CapitalAssetManagement–AssetStrategies
1701–4555Kingsway
Burnaby,B.C.,
V5H4V8Fax:(604)454-2098
Web:
FACILITY CONDITION INDEX
FacilityConditionIndex(FCI)isanindustrystandardassetmanagementtoolwhichmeasuresthe“constructedasset’sconditionataspecificpointintime”(USFederalRealPropertyCouncil,2008).Itisafunctionalindicatorresultingfromananalysisofdifferentbutrelatedoperationalindicators(suchasbuildingrepairneeds)toobtainanoverviewofabuilding’sconditionasanumericalvalue.
ItwasdevelopedbytheUSNavytoassessconditionsofvesselsandstrategicallyprioritizerenewalspending.FCIwasfirstutilizedasanindexfordeterminingbuildingconditionintheearly1990sbyUSNationalAssociationofCollegeandUniversitiesandquicklybecamethestandardforpostsecondaryinstitutionsacrossNorthAmerica.RecentlyconditionindexmeasureshavebeenadoptedbytheUSFederalRealPropertyCouncil,AmericanPublicWorksAssociation,CouncilofOntarioUniversities,FederationofCanadianMunicipalities(throughtheirInfraguidepublications),HealthAuthorities,EducationMinistriesandSocialHousingAuthoritiesthroughoutNorthAmerica.
FCIisobtainedbyaggregatingthetotalcostofanyneededoroutstandingrepairs,renewalorupgraderequirementsatabuildingcomparedtothecurrentreplacementvalueofthebuildingcomponents.Itistheratioofthe“repairneeds”toreplacementvalue”expressedinpercentageterms.LandvalueisnotconsideredwhenevaluatingFCI.
ThelowerthevalueofFCI,thebetterconditionthatabuildingisin.CurrentindustrybenchmarksindicatethefollowingsubjectiveconditionratingsforfacilitieswithvariousrangesofFCI:
0‐5%FCI / Assetisingoodcondition5‐10%FCI / Assetisinfair
condition
10–30%FCI / Assetisinpoor
condition
Forexample,abuildingwithareplacementvalueof$1,000,000withoutstandingrenewalneedsof$90,000wouldhaveanFCIof9%,indicatingthebuildingisinfaircondition.FCIcanbereportedatalllevelsintheassethierarchy;itcanbeusedtoexpresscomponentcondition
(example:elevators),buildingcondition,developmentconditionandportfoliocondition,witheachhigherlevelbeingtheaggregateofthosebeneathitinthehierarchy.
WhileoriginallydevelopedbytheUSNavy,FCIwasquicklyadoptedbyuniversitiesandotherpublicinstitutionstomonitorbuildingconditionandemployedasastrategicdecision‐makinginvestmenttool.OtherorganizationsinCanadaareadoptingthistoolandareatvariousstagesofimplementation.ThisindicatorisanalogoustotheconditionindexemployedformanyyearsbytheMinistryofTransportationtomonitorconditionofbridgesintheprovince,usedtoidentifyandprioritizerepairs.BCHousingiscurrentlyusingFCItoassistwithinvestmentdecisionsandstrategicdirections.
FCIIMPACTS,RISKS RESIDENT MORALE
UtilizingFCIprovidesaprofessionalmethodofmeasurementtodeterminetherelativeconditionindex ofasingle building, groupof buildings, or if desired, a totalportfolio.AsFCIincreases, theassetswillexperience:
- Increasedriskofcomponentfailure
- Increasedfacilitymaintenanceandoperatingcosts
- Greaternegativeimpactstostaffandresidents.
Table1onthefollowingpageillustratesthetypesofrisksandtradeoffsthatcanbeexpectedwhenbuildingsaremaintainedatdifferentFCIlevels.
Table 1:FacilityCondition Index Levels and Impact to Component Failure Risk, ResidentsandStaff
CommonImplicationsofFCItoHousingPortfoliosFCI
Levels / ImpacttoBuildingsandComponents / Examplesof ComponentIssues / ResidentComplaintsandMorale / MaintenanceStaffImpact
Critical(Over 30%) / ‐ Facilitieswill lookwornwithobviousdeterioration.
‐ Equipmentfailureoccurringfrequently. Occasional buildingshut downwill likelyoccur.Management riskis high.
‐ Health and safetyissuefigureprominently / ‐ Replacement ofmultiplesystems required (i.e.
Mechanical, Electrical,Architecturaland Structural
‐ Building heatingsystemfailure.
‐ Evacuationof upper floordue to unaddressedroofleakage.
‐ Structuralissues includingenvelopereplacement. / ‐ Resident complaints will be very high withan unmanageable levelof frequency.
‐ Lack ofmaintenance willaffect resident attitudes and morale. / ‐ Staff will not beable to provideregular scheduled maintenancedue to high levelof“reactive”calls
Poor(11% to 30%) / ‐ Facilitieswill lookwornwith apparentand increasingdeterioration
‐ Frequentcomponent and equipment failuremay occur.Occasionalbuildingshut downwilloccur / ‐ Replacement ofspecificmajorsystems required, suchas heatingand plumbingsystems,complete interiorrenovations,buildingenveloperestoration.
‐ Shut downmay affect someunits (i.e.roofor pipeleakage) / ‐ Resident complaints will be high withincreasedleveloffrequency.
‐ Concernabout negativeresidentmoralewill be raisedand becomeevident. / ‐ Facilitiesstafftimewill likelybedivertedfromregular scheduled maintenanceand forcedto“reactive”mode
Fair(6% to 10%) / ‐ Facilitiesarebeginningto showsigns ofwear
‐ More frequentcomponent and equipment failurewilloccur / ‐ Repairs and replacement ofspecificsystems,i.e.boiler,window replacements,interiorrenovations. / ‐ Resident complaints will occur withhigher leveloffrequency
‐ Resident moralemay be affected / ‐ Facilitiesstafftimemay attimes be divertedfrom regularscheduled maintenance
Good(0% to 5%) / ‐ Facilitieswill lookclean and functional
‐ Limitedandmanageable component and equipment failuremayoccur / ‐ Repairs and replacement ofmoreof an aestheticorgeneralnature,such as wallpainting,carpet replacement, roofrepair,window caulking. / ‐ Resident complaints will be low andmanageable
‐ Resident moralewill be positiveandevident / ‐ Facilitiesstafftimewill bedevotedtoregular scheduled maintenance