SYSTEMPAC DESIGN guide
IBM Global Technology Services
Updated: 11/14/2018
Table of Contents
Preface
Contacts
Instructions
Instructions for SystemPac Manufacturing
Initial Enrichment Data
Customer Contact Information
IBM Contact Information
Tape Media Selection
CPU Information
System Name and Global CSI Selection
Standalone Utility Tape
JES Subsystem
Selective Follow-On Service
Zone Nicknames/Zone Names
Terminal and Printer Information
I/O Configuration Information
Volume Layout
Additional build Instructions
UNIX File System
Indirect Catalog Option
SMPE Data sets
Master Catalog Options
Data set Names & User Catalog Options
Catalogs Volume Assignement
Static System Symbols
Preface
This format of the enrichment formis unique to the IBM Rapid Deployment of z/OS and DB2 offering, and is used to collect customization data to tailor build your SystemPac. Upon completion of this form, please email itback to IBM Manufacturing at . If there are questions with this form, please raise them to the IBM personnel who sent this form to you.
Summary of changes:
Date / Change03/06/2007 / Original copy
04/05/2007 / Updated Parallel Sysplex offerings
06/18/2007 / Modified enrichment form to meet IBM Rapid Deployment of z/OS and DB2 requirements
19/03/2008 / Added Catalogs Volume assignment
26/09/2008 / Added JES Subsystem selection
09/02/2010 / Removed ISV customization questions
Contacts
Contact / UserIdIBM Manufacturing /
Instructions
NOTE: Please read these instructions carefully before filling out your portion of this enrichment form.
When filling out this enrichment form, onlyfieldsthatare designated with a red asterisk and are highlighted in yellowrequire your input. All other fields are predefined default valuesfor this offering and may notbe changed. To clarify, you are only to provide input into the fields of tables listed in the following section marked “User input required.”
User input required
For your reference, the following are links to the tables and pages that require your input. To link to that section of the document, enter CTRL + click with first mouse button. Once you input the required data, use the Return to Instructionslink in the document to return to these instructions.
CustomerContact Information (see page5)
IBM ContactInformation (see page5)
Tape Media Selection(see page5)
CPU Information (see page6)
JES Subsystem selection (see page 7)
Selective Follow-On Service (see page 7)
Instructions for SystemPac Manufacturing
NOTE: Please read additional build instructions required.
For your reference, the following are linksto additional instructions or notes that are unique to this IBM Rapid Deployment of z/OS and DB2 offeringorder. To link to that section of the document, enter CTRL + click with first mouse button.
Changes for Zone Nicknames/Zone Names(see page8)
Terminal and Printer Information(see page9)
I/O configuration information(see page9)
Additionsto DASD and volume layout(see page10)
Additional build Instructions (see page 11)
Additions to SMP/E data sets(see page12)
Data set Names & User Catalog Options(see page16)
NOTE: Please note the unique default values that have been added for theIBM Rapid Deployment of z/OS and DB2 Offering.
Throughout this document, the additional unique default values are designatedwith the following: “Defaults Unique to This Offering.”
Initial Enrichment Data
Please fill out the appropriate fields, throughout the following Enrichment Form, according to the instructions on page 4. Once the form has been received, IBM will input the information into our Production System. IBM will then begin the build of your SystemPac.
Customer Contact Information
Table 1 Customer Contact Information
Customer Name / *Customer Number / *
Customer Contact / *
Phone Number
Phone Number / *
Email / *
Customer Mailing Address for SystemPac / *
Return to Instructions
IBM Contact Information
Table 2 IBM Contact Information
Name / *Phone Number / *
Email / *
TECH-LINE
(if known)
Returnto Instructions
Tape Media Selection
Table 3 Media Selection
Please select a media type for your SystemPac order.
