Stage 2 Core Objectives (EPs must report all 17)
- Use computerized provider order entry (CPOE) for medication, laboratory and radiology orders for more than 60% of medication, 30% of lab, and 30% of radiology orders
- Generate and report E-Prescriptions (eRx) using certified EHR technology and compared to at least one drug formulary for at least 50% of all permissible prescriptions
- Record the following demographics for more than 80% of all unique patients: Preferred language, Gender, Race, Ethnicity, and Date of birth
- Record and chart following vital signs as structured data for more than 80% of all unique patients: Height, Weight, Blood Pressure (age 3 and over only), Calculate and display BMI, and plot and display growth charts for patients 0-20 years including BMI
- Record smoking status as structured data for more than 80% if all unique patients 13 years or older
- Implement 5 clinical decision support interventions related to 4 or more clinical quality measures, if applicable, at a relevant point in patient care for the entire EHR reporting period. EP must also enable drug-drug and drug-allergy interaction checks
- Provide more than 50% of all patients with ability to view online, download and transmit their health information within four (4) business days and have more than 5% of all patients view, download, or transmit to a third party their health information
- Provide clinical summaries within one business day for patients for more than 50% of all office visits
- Protect electronic health information created or maintained by the Certified EHR Technology through the implementation of appropriate technical capabilities
- Incorporate more than 55% of all clinical lab test results whose results are either in a positive/negative or numerical format into certified EHR technology as structured data
- Generate at least one reporting listing patients by specific conditions to use for quality improvement, reduction of disparities, research, or outreach
- Use EHR to identify and provide reminders for preventative/ follow-up care for more than 10% of patients with two or more visits in the last two years
- Use EHR to identify and provide patient specific education resources for more than 10% of all unique patients with an office visit
- EP performs medication reconciliation for more than 50% of transitions of care in which the patient is transitioned into the care of the EP
- EP provides a summary of care record for more than 50% of transitions of care and referrals to another setting or provider. 10% must be exchanged through Certified Electronic Health Record Technology (CEHRT) or via an exchange facilitated by an organization that is an organization that is a Nationwide Health Information Network (NwHIN) exchange participant. One or more of these exchanges must take place with a recipient using an EHR designed by a different vendor
- Successful ongoing submission of electronic immunization data from CEHRT to an immunization registry or immunization information system
- A secure message was sent using the electronic messaging function of CEHRT by more than 5% of all patients
Stage 2 Menu Objectives (EP must report 3 of 6)
- Capability to submit electronic syndromic surveillance data to public health agencies and actual submission except where prohibited and in accordance with applicable law and practice
- Record electronic notes in patient records, created, edited and signed by an EP for more than 30% of all unique patients
- More than 10% of all scans and tests whose result is an image ordered by the EP for patients seen during the EHR reporting period are incorporated into or accessible through Certified EHR Technology
- More than 20% of all unique patients seen by the EP during the EHR reporting period have a structured data entry for one or more first-degree relatives or an indication that family health history has been
- Successful ongoing submission of cancer case information from Certified EHR Technology to a cancer registry, except where prohibited by law and practice
- Successful ongoing submission of specific case information from Certified EHR Technology to a specialized registry, except where prohibited by law and practice