Stand alone Access Controller profile

Dimensions / 105(L)×105(W)×30(H)mm / Door bell output / Yes
Package dimensions / 127(L)×127(W)×36(H)mm / Tamper alarm / yes
Net weight / 148g / External reader connector / No
Package weight / 207g (including controller) / Door open relay time / 0-99 Sec.
Color / Gray / Register a card on keypad / Yes
PC & software / No / Delete a card on keypad / Yes
Keypad programmable / Yes / Power consumption / 12V 200mA
Access mode / Card, Pin, Card + pin / Housing material / ABS
Indicator / 3 LEDS and a beeper / Temperature range / -20℃-70℃
Keypad backlighting / Yes / Humidity range / 10%-90%
Built-in reader type / EM card / OEM
Reading distance / 3 inches (8-10cm) / Exit button input / Yes
Card capacity / 1,000
Electric locks type / Magnetic, electric bolt, electric strike


Operations Instructions:

1.Initialization or Reset operation:

Press the key “K14” of the circuit board and the buzzer will ring twice to initialize

the system. (Original password-123456)

2.Start Setting(the original setting remains OFF):

Put the jumper on J1,means the setting of the electric lock terminal as NC, otherwise means

NO.

3.Entering into the Programming mode:

Press the Key “#” (function key)for 4 times, the green, yellow, red LED will beturned on

Input the 6 digit programming password(original 123456),then red and green LED

remain ON while yellow OFF,If not, please re-input the password.

Key “1”: Renew the programming password

  1. Press Key “1”under programming mode, the red and the green LED off, the yellow LED on.
  2. Input a new 6 password. If success, the buzzer will ring with a long –lasting “Bi”. Then the

red and the green LED on while yellow off..

c. Press key “*” to ESC.

Note:The new password should be carefully reserved in case of re-entering the programming

mode. In case of the password being forgotten or stolen, Please executeinitialization or reset

operation 1.

Key “2”:Register individual card and password(for each ID card)

  1. Press Key “2”under programming mode, the yellow LED off, while the green and red LED

flash.

  1. Reading the ID card, the buzzer “Bi” will ring once. The red and the green LED off, the

yellow on.

  1. Input the 4 digits (such as your serial numbers, ****), the buzzer “Bi” willring once. The

red and the green LED flash, the yellow LED off. That means the operator has successfully

registered one ID card. To register the other cards,please repeat step b, c.

  1. Press key “*” to ESC.(When the buzzer rings “Bi- Bi” twice, it indicates that youare

repeatedly registering the same card.)

Note: To open the door with password, please input the last two digits of the first groupof 10

digits and then the user’s 4 numbers (such as your serial number),(For example,if the

card attached number is 0000603684 16308202(18 digits),the opening password is

84**** ).

With correct password, the yellow LED will be on and then green LED remainslasting on.

Key “3”:Cancel individual card

  1. Press Key”3”under programming mode, the buzzer will ring “Bi” once, then the

yellow LED on, the green and the red LED off.

  1. Input the last 6 digits of the first group of 10 digits (card attached number )which you

want to delete(For example, the card number is 0000603684, simply to input 603684),then

the yellow LED off, the green and the red LED on .

1