EMC TEST REPORTReport No. : EC5NS005
CE EMC TEST REPORT
Equipment5-Port Gigabit Desktop Switch
Model No.
ES-5500P, GS-G05P
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan, R.O.C.
The test result refers exclusively to the test presented test model / sample.
Without written approval of SPORTON International Inc., the test report shall
not be reproduced except in full.
This test report is only applicable to European Community.
/ SPORTON International Inc.6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
EMC TEST REPORTReport No. : EC5NS005
Table of Contents
History of this test report
CERTIFICATE OF COMPLIANCE
1.General Description of Equipment under Test
1.1.Basic Description of Equipment under Test
1.2.Feature of Equipment under Test
2.Test Configuration of Equipment under Test
2.1.Test System
3.Test Software
4.General Information of Test
4.1.Test Facility
4.2.Test Voltage
5.Test of Conducted Powerline
5.1.Typical Test Setup Layout of Conducted Powerline
5.2.Typical Test Setup Layout of disturbances at telecommunication ports
5.3.Test Procedure
5.4.Test Result of AC Powerline Conducted Emission
5.5.Test Result of Disturbances at Telecommunication Ports
6.Test of Radiated Emission
6.1.Test Procedure
6.2.Test Result of Radiated Emission
7.Harmonics Test
8.Voltage Fluctuations Test
8.1.Standard
8.2.Test Procedure
8.3.Test Setup
8.4.Test Record
9.Electrostatic Discharge Immunity Test (ESD)
9.1.Test Setup
9.2.Test Procedure
9.3.Test Record
10.Radio Frequency Electromagnetic Field Immunity Test (RS)
10.1.Test Setup
10.2.Test Procedure
11.Electrical Fast Transient/Burst Immunity Test (EFT/BURST)
11.1.Test Setup
11.2.Test Procedure
12.Surge Immunity Test
12.1.Test Procedure
12.2.Test Record
13.Conducted Disturbances Induced by Radio-Frequency Field Immunity Test ( CS )
13.1.Test Procedure
13.2.Test Setup
14.Power Frequency Magnetic Field Immunity Tests
14.1.Test Record
14.2.Test Procedure
14.3.Test Setup
15.Voltage Dips and Voltage Interruption Immunity Tests
15.1.Test Record of Voltage Interruption
15.2.Test Record of Voltage Dips
15.3.Test Procedure
16.List of Test Instrument
Appendix A. Test Photographs ...... A1 ~ A5
Appendix B. Photographs of EUT...... B1 ~ B13
History of this test report
Original Report Issue Date: Dec. 05, 2005
■ No additional attachment.
□ Additional attachment were issued as following record:
Attachment No. / Issue Date / Description/ SPORTON International Inc. / Page Number / : / 1
TEL : 886-2-2696-2468 / Issued Date / : / Dec. 05, 2005
FAX : 886-2-2696-2255
EMC TEST REPORTReport No. : EC5NS005
Certificate No. : EC5NS005
CERTIFICATE OF COMPLIANCE
Equipment5-Port Gigabit Desktop Switch
Model No.
ES-5500P, GS-G05P
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan, R.O.C.
I herebycertify that :
The measurements shown in this test report were made in accordance with the procedures given in European Council Directive 89/336/EEC.
The equipment was passed the test performed according to
European Standard EN 55022:1998/A1:2000/A2:2003 Class B,
EN61000-3-2:2000, EN61000-3-3:1995/A1:2001and
EN 55024:1998/A1:2001/A2:2003
( IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002,
IEC 61000-4-4:1995/A2:2001, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000,
IEC 61000-4-8:1993/A1:2000, IEC 61000-4-11:1994/A1:2000 ).
The test was completed on Dec. 01, 2005.
______
Alex Chen
Manager
SPORTON International Inc.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd.,
Hsi Chih, Taipei Hsien, Taiwan, R.O.C.
1.General Description of Equipment under Test
1.1.Basic Description of Equipment under Test
STP Cable: Shielded, 10.0m
STP Cable: Shielded, 1.0m
Power Supply Type: Linear
AC Power Input: Wall-mount, 2pin
DC Power Cable: Non-Shielded, 1.8m, 2pin
1.2.Feature of Equipment under Test
Please refer to user manual.
