AC steady state
In general, the solutions for the voltages and currents in a circuit containing resistors, capacitors and inductors (in short, all linear behaving components) are solutions to a linear ordinary differential equation. It can be shown that if the voltage and/or current sources in the circuit are sinusoidal and of constant frequency, the solutions tend to a form referred to as AC steady state. Thus, all of the voltages and currents in the circuit are sinusoidal and have constant peak amplitude, frequency and phase.
Let v(t) be a sinusoidal function of time with constant amplitude Vp, constant frequency f, and constant phase φ.
where j represents the imaginary unit () and means the real part of the complex number z.
Now, let the complex number V be given by:
V is called the phasor representation of v(t). V is a constant complex number. For a circuit in AC steady state, all of the voltages and currents in the circuit have phasor representations as long as all the sources are of the same frequency. That is, each voltage and current can be represented as a constant complex number. For DC circuit analysis, each voltage and current is represented by a constant real number. Thus, it is reasonable to suppose that the rules developed for DC circuit analysis can be used for AC circuit analysis by using complex numbers instead of real numbers.
Definition of electrical impedance
The impedance of a circuit element is defined as the ratio of the phasor voltage across the element to the phasor current through the element:
It should be noted that although Z is the ratio of two phasors, Z is not itself a phasor. That is, Z is not associated with some sinusoidal function of time.
For DC circuits, the resistance is defined by Ohm's law to be the ratio of the DC voltage across the resistor to the DC current through the resistor:
where the VR and IR above are DC (constant real) values.
Just as Ohm's law is generalized to AC circuits through the use of phasors, other results from DC circuit analysis such as voltage division, current division, Thevenin's theorem, and Norton's theorem generalize to AC circuits.
The full electric impedance is equal to:
,
where
is the real part of the complex electric impedance, named the effective electric impedance, and
is the imaginary part of the complex electric impedance, named the reactive electric impedance.
Impedance of different devices
For a resistor:
For a capacitor:
For an inductor:
For derivations, see Impedance of different devices (derivations).
Reactance
See main article: Reactance
The term reactance refers to the imaginary part of the impedance. Some examples:
A resistor's impedance is R (its resistance) and its reactance is 0.
A capacitor's impedance is j (-1/ωC) and its reactance is -1/ωC.
An inductor's impedance is j ω L and its reactance is ω L.
It is important to note that the impedance of a capacitor or an inductor is a function of the frequency ω and is an imaginary quantity - however is certainly a real physical phenomenon relating the shift in phases between the voltage and current phasors due to the existence of the capacitor or inductor. Earlier it was shown that the impedance of a resistor is constant and real, in other words a resistor does not cause a phase shift between voltage and current as do capacitors and inductors.
When resistors, capacitors, and inductors are combined in an AC circuit, the impedances of the individual components can be combined in the same way that the resistances are combined in a DC circuit. The resulting equivalent impedance is in general, a complex quantity. That is, the equivalent impedance has a real part and an imaginary part. The real part is denoted with an R and the imaginary part is denoted with an X. Thus:
Req is termed the resistive part of the impedance while Xeq is termed the reactive part of the impedance. It is therefore common to refer to a capacitor or an inductor as a reactance or equivalently, a reactive component (circuit element). Additionally, the impedance for a capacitance is negative imaginary while the impedance for an inductor is positive imaginary. Thus, a capacitive reactance refers to a negative reactance while an inductive reactance refers to a positive reactance.
A reactive component is distinguished by the fact that the sinusoidal voltage across the component is in quadrature with the sinusoidal current through the component. This implies that the component alternately absorbs energy from the circuit and then returns energy to the circuit. That is, unlike a resistance, a reactance does not dissipate power.
It is instructive to determine the value of the capacitive reactance at the frequency extremes. As the frequency approaches zero, the capacitive reactance grows without bound so that a capacitor approaches an open circuit for very low frequency sinusoidal sources. As the frequency increases, the capacitive reactance approaches zero so that a capacitor approaches a short circuit for very high frequency sinusoidal sources.
Conversely, the inductive reactance approaches zero as the frequency approaches zero so that an inductor approaches a short circuit for very low frequency sinusoidal sources. As the frequency increases, the inductive reactance increases so that an inductor approaches an open circuit for very high frequency sinusoidal sources.
Combining impedances
Combining impedances in series, parallel, or in delta-wye configurations, is the same as for resistors. The difference is that combining impedances involves manipulation of complex numbers.
