Wall protection cladding with HPL compact boards, invisible fixed using a support profile of aluminum and a three-sided cover profile with powder coated or anodized aluminum.
Manufacturer: Wall protection, type 24
Brem Systeme GmbH, Boschstraße 7, 94405 Landau
Tel. 09951/ 6903-0, Fax 09951/ 6903-25
RM
Wall protection, to be produced of high pressure laminate (HPL)
(Board characteristics according to DIN EN 438 2)
The offered product has to be produced in any case according to the application recommendations of the producer of decorative laminates (GKV: Wall cladding version November 1998).
Color and structure of the compact board is to be chosen by the building owner, the wall protection is to be invisible mounted on gypsum cardboard, brick walls or solid walls. The mounting is effected with at least two lines placed one above the other, end-to-end support profiles made of aluminum. The bottom support profile offers removal protection. The panels have to be mounted in horizontal direction offering enough space for the upper and bottom end. The cover profile is being installed on three sides to the panel without any seam. The front visible edge of the covering profile is 5mm around the cover profile. It is necessary to allow ventilation of the system which means that there is air between the bottom support profile and the wall and the other way around as long as the cover profile is seamed to the wall. In order to prevent the board to extend differently (to dish), please check if the temperature behind the board is almost the same as in front of the board. The panels are beveled, grooved and connected with a black spring.
Dimensions:Panel thickness:9mm
Depth:17mm
Panel height variable:650mm
Panel raster width/panels1250mm / 100–1250mm
Cover profile alu:5 x 17mm
Color and powder coating to be selected
Installation:
The wall protection has to be installed flush.
Furthermore, it has to be checked whether a moisture barrier has to be installed to the wall. Therefore, a measurement has to be effected having sole responsibility. The wall humidity is to have a value of between 0.4% up to 1% as maximum. The air humidity in the wall (microclimate) and within the corridor or room is to be identical (40%-60%). The room temperature should be the usual temperature (23°C).
As a rule drywall construction do not obtain any wall humidity. Please consider that the boards should have the same temperature during installation as the usual room temperature (23°C).
Consequently, please use appropriate dowels e.g. nylon as well as corrosion-free screws which correspond to the requirements of the underground.
The wall mounting has to be jointed elastically using silicone. Color is to be chosen by the building owner. The elastic joint seal has to be calculated to the standard price.
Unit
Side ending, to be additionally produced for wall protection type 24.
The upper cover profile is slot as miter joint and cracked to the side in order that no open miter joint can occur. The miter joint is glued additionally. The cover profile is provided to the bottom edge of the bottom support profile.
Unit
Outer edge 90°/135°, made of a compact part, to be additionally produced for wall protection type 24.
The outer edge has to be installed flush to the wall protection system. The edge of the upper cover profile is produced with a leg of 100mm which is adjusted to the edge of the cross section of the compact part. The edge form of the cover profile has to be powder coated prior to be welded and cleanly dressed. The outer edge has to be additionally embedded in silicone in order to smooth impact loads. The vertical joint to the neighboring panel is to be installed as described in wall protection type 24.
Dimensions:HPL thickness:9mm
Side length:60mm
Outer diameter:20mm
Height variable:650mm
Unit
Outer edge in a special angle of 30°-160°, made of a compact part to be additionally produced for wall protection type 24.
Installation as described in outer edge 90°/135°.
RM
Alternative position
Outer edge 90°/135°, made of a 3mm thick stainless steel part, finely brushed, to be additionally produced for wall protection type 24.
The outer edge has to be installed flush to the wall protection system. The edge of the upper cover profile is produced with a leg of 100mm which is adjusted to the edge of the cross section of the compact part. The edge form of the cover profile has to be powder coated prior to be welded and cleanly dressed.
The stainless steel part is doubled on the backside and is to be embedded in silicone in order to smooth impact loads. The vertical joint to the neighboring panel is to be installed as described in wall protection type 24.
Dimensions:HPL thickness:9mm
Side length:60mm
Outer diameter:20mm
Height variable650mm
RM
Alternative position
Outer edge in a special angle of 30°-160° made of a 3mm thick stainless steel part, to be additionally produced for wall protection type 24.
Installation as described in outer edge 90°/135°.
Unit
Inside edge 30°-180°, to be additionally produced for wall protection type 24.
Panels are to be pushed bluntly. The upper and the bottom cover profile have to be mitered from the inside edge. Starting at 135° the inside edge have to be additionally connected using an end-to-end spring.
Unit
Cutout for power sockets, to be additionally produced for wall protection type 24.
Circular cut D 68mm including rounded edges.
Alternative position
Cutout for power sockets, to be additionally produced for wall protection type 24.
The power socket is based with a flame laminate of 3mm. The flame laminate has the same décor and the same surface like the wall protection board. The base board is being provided to the electrician prior to installation of the power socket. The wall protection has to be recessed approx. 20mm larger than the dimensions of the power socket. The edges of the gap have to be beveled.
For single sockets: cutout approx.120mm x 120mm
base board160mm x 160mm with one drilling
D=68mm
For double sockets:cutout approx.120mm x 200mm
base board160mm x 240mm with two drillings
D=68mm
Unit
Gap for service, to be additionally produced for wall protection type 24.
In the case of gaps for service which do not reach the ground an additional panel is being installed to the wall protection using a connection spring.
Unit
Tableau cutout, to be additionally produced for wall protection type 24.
The edge of the cutout is beveled with an aluminum frame.
Unit
Contingency
Tableau cutout, to be additionally produced for wall protection type 24.
The edge of the cutout is beveled with a stainless steel frame.
Unit
Cutout, to be additionally produced for wall protection type 24.
For built-in units of 400mm x 400mm up to 0.16m².