2.Test Configuration of Equipment under Test
2.1.Test System
< EMI >
Support Unit 1. -- Personal Computer (hp compaq)– for local workstation
FCC ID: N/A
Model No.: d330uT
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0014
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 2. -- Monitor (COMPAQ) – for local & remote workstation
FCC ID: N/A
Model No.: S510
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0025
Data Cable: Shielded, 1.7m
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 3. -- PS/2 Keyboard (COMPAQ)– for local & remote workstation
FCC ID: N/A
Model No.: 6511-VA
Serial No.: SP0038
Data Cable: Shielded, 1.7m
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 4. -- PS/2 Mouse (COMPAQ)– for local & remote workstation
FCC ID: JNZ211443
Model No.: M-S69
Serial No.: SP0047
Data Cable: Non-Shielded, 1.8m
Support Unit 5. -- Printer (HP) – for local workstation
FCC ID: B94C2642X
Model No.: DJ 400
Power Supply Type: Linear
Power Cord: Non-Shielded
Serial No.: SP0057
Data Cable: Shielded, 360 degree via metal backshells, 1.35m
Support Unit 6. -- Modem (ACEEX)– for local workstation
FCC ID: IFAXDM1414
Model No.: DM1414
Power Supply Type: Linear
Power Cord: Non-Shielded
Serial No.: SP0063
Data Cable: Shielded, 360 degree via metal backshells, 1.15m
Support Unit 7. -- Personal Computer (COMPAQ)– for remote workstation
FCC ID: N/A
Model No.: Evo D380mx
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0018
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
< EMS >
Support Unit 1. -- Personal Computer (DELL)– for local workstation
FCC ID: N/A
Model No.: DHM
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0015
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 2. -- Monitor (VIEWSONIC) – for local workstation
FCC ID: N/A
Model No.: VCDTS21914-3P
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0027
Data Cable: Shielded, 1.7m
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 3. -- PS/2 Keyboard (HP)– for local workstation
FCC ID: N/A
Model No.: KB-0316
Serial No.: SP0032
Data Cable: Shielded, 1.9m
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
Support Unit 4. -- PS/2 Mouse (HP)– for local workstation
FCC ID: N/A
Model No.: M-S69
Serial No.: SP0044
Data Cable: Shielded, 1.8m
Support Unit 5. -- Notebook (DELL)– for remote workstation
FCC ID: N/A
Model No.: D400
Power Supply Type: Switching
Power Cord: Non-Shielded
Serial No.: SP0083
Remark: This support device was tested to comply with FCC standards and authorized under a declaration of conformity.
3.Test Software
< EMI >
An executive program, EMITEST.EXE under WIN XP, which generates a complete line of continuously repeating “ H “ pattern was used as the test software.
The program was executed as follows :
- Turn on the power of all equipment.
- The PC reads the test program from the hard disk drive and runs it.
- The PC sends " H" messages to the monitor, and the monitor displays " H" patterns on the screen.
- The PC sends “ H “ messages to the printer, then the printer prints them on the paper.
- The PC sends “ H “ messages to the modem.
- The PC sends " H" messages to the internal hard disk, and the Hard Disk reads and writes the message.
- Repeat the steps from c to f.
At the same time, “ Ping ” was executed to link with the remote workstation to receive and transmit data by STP cable.
< EMS >
During the test, the“Network Neighborhood” under WIN XP was executed to link with the remote workstation to receive and transmit data by STP cable.
4.General Information of Test
4.1.Test Facility
<EMI>
Test Site Location:No. 30-2, Lin 6, Diing-Fwu Tsuen, Lin-Kou-Hsiang,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2601-1640
FAX : 886-2-2601-1695
Test Site No.: CO01-LK, OS04-LK
<EMS>
Test Site Location:No. 52, Hwa Ya 1St Road, Hwa Ya Technology Park,
Kwei-Shan Hsiang, TaoYuan Hsien, Taiwan, R.O.C.
TEL : 886-3-327-3456
FAX : 886-3-318-0055
4.2.Test Voltage
230V / 50Hz
5.Test of Conducted Powerline
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads of the EUT according to the methods defined in European Standard EN 55022 Clause 9. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown below. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions.
