HEATERS – SURFACE PLANTS

DATA SHEET

INDIRECT FIRED HEATING & VENTILATION UNITS

Project / Rev.
Job No. / By / Date
Title: HEATERS INDIRECT FIRED WARM AIR
Rev. 3 / Rev. 4
Rev. 1 / Rev. 2

1.SPECIFICATIONS

Heater shall conform to:

Vale Engineering Specification SPEC-38007, "Indirect Fired Warm Air Heaters"

Other (Specify)______

2.ENVIRONMENT

Indoor Outdoor: Ambient Temperature Range ___ deg.F

3.CAPACITY

BTU/HR ______CFM ______at ______ESP

Main Fan Motor: ______HP, 1800 rpm, 575/3/60

4.FUEL

Natural Gas at 1000 BTU/FT cubic Supply Pressure: _____

Propane Gas at 2500 BTU/FT cubic Supply Pressure: _____

Provide valve train Single Pipe Double Pipe

5.GENERAL

5.1Heater mounting shall be:

Upright Horizontal

NOTE: Horizontal units shall have burner, valve trains, controls and exhaust mounted on the

Left Right side of the heater facing the discharge.

5.2Insulation

Mineral Fibre Density ______

Rigid Glass Thickness ______

5.3Induced Draft Fan and Motor:

Sized for a stack height of ____ ft.

5.4Air Discharge:

Top Discharge End Discharge Bottom Discharge

Flanged End Plain End 90 deg. Nozzles 45 deg. Nozzles

5.5Fresh Air Inlets:

Left Side Right Side End

Top Bottom Mixing Box

C/W Dampers Motorized Manual

Screened Plain

Service Platform Channel Support

5.5Filters

Disposable ____ Thick ___ Eff. Permanent

5.6Return Air Inlets:

Left Side Right Side End

Top Bottom Mixing Box

C/W Dampers Motorized Manual

5.7Control Panel

Mounted on unit For Remote Mounting (Indoor)

Mounted on unit with Remote Control Panel

Mounted on unit with DCS Interface

5.8For Outdoor Installations, the Weather Enclosure for the Valve Train shall be:

Large Enough to Enclose Valve Train Only

Walk-in Type Insulated Heated to 50 deg.F

5.6Vibration Isolators

Fan Base has spring isolators

Fan Base has Rubber in Shear isolators

Fan Discharge has Flexible Duct Connection

______

5.8Motorized Dampers

Inlet Discharge Not Required

5.9Service Platform

Not Required Required

T-38007Page 1 of 4

6.BURNER AND CONTROLS

Gas Burner - Turn Down Ratio_____

Low Nox Ultra Low Nox Ultra LNOx-Smart Link

Full Modulation

Full Modulation with Space Temperature Override

Hi-Lo-Off DA Controller Honeywell UDC

On-off Flame safeguard Honeywell 7800 w flame rods

Shut-Off Valve

Gas Regulator for Supply Pressure of ______

NOTE: Shut-off valves and primary regulator shall be supplied loose.

7. START-UP SERVICE

Included Not Included

8. CHECK ALL THAT APPLY

Main Blower BI-AF

Main Blower DWDI – Single Blower

Main Blower DWDI – Duel Blowers with Shaft coupled

Main Blower Bearings Slit Pillow Block L10=100,000 hrs

Main Blower Motor IEEE 841

9.SPECIAL FEATURES or Deviations to the STANDARD

List: ______

______

______

T-38007Page 1 of 4