EQUIPMENT SUMMARY

DRIVERBASE OFFERING

MAKE / MODELCaterpillar

RATED HORSEPOWER95 HP

COOLER HORSEPOWER7 HP

AMBIENT TEMPERATURE DERATENIL

ELEVATION DERATE0

SITE HORSEPOWER (CHP)88 HP

R.P.M.1800 RPM

COMPRESSOR

MAKE / MODELGardnerDenver SSH

NUMBER OF STAGES1

PACKAGE

ENGINEERED CONSTRUCTION AND ASSEMBLY.

COOLER:GHT or equal

PANEL:Spartan/Murphy

DATA BOOKS:DATA BOOK SUPPLIED WITH UNIT

CATERPILLAR 3304NA ENGINE FEATURES

  1. Inlet air filter (manufacturer’s standard dry)
  1. Muffler: Silex hospital grade
  1. Altronic III ignition system CSA approved
  1. Oil filter system (manufacturer’s standard)
  1. Fuel system regulator c/w block and vent
  1. Governor
  1. TDI low pressure Gas Starter
  1. 15 gallon lube oil day c/w level maintainer
GHT 2300 COOLER FEATURES
  1. Direct drive from front of engine
  1. Manual Louvers
  1. 400 psig maximum gas and oil sections
  1. CRN registered oil and gas oil sections

GARDNERDENVER SSH COMPRESSOR FEATURES

  1. 177 mm rotary screw gas compressor
  1. 375 psig maximum discharge pressure
  1. 50 psig maximum suction pressure
  1. Turn valve capacity controller
  1. Large oversized tapered roller bearings
  1. Oil pump included

PACKAGING

SKID

Fabricated steel skid utilizing 8” @ 19# wide flange. 8’6” wide x 17’ long OA. Skid main members filled with concrete. Skid top covered with ¼” checker plate. Waste oil containment tanks are included on outside of skid.

INLET CONTROL VALVE

1 only Kimray 2” 150# inlet control valve

INLET SEPARATOR

1 only 16” O.D. x 60” mesh pad inlet separator

-230 psig design @ 250 degrees F

-1/16” corrosion allowance, code radiography

-3” 150# RF process connections

-1 only Murphy L1200 high level shutdown

-1 only Jerguson reservoir indicator

-1 only Fisher automatic drain

-1 only Taylor pressure relief valve set @ 230 psig

GAS SEPARATOR

1 only 16” O.D. x 53” coalescing gas / oil separator

-300 psig design @ 250 degrees F

-1/16” corrosion allowance, code radiography

-2” npt process connections

-1” NPT oil connection

-pleated type separator element

-Murphy L1200 low level shutdown

-1 only Taylor pressure relief valve set @ 300 psig

-1 only Jerguson reservoir indicator

PROCESS PIPING

-3” 150# inlet piping from skid edge to compressor inlet, 1/16” corrosion allowance, 10% radiography

-2” npt discharge piping from compressor discharge through to unit discharge 1/16” corrosion allowance

-2” relief valve vent header, tying the process relief to a common header and 1” 3000# union skid edge connection

-1” valve for manual start up bypass

OIL SYSTEM

Compressor lube system includes:

-400 psig oil section

-FPE thermostatic valve for oil temperature control

-One Wika differential gauge

-Dual element 10 micron oil filters

MAXIMUM PRESSURE BYPASS VALVE

1 only Fisher 4150 maximum pressure valve

MINIMUM PRESSURE BYPASS VALVE

1 only Kimray 1” npt minimum pressure valve

START SYSTEM

1” 3000# starter system

-quick opening manual start gas valve

-1” start gas regulator

-alternate supply piping to skid edge

-TDI turbine type starter

-exhaust tubing to eave height

FUEL SYSTEM

1” 3000# NPT fuel gas line complete with:

-Fisher 1” high pressure fuel gas regulator

-Murphy fuel gas block and vent valve

-Safety relief valve

-alternate supply piping to skid edge

-Fisher low pressure regulator

-1” NPT fuel gas manual shut off

-fuel gas scrubber with coalescing element

ENGINE UTILITIES

Jacket water system comprises an engine mounted radiator c/w a pusher fan and pull fan.

COOLER DRIVE SYSTEM

Cooler is direct driven from the front of the engine. The engine and cooler drives covered by a removable guard.

PAINT

All bare steel painted with one coat primer and one coat enamel paint.

ALIGNMENT

Direct drive is included and will be fully shop aligned. Alignment to be checked in field before start up.

CONTROL PANEL

Control panel is provided and is equipped to operate on sweet instrument gas. Panel board supplied as follows:

One Spartan/Murphy Control System

Panel TypeMurphy

Approved for Class 1, Div. 2, Group C/D

Item #1:ONE ONLY MURPHY SERIES “TTDJ” ELECTRONIC PROTECTION AND CONTROL SYSTEM

(Division 2 application)

Panel TypeMurphy

Ignition power supply

20 intrinsically safe channels

Class A, B and C shutdowns

TachometerMurphy DTHO-1200 tachometer, hour meter and overspeed shutdown

Enclosure24” x 24” front access panel

Paint ASA61 Grey

Process GaugesTwo Murphy OPLFC-A-xxxx switch gauges for indication and shutdown of:

-High/Low Suction Pressure

-High/Low Discharge pressure

Utility GaugesTwo Murphy A25P-100 switch gauges for Eng. and Comp oil pressure.

Two Murphy A25T-250 switch gauges Comp Oil and Eng JW temperature.

NOTE:The panel will be built to Canadian Electrical Code Standard for a Class I Group D Division 2 hazardous area. The panel will be provided with CSA approval. Gas detection is not included.

ELECTRICAL

Hook up of all I/S wiring from end devices to control panel.

All other electrical by others. Gas detection is not included and is extra.

HEATERS

Dual 12000 BTU/hr CCI catadyne heaters c/w thermostats and regulators.

BUILDING

8’6”’ wide x 14’ self framing type building complete with:

-pre painted exterior, colours to be advised

-two (2) double doors c/w closer, panic hardware and windows

-two wall louvers 24” x 24”

-R12 insulation

-Summer/winter recirculation system

-40” x 40” dual pane sliding window

-white interior building liner

LUBRICANTS AND COOLANTS

All compressor and engine coolants are not included and are extra.