5.1.Typical Test Setup Layout of Conducted Powerline
5.2.Typical Test Setup Layout of disturbances at telecommunication ports
5.3.Test Procedure
- The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface.
- Connect EUT to the power mains through a line impedance stabilization network (LISN).
- Connect Telecommunication port to ISN (Impedance Stabilization Network).
- All the support units are connect to the other LISN.
- The LISN provides 50 ohm coupling impedance for the measuring instrument.
- The CISPR states that a 50 ohm , 50 microhenry LISN should be used.
- Both sides of AC line were checked for maximum conducted interference.
- The frequency range from 150 kHz to 30 MHz was searched.
- Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
5.4.Test Result of AC Powerline Conducted Emission
Frequency Range of Test : from 150 kHz to 30 MHz
Temperature : 24 C
Relative Humidity : 51 %
Test Mode : Adapter: DV-1280-3SAA
Corrected Reading (dBuV) = LISN Factor + Cable Loss + Read Level = Level
■The test was passed at the minimum margin that marked by a frame in the following data
Test Engineer :
Josh Lin
5.5.Test Result of Disturbances at Telecommunication Ports
Frequency Range of Test : from 150 kHz to 30 MHz
Temperature : 24 C
Relative Humidity : 51 %
Test Mode : LAN: 100Mbps
Corrected Reading (dBuV) = LISN Factor + Cable Loss + Read Level = Level
■The test was passed at the minimum margin that marked by a frame in the following data
Test Engineer :
Josh Lin
6.Test of Radiated Emission
Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz according to the methods defines in European Standard EN 55022, Clause 10. The EUT was placed on a nonmetallic stand, 0.8 meter above the ground plane, as shown below. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions.
6.1.Test Procedure
- The EUT was placed on a rotatable table top 0.8 meter above ground.
- The EUT was set 10 meters from the interference-receiving antenna which was mounted on the top of a variable height antenna tower.
- The table was rotated 360 degrees to determine the position of the highest radiation.
- The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement.
- For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading.
- Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode.
- If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method and reported.
6.2.Test Result of Radiated Emission
Temperature : 24 C
Relative Humidity : 62 %
Test Mode : Adapter: DV-1280-3UP
Corrected Reading : Antenna Factor + Cable Loss + Read Level Preamp Factor = Level
■The test was passed at the minimum margin that marked by the frame in the following test record
Test Engineer :
Benny Lee
7.Harmonics Test
As specified on clause 7 and figure Z1of EN 61000-3-2:2000, the limits are not specified for equipment with a rated power of 75W or less.
The EUT meets the above condition, soit conforms to EN 61000-3-2.
8.Voltage Fluctuations Test
8.1.Standard
FINAL TEST RESULT: PASS
Standard : EN 61000-3-3:1995/A1:2001
Temperature: 24 °C
Relative Humidity: 48 %
Test Mode:Adapter: DV-1280-3UP
Test Date: Dec. 01, 2005
8.2.Test Procedure
According to EN 61000-3-2
8.3.Test Setup
8.4.Test Record
Urms = 228.7VFreq = 49.987Range: 0.25 A
Irms = 0.036AIpk = 0.070Acf = 1.949
P = 5.227WPap = 8.265VApf = 0.633
Test - Time :1 x 10min = 10min( 100 %)
LIN (Line Impedance Network) :SLIN 0.24ohm +j0.15ohm N:0.16ohm +j0.10ohm
Limits :Plt :0.65Pst :1.00
dmax :4.00 %dc :3.30 %
dtLim:3.30 %dt>Lim:500ms
Test completed, Result: PASSED
Plt = 0.072
PstP50sP10sP3sP1sP0.1sdmaxdcdt>Lim
[%][%][ms]
10.0720.0100.0100.0100.0100.0100.0000.0000.000
9.Electrostatic Discharge Immunity Test (ESD)
FINAL TEST RESULT:PASS
Pass Performance Criteria:B
Required Performance Criteria:B
Basic Standard:IEC 61000-4-2:1995/A2:2000
Product Standard:EN 55024:1998/A1:2001/A2:2003
Level :3 for air discharge
:2 for contact discharge
Test Voltage:2 / 4 / 8 kV for air discharge
:2 / 4 kV for contact discharge
Temperature:22 °C
Relative Humidity:42 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:During the test, the EUT was interfered.After the test, the
equipment continued to operate as intended without operator
intervention.