Select Media Type / Notes3590 - High Density 138 Tracks
3592 – High Density 512 Tracks
Return toInstructions
CPU Information
Table 4 CPU Information
Enter CPU InfoCPU TYPE / *
CPU Model / *
CPU Serial / *
CPU Indicator
Return to Instructions
System Name and Global CSI Selection
Table 5 System Name and Global CSI Selection
Enter Info / NotesSYSNAME / PRA1 / Default is PRA1
Multiple GLOBAL CSI? (Yes or No) / No / Entering 'Yes' to 'Multiple GLOBAL CSI' will allow the Global CSI datasets to spread over each SREL (i.e. CICS,DB2,IMS or NCP) on an order, otherwise only ONE Global CSI dataset will be assigned.
Standalone Utility Tape
Table 6 Standalone Utility Tape
Enter Info / NotesStandalone Utility Tape Required / Yes / Yesis required because the ‘Standalone Utility Tape Required’ will include 2 Standalone tapes on the same delivery media type:
- Standalone Dump/Restore tape using DFSMSdss
- Standalone DASD Initialization tape using ICKDSF
Note: this option is only applicable to tape media delivery
JES Subsystem
Table 7JES Subsystem
Enter INFO / NotesJES subsystem:
JES2 or
JES3 or
Both / Select JES Subsystem that you would like to be delivered in SystemPac order.
Default is both JES2 and JES3.
Note: This option is valid with SystemPac z/OS V1R10 and up. The orders with SystemPac z/OS V1R9 do not support this option.
- If JES2 is specified, the JES3 Subsystem will not be delivered in the SystemPac
- If JES3 is specified, the JES2 Subsystem will not be delivered in the SystemPac
- If BOTH is specified, both JES2 and JES3 will be delivered in the SystemPac
Selective Follow-On Service
The Selective Follow-On Service (SFS) package includes HOLDDATA, HIPER PTFs,and PTFs correcting PTFs-in-error with all required “PRE” REQ service.
The package includes installation JCL and customized documentation for all subsystems in the original order. SFS tape media and shipping method will remain the same.
You can request up to 3 SFSs per SystemPac. We recommend that the SFS(s) are set to be shipped at 30 day intervals.
Table 8 Service
EnterSelection / NotesNumber of SFSs / 3 / (0,1,2,or 3), default is 3.
Frequency / 30 / Number of days between SFS Packages (Maximum 120 Days), default is 30.
Electronic Delivery (via FTP) / Yes / (Yes or No)
e-mail for Electronic Delivery / * / Required if Electronic Delivery is specified to Yes
Return toInstructions
Zone Nicknames/Zone Names
Zone checking will be performed to ensure proper grouping/product compatibility and that products of different SRELs are not in the same zone.Default zone names have been provided; however, you have the option of selecting your own zone names.
Zone names MUST be less than or equal to 7 characters in length and each zone name MUST be unique.
If you have other products which are not listed in Table 8and you want to assign specific zones to them, please add them to the table below or request a list of your ordered products.
Table 9SMPE ZONEInformation
Predefined values fromSoftware Manufacturing / Defaults Unique to This Offering
Zone
Description / Target
Zone
Name / DLIB
Zone
Name / Change to
Target Zone
Nameif Required / Change to
DLIB Zone
Nameif Required
z/OS Base / MVST100 / MVSD100 / TZOS1AA / DZOS1AA
JES2 / MVST110 / MVSD110 / TZOS1AA / DZOS1AA
JES3 / MVST111 / MVSD111
SDSF / MVST112 / MVSD112
DB2 / DB2T300 / DB2D300 / TDB291A / DDB291A
SystemPac Full Volume Dump format only
Add products below that you want to have assigned specific SMP/E zone.
(The products should not have dependencies on z/OS Base product)
Product Number and version / New Target Zone Name / New DLIB Zone Name
DBDDB2 Tools / TDB2TUL / DDB2TUL
Note: In order to provide additional migration flexibility, three additional SMP/E zones are defined with z/OS R11, JES2 with SDSF support is placed in one zone, JES3 in another and SDSF in third zone, all are separated from the remainder of z/OS. With SystemPac Full Volume Dump format you have option to merge JES2, SDSF product or JES3 into z/OS base zone, specifying the z/OS base zone names (ex. MVST100/MVSD100). If you specified that you would like that JES3 or JES2 not to be delivered in SystemPac order then, product code and related SMP/E zones for JES2 or JES3 will not be assigned and delivered with your order.
