DT/ Feeder Meter MCO

Scenario 5: Only CT/PT replacement

Necessary tasks before performingCT/PT replacement:

a)Object type on device to be replaced i.e. On meter Object type should be either “DTM”, “FDRM” or ”RINM” depending on type of meter being replaced and “CT”, “PT” or “CTPT” depending on the type of transformer being replaced.

b)Authorization group should maintained on the Meter

c)Perform a Goods Receipt through MIGO transaction for new Meter and CT/PT device for the storage location of the respective Authorization group maintained on the device.

d)Class should be attached on meter in Class overview on both Old and New CT-PT.

Now Proceed with CT/PT replacementwith new T-code ZDTMETER.

Step 1: Open T-code ZDTMETER.

Step 2: Now select check box “Replace DT/ Feeder meter”. Below optionsis displayed after selectingthe check box.

Step 3: Now select check box “Replace CT/PT” and click “SUBMIT” button.

Step 4: Now enter all parameters in the next screen displayed.

Step 5: After entering all fields click “SUBMIT” button.

Note: Enter “Date” in date format as highlighted below.

Step 6: In the pop-up “Create Device replacement order” displayed on screen click “OK”.


Step 7: Now issue CT/PT against the order created in previous step. Click on check box “ITEM OK” & Click on find button as highlighted below

Step 8: Click on execute button as highlighted below.

Now select new serial number of meter to be replaced. And click button as highlighted below.

Step 9: Now click “Post” button. Material document is posted.

Step 10: Next click green “Back” button as highlighted below.

Step 11: Pop-up is displayed “Proceed with removal of meter”. Click OK.

Step 12: In next screen enter “meter readings” of meter being removed and “Activity reason”.

Click on save button as highlighted below.

Select Meter note of removed meter.


Step 13: Pop-up “Proceed with removal of CT/PT is displayed”. Click OK.

Step 14: In next screen remove CT/PT device. Select “Activity reason” and click save button.

Step 15: Pop-up “Proceed with installation of CT/PT is displayed”. Click OK

Step 16: Now enter activity reason for installation of new CT/PT. And then click save button as highlighted below.

Step 17: Pop-up “Proceed with re-installation of meter” is displayed. Click OK.

Step 18: In next screen enter “meter readings , periodic cons, No. of days , Rate type , Fact Group” of meter being re-installed and “click on save”.

Select Meter note for re-installed meter.

Step 19: Pop-up “Proceed to Technical Completion of Device Replacement Order”. Click OK

Step 20: Pop-up “CT-PT Replacement is Complete”. Click OK