9.1.Test Setup
9.2.Test Procedure
Accorded to IEC 61000-4-2
9.3.Test Record
Test Point / Air Discharge / Contact DischargeHCP / N/A / BY 25
VCP / N/A / BY 25
Screw / N/A / BY 25
RJ45 Port / N/A / BY 25
Case / BY 10 / N/A
LED / BY 10 / N/A
DC Input Jack / BY 10 / N/A
10.Radio Frequency Electromagnetic Field Immunity Test (RS)
FINAL TEST RESULT:PASS
Pass Performance Criteria:A
Required Performance Criteria:A
Basic Standard:IEC 61000-4-3:2002
Product Standard:EN 55024:1998/A1:2001/A2:2003
Level :2
Frequency Range:80-1000 MHz
Field Strength:3 V/m (Modulated 80% AM at 1kHz)
Temperature:25 °C
Relative Humidity:50 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:Normal
10.1.Test Setup
NOTE : The SPORTON 7m x 4m x 4m semichoic chamber is compliance with the sixteen points uniform field requirement as stated in IEC 61000-4-3 Section 6.2.
10.2.Test Procedure
Accorded to IEC 61000-4-3
11.Electrical Fast Transient/Burst Immunity Test (EFT/BURST)
FINAL TEST RESULT:PASS
Pass Performance Criteria:B
Required Performance Criteria:B
Basic Standard:IEC 61000-4-4:1995/A2:2001
Product Standard:EN 55024:1998/A1:2001/A2:2003
Level : on Power Supply -- 2
: on I/O signal, data and control line -- 2
Test Voltage : on Power Supply -- 0.5/1.0 kV
: on I/O signal, data and control line -- 0.25/0.5 kV
Temperature:24 °C
Relative Humidity:50 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:During the test, the EUT was interfered.After the test, the
equipment continued to operate as intended without operator
intervention.
11.1.Test Setup
11.2.Test Procedure
Accorded to IEC 61000-4-4
12.Surge Immunity Test
FINAL TEST RESULT:PASS
Pass Performance Criteria:A
Required Performance Criteria:B
Basic Standard:IEC 61000-4-5:1995/A1:2000
Product Standard:EN 55024:1998/A1:2001/A2:2003
Surge Wave Form (Tr/Th):1, 2/50(8/20)μs
Level :2
Test Voltage:0.5 / 1.0 kV
Temperature:25 °C
Relative Humidity:50 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:Normal
Remark: The test on RJ45 ports is not required due to the normal
Functioningcannot be achieved because of the impact of the
CDN on theEUT.
12.1.Test Procedure
Accorded to IEC 61000-4-5
12.2.Test Record
Voltage ( kV ) / Test Location / Polarity / Phase Angle / TestResult
0 / 90 / 180 / 270
1 kV / L - N / + / A / A / A / A / PASS
- / A / A / A / A / PASS
2 kV / L - PE / + / A / A / A / A / PASS
- / A / A / A / A / PASS
N - PE / + / A / A / A / A / PASS
- / A / A / A / A / PASS
Remark : PE = Earth reference
13.Conducted Disturbances Induced by Radio-Frequency Field Immunity Test ( CS )
FINAL TEST RESULT:PASS
Pass Performance Criteria:A
Required Performance Criteria:A
Basic Standard:IEC 61000-4-6:1996/A1:2000
Product Standard:EN 55024:1998/A1:2001/A2:2003
Level :2
Test Voltage:3 V/rms ( Modulated, 1kHz, 80%, AM )
Frequency Range:0.15 MHz to 80 MHz
Dwell Time:2.9 seconds
Frequency Step Size:1 %
Coupling Mode : CDN-M16 SW M2 for AC power ports,
CDN-RJ45/S for Telecom Ports
Temperature:24 °C
Relative Humidity:50 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:Normal
13.1.Test Procedure
Accorded to IEC 61000-4-6
13.2.Test Setup
14.Power Frequency Magnetic Field Immunity Tests
FINAL TEST RESULT:PASS
Pass Performance Criteria:A
Required Performance Criteria:A
