Condenser Coils for Carrier Thinline Units

Condenser Coils for Carrier Thinline Units

19 May 2019

Ref: CAR0004

Condenser Coils for Carrier ThinLINE units.

Please ensure all engineering staff are made aware of the following.

Carrier has announced that as a result of their ongoing research to improve the long term reliability of their ThinLINE units, the following up-grade should be carried out on all Condenser coils fitted to our ThinLINE units, (those Carrier units fitted with reciprocating compressors).

By removing the top left hand mounting bolt on the condenser coil, as detailed in the attached Carrier bulletin, will enhance the life of the condenser coil. Please can you ensure this modification is carried out on all our ThinLINE units during PTI/repair. This can be claimed in Merc+ under STS code 5430, and allows 0.1 hr in modes 41 & 43.

When fitting a new condenser coil to a ThinLINE unit, this bolt should not be installed. New condenser coils being supplied as replacement by Carrier may not have the bolt hole; therefore no action needs to be taken.

This modification covers replacement part numbers 81-01575-00SV and 69NT43-202-20.

Please also be advised that part number 81-01575-00SV has now been superseded by 81-04046-00SV. Merc+ has been up-dated accordingly. Please continue to use up your stocks of 81-01575-00SV, however you will need to use part number 81-04046-00SV for in-put in to Merc+.

Please do not hesitate to contact us should you have any questions with regards to the above.

Carrier Bulletin:

Container Products

CTR-SER10-005 08-23-10

Subject: ThinLINE® Condenser Coil

As a result of ongoing research to improve the long term reliability of the ThinLINE unit, Carrier Transicold has identified and implemented a design enhancement on new unit production. This enhancement involves the elimination of a bolt from the back wall left header side of the condenser coil, effective with s/n MSU 60321497(Feb 2010) production.

This design enhancement can also be implemented on ThinLINE units that were manufactured between 2003 and 2009. For equipment owners & operators interested in making the upgrade, it can be easily accomplished during the units Pre-Trip or regular maintenance interval by simply removing the top bolt from the back wall left side of the condenser coil and caulking the hole, as shown in the photos below.

3 row / 7 mm condenser coil (part number 81-01575-00)

If a replacement coil is fitted into the unit then this bolt should be left off. PPG 7mm replacement coils will not have the bolt hole.

This enhancement does not affect EliteLINE®, StreamLINE® or PrimeLINE® products.