Revision 1Date Issued: 26th October 2005
1. Identification of the substance/preparation and companyProduct Name:Peran MDP
Application: Membrane curing and dust binding of concrete.
Manufacturer:
Flowcrete UK Ltd., The Flooring Technology Centre, Booth Lane, Moston, Sandbach, Cheshire. CW11 3QF
Tel: +44 (0)1270 753000Fax: +44 (0)1270 753333
E-mail: Website:
2. Composition/information on constituentsIngredients are not classified as hazardous. Contains an acrylate copolymer at 10 – 20%.
3. Hazards Identification
Repeated and/or prolonged contact with skin and eyes may cause some irritation.
4. First Aid measuresInhalation / : / Not applicable.
Skin contact / : / Remove contaminated clothing and wash with soap and plenty of water.
Seek medical attention if any symptoms persist.
Eye Contact / : / Hold eyelids apart and flush with plenty of water.
If irritation persists, seek medical advice.
Ingestion / : / Wash out mouth, nose and throat with water. Give plenty of water to drink. Seek medical advice.
Do not induce vomiting unless under medical supervision.
5. Fire-fighting measures
Suitable extinguishing media / : / Water spray, foam, powder or carbon dioxide.
Un-Suitable extinguishing media / : / Water in jet.
Special exposure hazards / : / Toxic fumes emitted in a fire – carbon monoxide and carbon dioxide (CO + CO2).
6. Accidental release measures
Personal precautions / : / Use personal protective equipment as detailed in Section 8.
Ensure adequate ventilation. Avoid repeated skin contact.
Environmental precautions / : / Prevent the product from entering sewers and waterways.
Methods for cleaning up / : / Absorb on inert absorbent material (e.g. sand) and collect in suitable containers for disposal in accordance with Section 13.
7. Handling and storage
Handling / : / Ensure adequate ventilation. Use personal protective equipment as detailed in Section 8.
Handle and open package with care. No eating or drinking in the workplace.
Storage / : / Store in a dry, cool, well-ventilated place, away from direct sunlight.
Store at a temperature of 5 – 40 oC.
Protect from frost.
8. Exposure controls/personal protection
There are no ingredients with Workplace Exposure Limits (WELs)
Engineering measures to reduce exposure / : / Adequate ventilation.
Personal protective equipment / :
Respiratory protection / : / Not required in well ventilated areas.
Eye protection / : / Goggles or face shield.
Hand protection / : / Waterproof gloves.
Skin and body protection / : / Protective suit.
Protective measures / : / Use of the basic principles of Industrial Hygiene will enable this material to be used safely.
9. Physical and chemical properties
Appearance / : / white liquid / pH / : / 7.5 – 8.5
Odour / : / None / Relative Density / : / ~1
Boiling Point / : / ~100 oC / Water solubility / : / Fully miscible
Flashpoint / : / > 100°C / Explosion limits / : / Not applicable
10. Stability and reactivity
Material isstable under the recommended storage conditions.
Conditions to avoid / : / Protect from frost.Materials to avoid / : / None known to us.
Hazardous decomposition products / : / None known , except in a fire – see section 5.
11. Toxicological information
Long-term experience of this product type indicates no danger to health when properly handled under industrial conditions.
Prolonged or repeated skin contact may be irritating to some individuals and may cause some dryness of the skin.
Eye contact may cause some redness and sting.
12. Ecological informationThe product is miscible with water, and as such could cover considerable distances if spilled into waterways.
It is not considered to be harmful to aquatic organisms.
13. Disposal considerationsUnused Product/waste from cleaning etc. / : / Dispose of in accordance with local and national regulations.
Do not empty into drains, sewers or water courses.
EC Waste Catalogue (EWC) code: 08 01 20
[Waste products from the Manufacture, Formulation, Supply and Use (MFSU) of paint and varnish. Aqueous suspensions containing paint or varnish other than those mentioned in 08 01 19.]
Contaminated packaging / : / Uncleaned, treat as for unused product.
After cleaning, empty containers can be landfilled in accordance with local regulations.
14. Transport information
Not classified as hazardous for transport.
15. Regulatory informationClassification according to EEC directive: NoneHazard Symbols:None
R-phrases / : / NoneS-phrases
S36/37/39 / : / Wear suitable protective clothing, gloves and eye/face protection.
Special provisions statement / : / None.
Hazardous component(s) which must be listed on the label / : / None.
EC Directives: / Dangerous Substances Directive, 67/548/EEC & adaptations.
Dangerous Preparations Directive, 1999/45/EC.
Safety Data Sheets Directive, 91/155/EEC and adaptations.
Statutory Instruments: / Chemicals (Hazard Information & Packaging for Supply) Regs 2002.
Control of Substances Hazardous to Health Regs 2002.
Environmental Protection (Duty of Care) Regs. 1991.
Codes of Practice / Waste Management. The Duty of Care.
Approved classification and labelling guide (Fifth edition). L131.
The compilation of safety data sheets (Third edition).
Guidance Notes / Occupational Exposure Limits EH40
CHIP for Everyone HSG(108)
16. Other Information
This safety data sheet has been prepared in accordance with CHIP3. The provision of Safety data sheets comes under Regulation 6 of CHIP (CHIP is the recognised abbreviation for the Chemicals, Hazard Information and Packaging Regulations). This is in addition to the Health and Safety at Work Act 1974.
Users of our products should take appropriate measures to ensure working practices are in accordance with the Control of Substances Hazardous to Health Regulations (COSHH).
This data sheet does not replace the obligation of the user to provide their own assessment of workplace risk as required by other Health & Safety legislation.
Restrictions on Use
The product is intended for use by appropriately trained applicators.
Training Advice
Applicators need to be trained in:-
The proper use of the application equipment in accordance with the technical data sheet and/or separate application instructions.
Handling and hygiene associated with use of industrial chemicals.
Correct cleaning and disposal methods.
Notes
This safety data sheet is based on our present knowledge and experience and is intended to serve as a guide for safe handling of the product regarding to health and environmental aspects.
Peran MDP Date printed 25 September, 2008 Page 1 of 5 Ref: CHIP300566