Basic Standard:IEC 61000-4-8:1993/A1:2000
Product Standard:EN 55024:1998/A1:2001/A2:2003
Temperature:24 °C
Relative Humidity:48 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:Normal
14.1.Test Record
Power Frequency Magnetic Field / Testing duration / Coil Orientation / Results / Remark50Hz, 1A/m / 1.0 Min / X-axis / Pass / Normal
50Hz, 1A/m / 1.0 Min / Y-axis / Pass / Normal
50Hz, 1A/m / 1.0 Min / Z-axis / Pass / Normal
14.2.Test Procedure
Accorded to IEC 61000-4-8
14.3.Test Setup
GRP : / Ground plane / C1 : / Power supply circuitA : / Safety earth / C2 : / Signal circuit
S : / Insulating support / L : / Communication line
EUT : / Equipment under test / B : / To power supply source
Lc : / Induction coil / D : / To signal source, simulator
E : / Earth terminal / G : / To the test generator
15.Voltage Dips and Voltage Interruption Immunity Tests
FINAL TEST RESULT:PASS
Pass Performance Criteria:C for voltage interruption, A for voltage dips
Required Performance Criteria:C for voltage interruption, B/C for voltage dips
Basic Standard:IEC 61000-4-11:1994/A1:2000
Product Standard:EN 55024:1998/A1:2001/A2:2003
Temperature:24 °C
Relative Humidity:49 %
Atmospheric Pressure:100.0 kPa
Test Date:Dec. 01, 2005
Observation:Normal
15.1.Test Record of Voltage Interruption
Voltage / Phase Angle / % Reduction / Duration / Observation( V ) / 0 / 180 / (periods)
230 / C / C / >95% / 250 / After the interruption, the power of EUT reset automatically.
15.2.Test Record of Voltage Dips
Voltage / Phase Angle / % Reduction / Duration / Observation( V ) / 0 / 180 / (periods)
230 / A / A / 30 / 25 / Normal
230 / A / A / >95 % / 0.5 / Normal
15.3.Test Procedure
Accorded to IEC 61000-4-11
16.List of Test Instrument
< EMI >
Instrument / Manufacturer / Model No. / Serial No. / Characteristics / Calibration Date / RemarkReceiver / R&S / ESCS 30 / 8368581024 / 9 kHz - 2.75GHz / Jul. 20, 2005 / Conduction
(CO01-LK)
LISN / Rolf Hoine / NNB-2/16Z / 98087 / 9 kHz-30MHz / Sep. 12, 2005 / Conduction
(CO01-LK)
LISN / Rolf Hoine / NNB-2/16Z / 98009 / 9 kHz-30MHz / Sep. 21, 2005 / Conduction
(CO01-LK)
RF Cable-CON / Suhner Switzerland / RG223/U / CB017 / 9 kHz-30MHz / Dec. 17, 2004 / Conduction
(CO01-LK)
CURRENT PROBE / SCHAFFNER / SMZ11 / 18029 / 9 kHz - 30MHz / May 30, 2005 / Conduction
(Telecommunication port )
Open AreaTest Site / SPORTON / OATS-10 / OS04-LK / 30 MHz- 1 GHz
10m, 3m / Aug. 06, 2005 / Radiation
(OS04-LK)
Amplifier / HP / 87405A / 3207A01437 / 10 MHz - 3 GHz / Sep. 14, 2005 / Radiation
(OS04-LK)
SpectrumAnalyzer / HP / 8560E / 3728A03186 / 9 kHz -1.8 GHz / Dec. 29, 2004 / Radiation
(OS04-LK)
Receiver / R&S / ESCS30 / 100359 / 9 kHz- 2.75GHz / Aug. 11, 2005 / Radiation
(OS04-LK)
Bilog Antenna / CHASE / CBL6112B / 2288 / 30MHz- 2GHz / Jun. 08, 2005 / Radiation
(OS04-LK)
Turn Table / EMCO / 2080 / 9711-2021 / 0- 360 degree / N/A / Radiation
(OS04-LK)
Antenna Mast / EMCO / 2075 / 9711-2115 / 1 m- 4 m / N/A / Radiation
(OS04-LK)
RF Cable-R10m / BELDEN / RG8/U / CB011 / 30 MHz- 1 GHz / Jan. 08, 2005 / Radiation
(OS04-LK)
RF Cable-R03m / BELDEN / RG8/U / CB012 / 30 MHz- 1 GHz / Jan. 08, 2005 / Radiation
(OS04-LK)
※Calibration Interval of instruments listed above is one year.
