnection & Schematic Drawings, & Cable scheduling for the following: One 450MVA , 500/220 kV Auto Transformer Bank at 500 kV Grid station Rewat.All relevant protection panels of ABB China make were used.
  • A Complete new 220 kV Grid station at Ghazi Barotha with One 160 MVA 220/132 KV Auto Transformer & two 220 kV line bays with 1½ Breaker Scheme. Siemens make Protection Panels relevant for transformer & lines were used for new system.
  • A Complete new 220 kV Grid station at Muzaffargarh with two 160 MVA 220/132 kV Auto Transformers , two 220 kV line bays & one 220 kV Bus Coupler with Double Bus Single Breaker Scheme.
  • Developed Test protocols for testing of all switch yard Equipment Preparation of schematic and interconnection wiring diagrams of 220KV Shahi Bagh.
  • Relays Calculations and designing of teleprotection schemes with the help of NESPARK for 220KV Shahi Bagh Grid Station Peshawar.
  • Represented WAPDA in erection, testing commissioning & inspection of two 500 kV bays under taken by M/s Siemens Germany at 500 KV Grid Station Rawat and one TransformerBay.

Relay Setting Calculation:-

Setting calculations of protection relays of Generator, Transmission line and Transformer using DIGSI, CAP540,Micom S1 and SEL Accelerator Softwares. The typical example of these relays are

Distance Relays D60, SEL331,7SA511,7SA522,7SA513,7SA561,REL531,

REL521 , REL511 ,Micom(Areva) P441,P-442, LZ31,Optimho,Quadramho,L3WYS,RAZOA

L8b,LZ96a,RAZFEE etc

Differential Relays SEL 587,SPAD 346C,7UT612, 7UT512, RET 316, Micom P540,MBCH13, MBCH12 etc

O/C & E/F Relays IM30-G,MIF-II, SEL 551,CDG21, CDG61, CTU, MCGG,

7SJ602

7SJ600,SPAJ140C,Micom P-120 etc

Bus bar Relays RADHA ,MFAC 34, REB500,MicomP740

REF Protection MCAG 14, RADHD,RADHA

Breaker failure C60, MCTI, 7SV512,7SV600,Micom P-821

Over Excitation 7RW600, RALK, RATUB

Over Load UM30, MCHD 04, MCTI 39.

Over Voltage MVTD 12, UT 91

Fault Locator RANZA, DLDS 3000

Trip circuit MVAX(Study & application)

Generator Protection Micom P342, IM30-G

preparation of Interconnection and Schematic Drawings and vettting of 132kv Substations

  • Inspection of Cable Differential Panel, Capacitor relay and Control Panel and testing of relays installed in relay panels submitted by M/s Siemens.
  • Preparation of 132kV Transmission lines Schematic Drawings and interconnections for 220 kV Grid station Muzaffargarh.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay of 132kV Grid Stations submitted by NSI(ABB).
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay of 132kV AIS Grid Station Wazirabad Road Cantt submitted by M/s Siemens.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay of 132kV AIS Grid Station Punjab Industrial Estate Sunder Lahore submitted by

M/s Siemens.

  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay of 132kV AIS Grid Station Bahria Town Rawalpindi submitted by M/s Siemens.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay, AC/DC Aux supply Control Panel, 11kV Incoming, Out going and Bus Coupler Panels of 132kV AIS Grid Station Tarnol Islamabad submitted by M/s Areva.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay, AC/DC Aux supply Control Panel, 11kV Incoming, Out going and Bus Coupler Panels of 132kV AIS Grid Station Fatah Jang Islamabad submitted by M/s Areva.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay, Bus Coupler Panels of 132kV GIS Grid Station Sherawala Gate submitted by M/s PEL.
  • Inspection of 132kV Control and Relay Panels for Line and TrafoBay, AC/DC Aux supply Control Panels manufactured by M/s PEL.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay, AC/DC Aux supply Control Panel, 11kV Incoming, Out going and Bus Coupler Panels of 132kV AIS Grid Station Ghunike Sialkot submitted by M/s PEL.
  • Vetting of 132kV Control and Relay Panels for Line and TrafoBay, AC/DC Aux supply Control Panel, 11kV Incoming, Out going and Bus Coupler Panels of 132kV AIS Grid Station PAC Kamra Attock submitted by M/s PEL.
  • Study the complete Busbar Protection Scheme at Mangla Power House and recommend the remedial measures.