In series
Combining impedances in series is simple:
In parallel
Combining impedances in parallel is much more difficult than combining simple properties like resistance or capacitance, due to a multiplication term.
In rationalized form the equivalent resistance is:
See also Series and parallel circuits.
Circuits with general sources
Impedance is defined by the ratio of two phasors where a phasor is the complex peak amplitude of a sinusoidal function of time. For more general periodic sources and even non-periodic sources, the concept of impedance can still be used. It can be shown that virtually all periodic functions of time can be represented by a Fourier series. Thus, a general periodic voltage source can be thought of as a (possibly infinite) series combination of sinusoidal voltage sources. Likewise, a general periodic current source can be thought of as a (possibly infinite) parallel combination of sinusoidal current sources.
Using the technique of Superposition, each source is activated one at a time and an AC circuit solution is found using the impedances calculated for the frequency of that particular source. The final solutions for the voltages and currents in the circuit are computed as sums of the terms calculated for each individual source. However, it is important to note that the actual voltages and currents in the circuit do not have a phasor representation. Phasors can be added together only when each represents a time function of the same frequency. Thus, the phasor voltages and currents that are calculated for each particular source must be converted back to their time domain representation before the final summation takes place.
This method can be generalized to non-periodic sources where the discrete sums are replaced by integrals. That is, a Fourier transform is used in place of the Fourier series.
Magnitude and phase of impedance
Complex numbers are commonly expressed in two distinct forms. The rectangular form is simply the sum of the real part with the product of j and the imaginary part:
The polar form of a complex number the real magnitude of the number multiplied by the complex phase. This can be written with exponentials, or in phasor notation:
where
is the magnitude of Z (Z* denotes the complex conjugate of Z), and
is the angle.
Peak phasor versus rms phasor
A sinusoidal voltage or current has a peak amplitude value as well as an rms (root mean square) value. It can be shown that the rms value of a sinusoidal voltage or current is given by:
In many cases of AC analysis, the rms value of a sinusoid is more useful than the peak value. For example, to determine the amount of power dissipated by a resistor due to a sinusoidal current, the rms value of the current must be known. For this reason, phasor voltage and current sources are often specified as an rms phasor. That is, the magnitude of the phasor is the rms value of the associated sinusoid rather than the peak amplitude. Generally, rms phasors are used in electrical power engineering whereas peak phasors are often used in low-power circuit analysis.
In any event, the impedance is clearly the same whether peak phasors or rms phasors are used as the scaling factor cancels out when the ratio of the phasors is taken.
Matched impedances
When fitting components together to carry electromagnetic signals, it is important to match impedance, which can be achieved with various matching devices. Failing to do so is known as impedance mismatch and results in signal loss and reflections. The existence of reflections allows the use of a time-domain reflectometer to locate mismatches in a transmission system.
For example, a conventional radio frequency antenna for carrying broadcast television in North America was standardized to 300 ohms, using balanced, unshielded, flat wiring. However cable television systems introduced the use of 75 ohm unbalanced, shielded, circular wiring, which could not be plugged into most TV sets of the era. To use the newer wiring on an older TV, small devices known as baluns were widely available. Today most TVs simply standardize on 75-ohm feeds instead.
Inverse quantities
The reciprocal of a non-reactive resistance is called conductance. Similarly, the reciprocal of an impedance is called admittance. The conductance is the real part of the admittance, and the imaginary part is called the susceptance. Conductance and susceptance are not the reciprocals of resistance and reactance in general, but only for impedances that are purely resistive or purely reactive.
Electrical conductance is the reciprocal of electrical resistance. It is a measure of how easily electricity flows along a certain path through an object. The SI derived unit of conductance is the siemens (symbol S, equal to 1/Ω; alias the "mho"). Oliver Heaviside coined the term in September 1885.
Electrical conductance should not be confused with conduction, which is the mechanism by which charge flows, or with conductivity, which is a property of a material.
Relation to other quantities
Conductance is related to susceptance and admittance by the equation:
where:
· Y is the admittance, measured in siemens
· G is the conductance, measured in siemens
· is the imaginary unit
· B is the susceptance, measured in siemens
The magnitude of admittance is given by:
In electrical engineering, the admittance (Y) is the inverse of the impedance (Z). The SI unit of admittance is the siemens. Oliver Heaviside coined the term in December 1887.
where
Y is the admittance, measured in siemens
Z is the impedance, measured in ohms
Just as impedance is complex resistance, and the conductance G is the inverse G = 1/R of resistance R, admittance is also complex conductance.