In SystemPac Copy By Data set format, the new zones can later be merged into the z/OS zone during installation or at a later time, depending on the customer migration preference.
If you ordered WebSphere for z/OS product, as default it would be delivered in a separate SMP/E zone.
.
Terminal and Printer Information
Master Consoles
Table 10 Master Consoles
Address / Type / Model / NotesMVS Master Console / 060 / 3279 / 3 / The address specified for the master console must be in the Nucleus Initialization Program (NIP)statement of your MVSCP or identified as a NIP console in the IODF.
Valid values for MVS Master and JES3 Console are: 3270,3277, 3278 OR 3279
Alternative Console
TSO Terminals
Table 11 Local TSO Terminals
Address / Type / Model / NotesTSO TERM1 / 062 / 3279 / 3 / A minimum of 2 terminal addresses are required, however up to six addresses may be included.
TSO TERM2 / 063 / 3279 / 3
TSO TERM3 / 064 / 3279 / 3
TSO TERM4 / 065 / 3279 / 3
TSO TERM5 / 066 / 3279 / 3
TSO TERM6
I/O Configuration Information
Table 12 IODF
IODF Input / RDT.IODF00.CLUSTERConfiguration EDT / 00
Configuration ID / PRDCNAO
DASD
Please provide 3 SYSRES, 3 DLIB, 1 CATALOG and 1 SMP/E. If the order
has many products, more volumes may be needed.Place third party (vendor) products on different packs, separate from IBM products, place subsystem on its own different pack(s). Enter Required Volume Information:
Minimum DASD requirement
2 SYSRES volumes
2 DLIB volumes
1 Catalog volume
1 SMP/Evolume
Table 13Volume Information
Volume Type / VolserName (6 char, alphanum) / Address
(4 digits in hex) / Unit Type
(3390) / Model
SYSRES VOLUME #1 / SYSRSA / 1000 / 3390 / 9
#2 / SYSRSB / 1001 / 3390 / 9
#3
DLIB VOLUME #1 / DLIB8A / 1002 / 3390 / 9
#2 / DLIB8B / 1003 / 3390 / 9
#3
CATALOG VLUME / DMCAT / 1004 / 3390 / 9
SMP/E VOLUME #1 / SMPVOL / 1005 / 3390 / 9
#2
Volume Layout
Table 14Volume Layout for DB2 Products
Type / Volser / Address / Unit / ModelDB2 TARGET / DSDBLA / 1006 / 3390 / 9
DB2 DLIB / DSDBLA / 1006 / 3390 / 9
DB2 SMP / SMPVOL / 1005 / 3390 / 9
DB2 Tools / DSPROD / 1007 / 3390 / 9
NOTE: If an installation has limited volume space and there are not a lot of products ordered, 2 SYSRES and 2 DLIBs may be enough to hold the content. Under such circumstances, contact CustomPac Support Group () about the situation. If during manufacturing, the specified number of volumes is not enough to hold the content, I/T specialist will be informed to obtain more volumes from the customer. Only resolve to use this if number of volumes is a critical factor in an installation. Remember that in so doing, this may cause a delay in manufacturing.
Additional build Instructions
NOTE: The following are additional build instructions for SystemPac Software Manufacturing.
1)Place the z/OS target CSI and SMPLTS, SMPMTS, SMPSCDS, SMPSTS data sets on the SYSRES volume
2)Place the z/OS DLIBCSI on the DLIB volume
3)On SMPVOL include the global CSI, SMPPTS and SMP related log data sets
4)The base DB2 SMP related data should go on DSDBLA volume
5)The DB2 tools SMP related data sets should go on DSPROD volume
6)Include the IODF on the catalog volume
7)Do NOT define OPERCNSL for standalone DFSMSdss utility
UNIX File System
Table 15 HFS or zFS
SMS Options / HFS or zFS / NotesBuild file system in zFS or HFS format? / zFS / Default is zFS
Indirect Catalog Option
NOTE:If indirect catalog referencing is not required (No is chosen) then No must be also entered for static system symbols.
