/ CFAS Enterprises Inc.
After Market Utility Power Equipment Brokerage
Mailto:
Turbine URL: http://CFASPower.com/Index.html
Reciprocating URL: http://CFASPower.com/Recips.html
GTG_1295JL_Alison50Hz.doc

1 Rebuilt HITACHI 6360KW 50Hz CTG With Allison Engine 501-KH5 2000 Model

1.  Maker: Allison Gas Turbine generator

2.  Rating: 6350kw/501-KH05 Type co-generator

3.  Frequency: 50Hz

4.  Voltage: 3300

5.  Generators Toshiba Takl-Kg

6.  Hour Meter: 56,762hrs

7.  G/T starting number: 130 times

8.  Last Overhaul time: April, 2008

9.  After Overhaul time

10.  Fuel: Natural Gas

11.  Fuel consumption: 0.27kw/m3

12.  Speed: 14,586 RPM

13.  Stopped operation: July, 2008

14.  Location: Japan

Asking Price USD $ 385,000 FOB Site Dismantled & Put To Customer's Container

Availability : Immediate

Scope of quotation

our company's scope of quotation is as below

A. (1)gas turbine power plant equipment
(1-1)
Gas Turbine
/ Maker/Model No / Alison 501-Kh05 /
set
Type / Single Open Cycle 1 Shaft Type
Structure / Compressor Arial Flow 14 Step
Burner
Turbine Arial 4 Step
Natural Gas
Rated Rpm / 14586 Rpm
Rotation Direction / CCW Seen From Exhaust Side
Starting Device / Electric Driven
Governor / TCSD Type Digital Type
(1-2)
Reduction Gear
/ Type / Parallel Shaft 1 Step Gear Type /
1Set
Lubrication Type / Forced Lubrication
Shaft Qty / 2 Shafts/In Sliding Bearing
Reduction Rate / 9.724(14586/1500rpm)
Coupling / Flexible Dia Flame Type
(1-3)
Generator
/ Type / Transverse Axial Rotation Field Magnet /
1Set
Three Auternationg Current Synchero-Nous Generator
Cooling Type / Self Ventilation
Rated Output / 6350 Kw
Rated Capacity / 7056 Kva (@0℃)
Power Factor / 90%
Voltage / 3300V
Insulation / F Type
Rpm / 1500Rpm
Frequency / 50Hz
(1-4)
Lubrication Equipment / Line Up Machinery
Main L.O Pump / Reduction Gear-Directly Coupled Gear Pump / 1 Set
Auxiliary L.O Pump / Electric Driven Gear Pump / 1 Set
L.O Cooler / Plate Pump / 1 Set
L.O Filter / Double Type / 1 Set
L.O Tank / Steel Plate Welded Type / 1 Set

(1) gas turbine generate equipment(continuous)

(1-5)
Starting Motor Equipment
/ Starting Motor Type /
Wound Rotor 3phase Alternating Current Induction Motor
Rated / 250kw(Ac400v Applied)
Auxiliary / Brush Lifting Device
Starting Type / Resistance Starting Way
(1-6)
Enclosure And Auxiliaries
/ Type / Section Snap Steel Aieload
Gas Detector / Contacted Firing
Heat Detector / Fixed Temp Spot Type
(1-7)
Intake And Exhaust
Equipment For Gas Turbine
/ Intake Filter Type / 3 Step(Hepa) Filter
Cut Type
Steel Plate Welded Type
Intake Silencer / Split Type
Exhaust Silencer / Combined Type
(1-8)
Ventilation Equipment
(Enclosure Each Room) / Line Up Machines
Turbine Room Inlet Silencer
/ Split Type
Turbine Room Outlet Silencer / Split Type
Generator Room Inlet Silencer / Split Type
Generator Room Outlet Silencer / Split Type
Turbine Room Ventilation Fan / Axial Flow(Idf Type)
Generator Room Ventilation Fan / Axial Flow(Idf Type)
(1-9)
Others / Ventilation Duct / Steel Plate Welded Type
Expansion Factor / Campus Type
Ladder / Steel Plate Welded Type
Distance Stair