______
3400Tectura Designs Precast Concrete
PART 1 - GENERAL
1.1SUMMARY
- Perform all work required to furnish and complete the proper installation ofprecast concrete.
- Types of Precast Concrete work include:
- Precast Concrete Stairs
- Precast Concrete Caps
- Precast Concrete Benches
- Precast Concrete Copings
- Precast Concrete Veneer
- Precast Concrete Planters
- Precast Concrete ______
- Setting material, grouts, sealants and caulks
- Installation of precast concrete
- Related work not specified under this section
- Installation of steel units to receive precast concrete
- Installation of Concrete substrate to receive precast concrete
1.2REFERENCES
- American Society for Testing and Materials (ASTM)
- ASTM C-150ASTM C-260ASTM C-494
ASTM C-128ASTM C-31
- Precast Concrete Institute (PCI)
1.3SUBMITTALS
- Shop Drawings
- Submit fabrication drawings of all precast concrete items showing detailed sections and profile
for all precast items. Details shall show all reinforcing and cast in hardware.
- Samples
- Submit 1 sample for color and texture approval.
- Color to be selected from manufacturersstandard offerings.
- Match existing or architect’s sample
- Custom Sample Number ______
- Submit a copy of manufacturers Quality Assurance and Procedure Manual
- Performance Requirements
- Compressive Strength 5,000p.s.i. minimum
- Air Content 6-8%
- Water-Cement Ratio .45
- Test Results
- Manufacturer shall furnish test results attesting that materials meet specification requirements.
1.4QUALITY ASSURANCE
- Comply with PCI Standards.
- Precast manufacturing plant shall be certified, category AT – Architectural Trim, at the time of bidding.
- Qualifications: Precast Concrete Manufacturer and Trade Contractor must have a minimum of 5years of successful experience on projects of similar magnitude and complexity to the indicated project.
- Manufacturer and contractor to be prequalified by Architect prior to bidding and failure todo so will void bid.
1.5DELIVERY, STORAGE, AND HANDLING
- Packaging and Shipping: precast concreteto be palletized, shrink wrapped and marked with legible manufacturer identification, including piece number and quantities.
- Storage and Protectionprecast concreteto be stored in secure area in original packaging.
- Protect from damage by other trades.
- Report all damage due to shipment immediately. Customer is required to sign the Bill of Lading slip detailing the damaged product. Picture proof is required.
1.6WARRANTY
- Foraperiodoftwo(2)yearsfrom delivery of precast concrete, manufacturer warrantstheprecast concreteproductsagainstdefectsinworkmanshipandmaterialsperindustrystandards.Thiswarrantydoesnotcovertheaboveproductsforcrackingandfaultingcausedbysettlingduetoimproperor faulty substrates or improper installation;nordoesitcoverdamagecausedbyimpact,vandalismornaturaldisaster.
PART 2 – PRODUCTS
2.1MANUFACTURERS
- Acceptable Manufacturer:
Tectura Designs, 800-388-8728 Phone: (715) 359-3121 Fax: (715) 355-4627
E-mail: ebsite:
2.2MATERIAL REQUIREMENTS
- Portland Cement: ASTM C-150 Specifications for Portland Cement.
- Aggregates: Aggregate shall be blended to meet individual project requirements.
- Coloring; Pigments used shall be inorganic, resistant to alkalinity and used per manufacturer's
recommendations.
- Reinforcement and Hardware:
- Reinforce precast with deformed rods asrecommended by precast concrete manufacturer.
- Abrasive Inserts: Shall consist of silica sand and epoxy.
- Abrasive Color:______
- Specify one to three lines.
- Setting Materials, Caulks & Sealants
- Color(s) to be selected by Architect.
- Sealer: Colorless, pure acrylic water repellent sealer. Sealer to maintain natural look of concrete surface with no glaze or gloss, darkening or color change.
- Precast manufacturer is not a reseller for any of the above products. Please contact the following supplier for information and recommendations on job specific installation materials:
- Acceptable Supplier:
Custom Building Products/AquaMix, 800-272-878
E-mail: Website:
2.3MANUFACTURED UNITS
- Sizing Tolerances
- All units to conform to shop drawings with a (+/-) 1/8" tolerance in dimension.
- Precast Surfaces and Edges:
- All exposed edges to have minimum of 1/8" radius to prevent chipping.
- All finished surfaces to match approved control sample
- All precast concrete finished surfaces to be factory sealed
PART 3 – EXECUTION
3.1INSPECTION
- Examine substrates for the following:
- Defects or cracks in existing work or substrate.
- Deviations beyond allowable tolerances for the substrate.
- Continue with installation of precast units only when all defects have been corrected.
3.2 PROJECT CONDITIONS
- Do not install products under environmental conditions outside setting material manufacturer's absolute limits.
