Tender specification for programmable Power Supply
Programmable Power Supply SYSKON Series P 4500 - K364A
Housing: Desktop, suitable for rack-mounting
19" (447mm) x 4HU (177mm+14mm) x 501 mm (+40mm) (W x H x D)
AC mains: 3x230/400 V ~ +10 / –15 %, 47 ... 63 Hz 16-A-connection clamps Power factor correction
Electrical safety: Protection class I
Overvaltage category II for AC mains
Overvoltage category I for output and interfaces
Pollution level 2
EN 61010-1 / 2001
EMC: EN 61326-1:2006, Industrial usage
Output: Rails with drilled holes for screws M6 or M8 and diameter 4 mm Prated 4500W, Urated 60V, Irated 180A
Output electrical data: Floating output with safe electrical separation towards AC mains and interfaces;
max. allowed potential output-earth 120V
Modes: adjustable constant voltage or constant curent source with automatic sharp changeover
Setting time: 0V --> Urated 7ms; 19ms no load; full load
Urated --> 1V 70ms; 11ms no load; full load
Dynamic sink for quick fall time
Setting precision: 0,1% + 60mV
0,15% + 180mA
Setting resolution: 1mV
3,125mA
Analogue Interface: 20-pin interface with screw terminals
Auxiliary voltage, 2 x Trigger, nominal voltage set& actual voltage monitoring , nominal current set and actual current monitoring, Master-/Slave function Sense-input with autosensing and voltage reversal protection 3 x signal output (2 are floating)
Digital interface: RS-232C-Interface
USB Interface
IEC-625 / IEEE-488 interface (optional)
Codes and formats according to IEEE 488.2
Adjustable functions and parameters:
Voltage (nominal & high/low limit), Current (nominal & high/low limit) Output on/off
over voltage protection level (with/without switch-off, delay time) over current protection level (with/without switch-off, delay time)
Mains power on options: reset, recall, standby
Lockable front elements (per hand, Trigger, digital)
Trigger function: optocoupler
selectable trigger action
Trigger action: output on/off, sequence start/stop
recall of saved settings
Locking of front elements
Memory: 1700 parameters and 15 complete set-ups can be saved
Accessable information: Measuring of output voltage, current and power Extremal value memory
Sequence function: Generation of voltage and current curves with up to 1700 setting points Sequences can be chained
Including DaKKs calibration certificate
Interface accessory
IEEE488 Interface, insertable, order no. K384A
Brand: Gossen Metrawatt
Country of Origin: Made in Germany
Manufacturer: GMC-I Messtechnik GmbH
Südwestpark 15
D-90449 Nürnberg
Tel.:0911-8602-111; FAX 0911-8602-777
E-Mail:
www.gossenmetrawatt.com