Thermal Power Plants Experience:

  • Vetting of relays setting for 132kV/11.5kV ,165MW Attock Gen LTD.
  • Approval of Protective relays, Protection Scheme Schematics and relays setting calculations of Orient power House.
  • Approval of Protective relays, Protection Scheme Schematics and relays setting calculations of Sapphire power House.
  • Vetting of tripping and logic Diagram and 220kV Protection and Metering Concept Diagram of Foundation Power House.
  • Approval of protection relays of Altern Energy Power House.

Consultancy, Analysis & Training Experience:-

  • Provide consultancy services to Areva regarding relay setting calculations of Transmission Line and Transformer protection, slope calculation of differential, three phase and single phase fault level calculations.
  • Deliver Training Course to ABBPakistan on ETAP 6.0 (Power System Analysis Tool) modules e.g Short Circuit Studies, Load Flow Analysis, Relay Co-ordinations, Harmonics Analysis, Transient Analysis, Transformer sizing, Ground Grid etc.
  • Provide consultancy services regarding settings and testing ofComplete Generator Protection ( Make Microelettrica Scientifica Italy relays) to Prescon Engineering company.
  • Deliver Lectures on Power system protection and Protective Relays to different Power Utilities.
  • Provide Consultancy Services for the Preparation of 132kV XLPE Under ground cables Specifications to Power Com Consultants.

Testing Experience:-

  • Low Resistance Ohm meters (DLRO), Contact resistance Measurement Test Set, Insulation resistance test set.
  • Transformer testing Equipment like C&DF/ Power Factor test set, Winding resistance, Transformer Turn Ratio, Excitation Current .
  • The latest numerical relays were tested using following test sets and software

Test Set ▪ Freja 300 ▪ Omicron CMC 156,256 ▪ F6150 (DOBLE)

Software ▪ Digsi 4.4 ▪ Freja win.

  • Stability of bus bar differential, transformer differential and restricted earth fault relays through primary injection.
  • Testing and commissioning of 132kv Circuit breakers,220v Rectifiers and 160MVA Auto Transformer 220/132kv with the help of HYUNDAI Engineers.
  • Testing of 220kVGAS INSULATED SYSTEM.

Special Professional Experience & Trainings:

  • Attended the APPS (Analysis of Protection and Power System) Course in Stafford UK for five weeks.
  • Induction Training course
  • Basic management Training course.
  • Programming & control of PLCs (Programmable Logic Controller)
  • Remote Substation monitoring on TCP/IP Network.
  • Two Days Training on Areva (Alsthom) Protection Relays.
  • Training course offered by Siemens Germany on Micro-controller based Distance Relays, Auto Recloser and syn check and distance protection monitoring functions.
  • Attended seminar on Substation Automation offered by M/s ABB.
  • Attended seminar on Introduction and advantages of Polymer Surge Arrestors offered by M/s Siemens.
  • Attended seminar on Transformer Protections at various substations offered by M/s Siemens.
  • Attended the two days Training Seminar on Differential relays and substation automation System offered by Siemens.

Computer Skills:

Skill NameSkill Level Last Used Yrs Exp.

  • DIGSI 4.8 Expert 2009 6 Year
  • CAP540 Expert 2009 5 Year
  • Micom S1 Expert 2009 5 Year
  • Linux/ Windows 98/2000/XP Expert 2008 7 Years
  • ETAP 6 Expert 2009 2 Year
  • Microcontroller Expert 2006 3 Year
  • Auto Cad Intermediate 2006 1 Year
  • ETAB Intermediate 2006 1 Year
  • Matlab Intermediate 2003 3 Year
  • Computer Interfacing Intermediate 2001 2 Years

Professional Memberships:

  • Pakistan Engineering Council
  • Member of “The Institute of Electrical and Electronics Engineers”
    (IEEE)

Reference:

To be provided on demand.