3.3INSTALLATION
- Precast Tread setting methods include
- Thin Set Application
- Substrateofconcreteorsteel(steelatinteriorapplicationonly). Mustbe withinatoleranceof1/8"inalldimensions.
- Latexmodifiedthinsetmortarusedoverconcretesubstrate.118.4
- Setting bed must be continuous under the entire length of the tread and behind the entire riser. Setting materials utilized per manufactures recommended instruction.
- Epoxythinsetisusedoversteelsubstrate.
- Setting bed must be continuous under the entire length of the tread and behind the entire riser. Setting materials utilized permanufactures recommended instruction.
- Settreadslevelandplumb tomeetfinishednosinglayout.
- Mortar Set Application
- Substrateofconcreteorsteel(steelatinteriorapplicationonly). Mustbe withinatoleranceof1/8"inalldimensions.
- Theheightofthemortar bedisestablishedbasedontreadnosinglayoutmarks and precast thickness.Themortarbedisthenplacedorscreededoverprimedsubstrate.
- Setting bed must be continuous under the entire length of the tread and behind the entire riser. Setting materials utilized per manufactures recommended instruction.
- Settreadslevelandplumb tomeetfinishednosinglayout.
- Tab Set Application
- Substrateofconcreteorsteel(steelatinteriorapplicationonly)mustbewithinatoleranceof1/8"inalldimensions.
- Tabstobesetatfrontandbackoftreadevery12" O.C. minimum.
- Settreadsleveland plumbtoestablishednosinglayout.
- Precast Concrete products setting orinstallation methods are to be reviewed by the manufacturer and setting materials supplier.
- Caulking of Precast
- Cleanall jointsthoroughly,removingalldebris.
- Wipeall jointswithcaulkmanufacturer'srecommendedcleanerpriortoapplication.
- Useurethanecaulk.(Colormatchcaulkto precastperarchitectselection.)
- Cleanupaftercaulkingaspercaulkmanufacturer'srecommendations.
- Final Cleaning of Precast Concrete
- Checkallsurfacesandcaulking,makerepairsas necessary.
- CleantreadswithapHbalancedsoap.
- Protection:
- Upon completion, the work shall be ready for final inspection and acceptance byowner or owner’s agent.
- General Contractor shall protect the finished work from the time the installingcontractor completes the work.
- Finish:
- Overall match to approved sample and per industry standards.
- All products to be factory sealed.
PART 4 – CARE AND MAINTENANCE
4.1
- Cleaning
- Topreserve theappearanceandextendthelifeofthePrecast Concrete cleaning and maintenance processes must be in place. Whenusingthe followingprocedures,pleasefollowtheproductmanufacturer'sinstructionsregardingtheuseofanyequipmentorcleaningmaterialsdescribedhere.
- Powersweep,thenpressurewashprecastsurface.Spotcleananystainedareas.
- Spotcleananystainedareas by using aneutral,non-aggressivecleaner.This may requireefforttoremovesomeofthetoughermarks or stains.
- Exampleofoff-the-shelfcleaners: Citruscleaner,SimpleGreen
- Always startwiththemostneutralcleanerandworkyourwaytowardthemoreaggressivecleaners.
- Inextremecases,contact Tectura Designs to discuss options
- Besuretouseplastic,rubberornylontipequipment;thiswillhelppreventscratchesontheconcrete.
- Precast Concreteisbuilttowithstand aggressivecleaning.However,themoreaggressivethe cleaner,themoreriskisinvolved. Strictadherencetoallproductwarningsissuggested.
- Inallcasesaftercleaningand/orpatching,itisrecommendedthatthePrecastberesealed.Thiswillhelpprotecttheproductfromenvironmental effects.Contactmanufacturertoobtainsealerandstain information based on specific job.
- Maintenance
- Annual maintenance is recommended,however, incasesofextremeuse,thebesttimeforapplicationiswhentheappearanceoftheproductisshowingwearorisappearingdull.
- Checktheprecastforbrokenandchippedpieces.If damaged, contact manufacturer before repairing to order a patch kit and obtain patching procedures.
- De-icingsaltscandamageconcrete, causingthemtoscaleorbreakapart. If necessarythesechemicalsshould beusedsparinglyandwithcautiononourconcreteproducts.
- Salt based products are not recommended
- De-icersshouldbeusedonlywhennecessarytohelploosensnowandice,andmakeremovaleasier. Neverover-applyde-icingproducts.Mixthedeicerswithsandtoincreasetheireffectivenessandreduceoveralluse.
- Alwaysreadand followlabeldirectionswhenapplyingde-icingmaterials.
- Calcium magnesium acetate chloride tends to cause the least amount of damage to Precast Concrete
- Other manufacturer’s products used in conjunction with the Precast Concrete may require additional maintenance.Including but not limited to: Wood, Metals,Plastics, etc. Contact product specific manufactures for their maintenancerequirements.
Rev_1 Updated: June2018
1 | Page
A WAUSAU TILE INC. BRAND