< EMS>
Instrument / Manufacturer / Model No. / Serial No. / Characteristics / Calibration Date / RemarkESD Simulator / SCHAFFNER / NSG 435 / 5537 / Air: 0 kV - 16.5 kV
Contact: 0 kV - 8 kV / Feb. 23. 2005 / ESD
Antenna / FRANKONIA / BTA-L / 02002L / 26 MHz - 1 GHz / Jan. 05, 2005 / RS
Field Strength Monitoring Antennas (Probe) / AR / FP3000A / 16077 / 0.1 MHz - 1 GHz / Aug. 26, 2005 / RS
RS immunity Test system / HP / EMS test System / 2062 / 80 MHz - 1 GHz
3V/m
10v/m / Nov. 23, 2005 / RS
Amplifier / AR / 100W 1000M3 / 16060 / 80 MHz - 1 GHz / Nov. 23, 2005 / RS
Power Meter / EMC Automation / 438A / 3513U04050 / 100 kHz -4.2 GHz / Nov. 23, 2005 / RS
Signal Generator / HP / 8648A / 3426A00771 / 100 kHz - 1 GHz / Nov. 23, 2005 / RS
Power Sensor / HP / 8481D / 3318A13140 / 100 kHz - 1 GHz / Nov. 23, 2005 / RS
Power Sensor / HP / 8482A / 3318A26464 / 100 kHz - 1 GHz / Nov. 23, 2005 / RS
Attenuator / HP / 8491A / 53603 / 100 kHz - 1 GHz / Nov. 23, 2005 / RS
EFT Generator / EMC -PARTNER / TRANSIENT -2000 / TRA2000-376 / 0 kV - 4.4kV / Jul. 04, 2005 / EFT
EFT/Clamp / EMC -PARTNER / CH4242 / CNEFT1000
-200 / 0 kV - 1kV / N/A / EFT
SURGE Generator / EMC -PARTNER / TRANSIENT -2000 / TRA2000-376 / 0 kV - 6kV/2Ω
0 kV - 500 kV/12Ω / Jul. 04, 2005 / SURGE
SURGE/CDN / EMC -PARTNER / DN-T1+CN-T1 / CDNKIT1000T-22 / 0.5 kV - 2 kV / N/A / SURGE
Conducted Immunity
Test System / FRANKONIA / CIT-10/75 / 1999010443 / 100 kHz - 266 MHz / Apr. 06, 2005 / CS
Conducted Immunity
Test System
Amplifier / A.R / 75A220 / 16980 / 15 - 230 MHz
FM 1 kHz 80﹪
75W / Apr. 26, 2005 / CS
Coupling and Decoupling Network / SCHAFFNER / CDN M016 / 16672 / 150 kHz - 230 MHz / Apr. 12, 2005 / CS
Coupling and Decoupling
Network / FRANKONIA / CDN RJ45/S / A3018004 / 150 kHz - 230 MHz / Apr. 12, 2005 / CS
Instrument / Manufacturer / Model No. / Serial No. / Characteristics / Calibration Date / Remark
Magnetic field Immunity Loop / FCC
(KEYTEK) / F-1000-4-8/9/10-L-1AM / 03004 / 30A//CONTINUOUS
100A/2Hrs
230A/30SEC / Mar.18, 2005 / PFMF
Magnetic
Generator / FCC
(KEYTEK) / F-1000-4-8/G--125A / 9830 / 30A//CONTINUOUS
100A/2Hrs
230A/30SEC / Mar.18, 2005 / PFMF
DIP Generator / EMC -PARTNER / TRANSIENT -2000 / TRA2000-376 / 230VA/50Hz/60Hz
0%Open/5S
0%Short/5S
40%0.10S
70%/0.01S / Jul. 04, 2005 / DIP
Harmonic/Flicker
Test System / EMC PARTNER / Harmonics -1000 / HAR1000-41 / 4000VA
16A PEAK / Nov. 22, 2005 / Harmonics,
Flicker
※Calibration Interval of instruments listed above is one year.