Indirect cataloging allows the system to dynamically resolve volume anddevice typeinformation for non-VSAM data sets residing on the systemresidence volume (SYSRES) when accessed through the catalog. This allowsyou to change the volume serial number or device type of the systemresidence volume without also having to recatalog the non-VSAM data sets onthat volume. Indirect cataloging can be used only for non-VSAM data setswhich reside on the SYSRES.
With z/OS, in which many elements and optional features are provided, the space required by the data sets which logically belong on SYSRES may exceed the capacity of a single DASD volume. If some of these data sets are placed on overflow volumes rather than SYSRES, there is no way in the current indirect cataloging support to refer to them indirectly.
Table 16 Indirect Catalog Option
Catalog Options / Yes or NoDoes this order required Indirect Catalog Referencing? / Yes
SMPE Datasets
SMPE VSAM Datasets
Define Zone CSI Names: changes to CSInames if required.
- Restrictions:
- Names must be less than or equal to 26 characters
- You have the option of grouping 2 entries in the same zone byspecifying the same zone name, or else the names must be uniquefor different zones.
- Two different COBOLs can't live in the same zone.
- Subsystems and their related products must live in the same zone
(For example,GDDM for CICS has to be in the same zone as CICS itself)
Table 17Single SMPE Global
For Single GlobalCSI Names / Predefined values from Software Manufacturing / Defaults Unique to This OfferingDefault ZoneCSI Name / Change ToZone CSI Name if Required
MVS GLOBAL CSI: / SMPE.GLOBAL.CSI / SMPE.GLOBAL.CSI
TARGET MVS / SMPE.MVS.TARGET.CSI / TZOS1AA.TARGET.CSI
DLIB MVS / SMPE.MVS.DLIB.CSI / DZOS1AA.DLIB.CSI
TARGET DB2 / SMPE.DB2.TARGET.CSI / TDB291A.TARGET.CSI
DLIB DB2 / SMPE.DB2.DLIB.CSI / DDB291A.DLIB.CSI
TARGET DB2 Tools / TDB2TUL.TARGET.CSI
DLIB DB2 Tools / DDB2TUL.DLIB.CSI
SMPE TARGET & DLIB Non-VSAM Datasets
NOTE: To software manufacturing, see changed zone names in table below.
Table 18 SMPE Target & DLIB Non-VSAM
PredefinedValues from
Software
Manufacturing / Defaults Unique to This
Offering / Predefined Values
from Software
Manufacturing / Defaults Unique to This Offering
ZONE SREL/ Zone Name
/ Change to ZONE SREL/Zone Name / SMPE
DDDEF
DDNAME / Data Set Name / Change to Data Set Name if Required / Zone Type
MVS / MVS
