SIEMENS APPLICATION INFORMATION FORM – Sitrans FUS
Company: / Name:Address: / Phone:
Fax: / Date:
Country: / E-mail:
For multiple channels please fill out additional forms (include information different than stated here)
1. PIPE: Actual Outer Diameter: inches mm
Wall Thickness: inches mm
<OR> Nominal Pipe Size: inches mm Schedule:
Range of pipe sizes if more than one (Portable)
Pipe Material:
Liner Material: If Other:
Liner Thickness inches mm
Total straight run in pipe diameters:
Number of channels (different pipes to be measured) 1 2 3 4
Number of beams (single measuring point, if known) 2 3 4
For multiple channel meters please fill out one complete form and attached additional forms with different information for each channel: (sections 1, 2, 3, 7)
2. Liquid: List Range of liquids
Name or Description / Viscosity @ TempºC ºF / S.G. or API @ Temp
ºC ºF / Sonic Velocity (if known) / Temp Range
ºC ºF
Min Typ Max / % Solids or Gas / Particle Size
@ / @
@ / @
@ / @
@ / @
For additional liquids use additional comments on Page 3 of 4.
3. Process:
Flow Rate: Min: Max: Typ: Flow Units: Time Units:
Fluid Temp Range: Min: Max:
Flow units to be:
Gross Volume (uncompensated)
<or> Corrected Volume (temperature compensated)
4. Flow Meter Electronics:
Enclosure Desired: Splash Proof IP65, Nema 4X
Flame/Explosion Proof (Nema7)
Weather resistant portable (up to 2 channels/beams only)
(Enclosure will be recommended based on Agency Approval selected)
Agency Approval:
None Required
FM/CSA Class 1, Div 1
Class 1, Div 2
ATEX Zone 0
Zone 1
Zone 2
Protection Type:
Input Power: 90-240VAC 50/60Hz
9-36VDC
Ambient temperature range: Min: Max: ºF ºC
Outputs:
Standard output offering: Enhanced output offering
Communication option: None (standard RS232 serial port)
Modbus
N2
(Communication options subject to area classification)
Tags: Stainless Steel Identification Tags Required
Not Required
5. Sensors:
Agency Approval:
None Required
FM/CSA Class 1, Div 1
Class 1, Div 2
ATEX Zone 0
Zone 1
Zone 2
Protection Type:
If Temperature is required: Clamp-on type Insert type 4-20mA input (customer supplied)
6. Sensor Mounting Tracks:
Standard Aluminum mounting frames
Stainless steel enclosures
Length of unobstructed pipe: Ft Meters
7. Cables:
Length from transducer to flow-meter: Ft meters
Type: Standard Submersible Armored Plenum
8. Environmental Conditions: (check best description)
Sensors: Indoors Outdoors
Corrosive Environment Offshore
Transmitter: Local Mounting at Sensor location Remote Mounting in Protected area.
Portable (kit) Degrees F C Ambient Temp
9. Desired Accuracy:
Accuracy Requested: +/- % of Actual Flow: -or- %Span:
Calibration type required: None Intrinsic NIST traceable Actual water flow cal / STD 4 point
Actual water flow cal / STD 6 point
Special Calibration Requirements:
Additional Comments:CC357-E Rev 3 Page 4 of 4
Use this section to describe your application and for any other additional comments you may have
Signature:______Date:____ / ____ / ____