Relays.

CURRENT BALANCE RELAY:

Range of setting75 +/- 45 o Amps

Operating Time1.6 milli sec

CURRENT BALANCE AUXILLIARY RELAY:

Elec Spec853211

Resistance at 20 o C775 Ohms

Contract Pressure250 +/- 50 gms

Over stroke2 mm

Single element overload relay Type M5021STR20B2 for compressor and Type M5021STR19B2 for Motor Generator

TRIP COIL:

Elec Spec850018

Resistance at 20 o C0.0422 Ohm

HOLD COIL:

Elec Spec851015

Resistance at 20 o C299 Ohm

RESET COIL:

Elec Spec851023

Resistance at 20 o C193 Ohms

Calibration14-18-22 amps

Set at22 amps

TEST:

  1. With 25 volt across the hold coil and 32.5 amps passing through the trip coil, the overload element must not trip.
  2. Reverse Polarity of the hold coil and (repeat 1.)

MOTOR GENERATOR

TRIP COIL:

Elec Spec850018

Resistance at 20 o C0.0422 Ohm

HOLD COIL:

Elec Spec851015

Resistance at 20 o C2990 Ohm

RESET COIL:

Elec Spec851023

Resistance at 20 o C193 Ohm

Calibration18-32-46 amps

Set at46 amps

TEST:

  1. With 25 volt across the hold coil and 65 amps passing through the overload trip coil, the overload element must not trip
  2. Reverse polarity of the hold coil and (repeat 1.)

H.T INDICATING RELAY TYPE RL 641 A – F 12 M:

Contact type3 +/- 1 mm

WipeAbout 1 mm

Overstroke2 mm

Elec spec853222

Elec Spec851023

Resistance at 20 o C2299 Ohm

TRIP COIL:

½ turn of 10 mm x 20 mm

Reset coil

Elec spec851023

Resistance at 20 o C193 Ohm

Calibration700-900-1100 amps

Set at900 amps

TEST:

1.Relay should reset with 55 volt on the reset coil

CURENT LIMIT RELAY TYPE RL 320A – CB – M

Contact Wipe0.5 mm (approximately)

Contact Gap3 +/- 1 mm

Contact Over travel2 mm

Contact pressure50 +/- 10 gms

SHUNT COILS:

Elec Spec853212

Resistance at 20 o CWinding c-d 247 Ohms

Winding a-b 237 Ohms

ADJUSTMENT:

  1. With the series coils only in circuit the calibration spring should adjusted so that the moving contacts touch the fixed contact Fingers at 365 amps, passing through the series coils.
  2. With 110 V DC applied to the shunt coil, circuit between wires 301 & 311 (positive to 301) the resistor between wires 302 & 311 should be adjusted until the moving contact touch the fixed contact fingers at 490 amps, passing through the series coils.
  3. With 110 V DC applied to shunt coils circuits between wires 301 & TC6 (positive to 301), the resistor between wires 311 & T6 should be adjusted unit; the moving contact touch the Fixed contact fingers at 480 amps, passing through the series coils.

No current relay Type 28EB

SERIES COIL – 6 TURNS OF 8 MM X 32 MM COPPER STRAP:

PICKUP COIL:

Elec Spec853013

Resistance at 20 o C449 Ohm

Dropout current (series coil)5 amps

TIME DELAY RELAY TYPE 28ER8:

Elec Spec800242

Resistance at 20 o C364 Ohm

Time delay1.5 to 3.5 seconds

EMERGENCY LIGHTS RELAY TYPE M18ER5:

OPERATING COIL:

Elec Spec851131

Resistance at 20 o C957 Ohm

L.T. INDICATION RELAY/ INCREASE ACCELERATION RELAY:

RELAY TYPE RL 789A-110

Contact gap2 to 2.5 mm

Contact pressure30 +/- 10 gms

OverstrokeAbout 2 mm

Elec Spec853219

Resistance at 20 o C1030 Ohm

MAGNETIC COIL (UPPER):

Elec Spec853217

Resistance at 20 o C230 Ohm

MAGNETIC COIL (LOWER):

Elec Spec853216

Resistance at 20 o C118 Ohm

Contact gap2.5 +/- 0.5 mm

Contact pressure200 +/- 50 gms

OVER VOLTAGE RELAY TYPE RL424A1-M:

TRIP COIL (UPPER)

Elec Spec853218

Resistance at 20 o C88 Ohm

Pick up voltage of Trip Coil120 to 125 volts

(With the resistor in series with the trip coil)

MAGNETIC COIL (LOWER):

Elec Spec8532216

Resistance at 20 o C118 Ohm

Contact gap2.5 +/- 0.5 mm

Contact pressure200 +/- 50 gms

MASTER CONTROLLER TYPE M26MC7:

Contact gap2.54 to 3.2 mm

Finger pressure280 to 400 gms

(Measured at the contact with finger closed)

CONTROL CUTOUT SWITCH TYPE M14MS10A1:

Contact gap3.2 mm

Contact pressure170 gms/min

Cam to roller gap0.8 mm

(When fingers are making contact)

PANTOGRAPH OPERATING VALVE TYPE M5015PV2:

OPERATING COIL:

Elec Spec853007

Resistance at 20 o C29.9 Ohm

Double pole latched contactor type M8EC4-lights

OPERATING COIL:

Elec Spec851019

Resistance at 20 o C102 Ohm

TRIP COIL:

Elec Spec851016

Resistance at 20 o C105 Ohm

Right hand blow out coil (Main lights)

Four turns of 3.048 x 15.9 mm copper strap

LEFT HAND BLOW OUT COIL (EMERGENCY LIGHTS):

Elec Spec850004

Resistance at 20 o C0.0122 Ohm

Minimum pick up65 volts

Contact pressure0.9 to 1.8 kg

Double pole latched contactor type M8EC5-fans

OPERATING COIL:

Elec Spec851019

Resistance at 20 o C102 Ohm

TRIP COIL:

Elec Spec851016

Resistance at 20 o C105 Ohm

BLOW OUT COILS:

Elec Spec850004

Resistance at 20 o C0.0122 Ohm

Minimum pick up65 volts

Contact pressure0.9 to 1.8 kg

E.M. CONTACTOR FOR AUXILLIARY COMPRESSOR:

BLOW OUT COIL:

Elec Spec850134

Resistance at 20 o C0.01648 Ohm

OPERATING COIL:

Elec Spec851107

Resistance at 20 o C1122 Ohm

R.R. RESISTOR:

Main ResistorWeak Field Resistor

SectionCold Ohm at 20 o CSectionCold Ohm at 20 o C

M16 – M17 2.24M.G. Protective9.7

M12 – M130.418Resistor MG 3 -

M13 – M140.335MG4

M14 – M150.280Compressor19.4

M15 – M160.234Protective

M17 – M180.202Resistor C4 – M32

M19 – M210.418

M21 – M220.335

M22 – M230.280

M23 – M240.234

Battery charging resistor:

0.415 Ohm set at 0.3 Ohm