GLOBAL / SMPGLOG / SMPE.SMPGLOG / SMPE.SMPGLOG / GLOBAL
SMPGLOGA / SMPE.SMPGLOGA / SMPE.SMPGLOGA / GLOBAL
SMPPTS / SMPE.SMPPTS / SMPE.SMPPTS / GLOBAL
DB2D300 / DDB291A / SMPDLOG / SMPE.DB2D300.SMPDLOG / SMPE.DB291A.SMPDLOG / DLIB
SMPDLOGA / SMPE.DB2D300.SMPDLOGA / SMPE.DB291A.SMPDLOGA / DLIB
DB2T300 / TDB291A / SMPLTS / SMPE.DB2T300.SMPLTS / SMPE.DB291A.SMPLTS / TARGET
SMPMTS / SMPE.DB2T300.SMPMTS / SMPE.DB291A.SMPMTS / TARGET
SMPSCDS / SMPE.DB2T300.SMPSCDS / SMPE.DB291A.SMPSCDS / TARGET
SMPSTS / SMPE.DB2T300.SMPSTS / SMPE.DB291A.SMPSTS / TARGET
SMPTLOG / SMPE.DB2T300.SMPTLOG / SMPE.DB291A.SMPTLOG / TARGET
SMPTLOGA / SMPE.DB2T300.SMPTLOGA / SMPE.DB291A.SMPTLOGA / TARGET
MVSD100
(MVS) / DZOS1AA / SMPDLOG / SMPE.MVSD100.SMPDLOG / SMPE.ZOS1AA.SMPDLOG / DLIB
SMPDLOGA / SMPE.MVSD100.SMPDLOGA / SMPE.ZOS1AA.SMPDLOGA / DLIB
MVSD110
(JES2) / DZOS1AA / SMPDLOG / SMPE.MVSD110.SMPDLOG / SMPE.ZOS1AA.SMPDLOG / DLIB
SMPDLOGA / SMPE.MVSD110.SMPDLOGA / SMPE.ZOS1AA.SMPDLOGA / DLIB
MVSD111
(JES3) / SMPDLOG / SMPE.MVSD111.SMPDLOG / DLIB
SMPDLOGA / SMPE.MVSD111.SMPDLOGA / DLIB
MVSD112
(SDSF) / SMPDLOG / SMPE.MVSD112.SMPDLOG / DLIB
SMPDLOGA / SMPE.MVSD112.SMPDLOGA / DLIB
MVST100 / TZOS1AA / SMPLTS / SMPE.MVST100.SMPLTS / SMPE.ZOS1AA.SMPLTS / TARGET
SMPMTS / SMPE.MVST100.SMPMTS / SMPE.ZOS1AA.SMPMTS / TARGET
SMPSCDS / SMPE.MVST100.SMPSCDS / SMPE.ZOS1AA.SMPSCDS / TARGET
SMPSTS / SMPE.MVST100.SMPSTS / SMPE.ZOS1AA.SMPSTS / TARGET
SMPTLOG / SMPE.MVST100.SMPTLOG / SMPE.ZOS1AA.SMPTLOG / TARGET
SMPTLOGA / SMPE.MVST100.SMPTLOGA / SMPE.ZOS1AA.SMPTLOGA / TARGET
MVST110
(JES2) / TZOS1AA / SMPLTS / SMPE.MVST110.SMPLTS / SMPE.ZOS1AA.SMPLTS / TARGET
SMPMTS / SMPE.MVST110.SMPMTS / SMPE.ZOS1AA.SMPMTS / TARGET
SMPSCDS / SMPE.MVST110.SMPSCDS / SMPE.ZOS1AA.SMPSCDS / TARGET
SMPSTS / SMPE.MVST110.SMPSTS / SMPE.ZOS1AA.SMPSTS / TARGET
SMPTLOG / SMPE.MVST110.SMPTLOG / SMPE.ZOS1AA.SMPTLOG / TARGET
SMPTLOGA / SMPE.MVST110.SMPLOGA / SMPE.ZOS1AA.SMPTLOGA / TARGET
MVST111
(JES3) / SMPLTS / SMPE.MVST111.SMPLTS / TARGET
SMPMTS / SMPE.MVST111.SMPMTS / TARGET
SMPSCDS / SMPE.MVST111.SMPSCDS / TARGET
SMPSTS / SMPE.MVST111.SMPSTS / TARGET
SMPTLOG / SMPE.MVST111.SMPTLOG / TARGET
SMPTLOGA / SMPE.MVST111.SMPLOGA / TARGET
MVST112
(SDSF) / TZOS1AA / SMPLTS / SMPE.MVST111.SMPLTS / SMPE.ZOS1AA.SMPLTS / TARGET
SMPMTS / SMPE.MVST112.SMPMTS / SMPE.ZOS1AA.SMPMTS / TARGET
SMPSCDS / SMPE.MVST112.SMPSCDS / SMPE.ZOS1AA.SMPSCDS / TARGET
SMPSTS / SMPE.MVST112.SMPSTS / SMPE.ZOS1AA.SMPSTS / TARGET
SMPTLOG / SMPE.MVST112.SMPTLOG / SMPE.ZOS1AA.SMPTLOG / TARGET
SMPTLOGA / SMPE.MVST112.SMPLOGA / SMPE.ZOS1AA.SMPTLOGA / TARGET
DDB2TUL / SMPDLOG / SMPE.DB2TUL.SMPDLOG / DLIB
SMPDLOGA / SMPE.DB2TUL.SMPDLOGA / DLIB
TDB2TUL / SMPLTS / SMPE.DB2TUL.SMPLTS / TARGET
SMPMTS / SMPE.DB2TUL.SMPMTS / TARGET
SMPSCDS / SMPE.DB2TUL.SMPSCDS / TARGET
SMPSTS / SMPE.DB2TUL.SMPSTS / TARGET
SMPTLOG / SMPE.DB2TUL.SMPTLOG / TARGET
SMPTLOGA / SMPE.DB2TUL.SMPTLOGA / TARGET
Master Catalog Options
Table 19 Master Catalog Options
Master Catalog / DefaultsUnique to This OfferingMaster Catalog Name / MASTER.DRIVING.CATALOG
Dataset Names & User Catalog Options
You have the option to change the product high level qualifier and catalog them into the user catalog. Please specify below which alias you want to rename, and where the alias should be cataloged in.
Important Notice: The list below is a GENERIC list ONLY. All product DSNames are not included and it is not necessary to specify changes on all the Aliases listed. If you have other Aliases that are not listed below and you need them changed, please add them to this list.
Table 20Dataset & User Catalogs
PredefinedValues from
Software
Manufacturing / Defaults Unique to This Offering
ALIAS / ALIAS
(User defined) / Target System Catalog
(Default is Master Catalog or
Specify User Catalog) / Catalog Volume
(Additions to
This Offering)
ANF
AOP
ASM
CBC
CDS
CEE
CMX
CPAC / MUST BE IN MASTER CATALOG / DMCAT
CSF
DSN910 / DB2910.SETA / USERCAT.DSDBLA.DB2910 / DSDBLA
ADB / USERCAT.DSPROD.DB2TOOLS / DSPROD
ANL / USERCAT.DSPROD.DB2TOOLS / DSPROD
ARY / USERCAT.DSPROD.DB2TOOLS / DSPROD
CKZ / USERCAT.DSPROD.DB2TOOLS / DSPROD
DAH / USERCAT.DSPROD.DB2TOOLS / DSPROD
DDA / USERCAT.DSPROD.DB2TOOLS / DSPROD
EGF / USERCAT.DSPROD.DB2TOOLS / DSPROD
FEC / USERCAT.DSPROD.DB2TOOLS / DSPROD
GOC / USERCAT.DSPROD.DB2TOOLS / DSPROD
HAA / USERCAT.DSPROD.DB2TOOLS / DSPROD
TZOS1AA / USERCAT.SYSRSA / SYSRSA
DZOS1AA / USERCAT.DLIB8A / DLIB8A
TDB291A / USERCAT.DSDBLA.DB2910 / DSDBLA
DDB291A / USERCAT.DSDBLA.DB2910 / DSDBLA
TDB2TOOL / USERCAT.DSPROD.DB2TOOLS / DSPROD
DDB2TOOL / USERCAT.DSPROD.DB2TOOLS / DSPROD
EOY
EPH
EUV
FFST
GDDM
GIM
GLD
GSK
HCM
ICA
ICF
ICQ
IMW
IOA
IOE
ISF
ISP
NETVIEW
OMVS / OMVSD / USERCAT.DMCAT / DMCAT
REXX
SCRIPT
SMPE
SYS1 / MUST BE IN MASTER CATALOG
TCPIP
TIVOLI
Catalogs Volume Assignement