REACH Zinc Consortium

Common elements for drafting e-SDS related to zinc and inorganic zinc substances

Draft

Substance: Zinc Oxide Standard Grade

Remark:

This document is related to zinc oxide standard grade, which is the most common grade on the market. This standard grade contains typically Pb < 30ppm.

There can also be lower grade zinc oxide on the market, containing, notably up to 1.5% of Pb. To avoid confusion, elements related to these low grades are not presented in this document. For further information on these low grades, the reader is referred to the IUCLID and CSR files.

1.1. Product identifier

Product name: Zinc oxide

Product code:

Common / Trade name:

Other:

1.2. Relevant uses and uses advised against

·  Colouring agents, pigments

·  Food/feedstuff additives

·  Fuels and fuel additives

·  Intermediates

·  Laboratory chemicals

·  Lubricants and lubricant additives

·  Plating agents and metal surface treating agents

·  Process regulators, other than polymerisation or vulcanisation processes

·  component in batteries

·  Corrosion inhibitors and anti-scaling agents

·  Fertilisers

·  Pharmaceutical substance

·  Photosensitive agents and other photo-chemicals

·  Process regulators, used in vulcanisation or polymerisation processes

·  Processing aid, not otherwise listed

·  Semiconductors

A complete list of uses for which a Generic Exposure Scenario (GES) is provided in the annex introduction

ð  No uses advised against

1.3. Details on the supplier of the SDS

1.4. Emergency telephone number: (EM): give the number of the company (+ working hours) and emergency number in the country of destination.

Section 2: Hazard identification

2.1. Classification of the substance

2.1.1. Classification according to Regulation (EC) No 1272/2008 (CLP/GHS)

Aquatic Acute 1: H400 Very toxic to aquatic life, M factor 1

Aquatic Chronic 1: H410 Very toxic to aquatic life with long lasting effects, M factor 1

2.1.2. Classification according to Directive 67/548/EEC (DSD):

ð  N; R50-53

2.2. Labelling

2.2.1. Labelling according to Regulation (EC) No 1272/2008 (CLP/GHS)

Hazard pictogram:

GHS09: environment

Signal word:

Warning

Hazard statements:

H410: Very toxic to aquatic life with long lasting effects.

Precautionary statements:

·  P273: Avoid release to the environment.

·  P391: Collect spillage.

·  P501: Dispose of contents/container to...

·  to be further specified by companies; (guidance: give not more than 6)

2.2.2. Labeling according to Directive 67/548/EEC (DSD):

Hazard statements:

R-phrases:

R50/53 - very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment

Precautionary statements:

S-phrases:

·  S60 - this material and its container must be disposed of as hazardous waste

·  S61 - avoid release to the environment. refer to special instructions/safety data sheets

2.3. Other hazards

Substance meets the criteria for PBT according to Regulation (EC) 1907/2006, Annex XIII

ð  No

Substance meets the criteria for vPvB according to Regulation (EC) No. 1907/2006, Annex XIII:

ð  No

Section 3: Composition/Information on ingredients

Name: zinc oxide standard

Description: typical grade with low level impurities

Note: the information below is given to define the substance in the CSR. It can be adapted to company-specific information, if appropriate.

Degree of purity: > 80.0 — < 100.0 % (w/w)

Constituents

Constituent / Typical concentration / Concentration range / Remarks
zinc oxide
EC no: 215-222-5 / ca. 99.8 % (w/w) / > 80.0 — < 100.0 % (w/w)

Impurities

Impurity / Typical concentration / Concentration range / Remarks
zinc carbonate
EC no.: 222-477-6 / < 0.1 % (w/w) / >= 0.0 — < 3.0 % (w/w)

Section 4: First Aid Measures

4.1. Description of first aid measures

REACH Annex II: This section of the safety data sheet shall describe the initial care in such a way that it can be understood and given by an untrained responder without the use of sophisticated equipment and without the availability of a wide selection of medications. If medical attention is required, the instructions shall state this, including its urgency.

Note: In addition to the information contained in the old MSDS format, sections 4.2 and 4.3 are now required. Information is to be specified by companies on the basis of their former SDS and ECHA guidance.

4.2. Most important symptoms and effects, both acute and delayed

4.3. Indication of any immediate medical attention and special treatment needed

Section 5: fire fighting measures

REACH Annex II: This section of the safety data sheet shall describe the requirements for fighting a fire caused by the substance or mixture, or arising in its vicinity

Section 6: accidental release measures:

REACH Annex II: This section of the safety data sheet shall recommend the appropriate response to spills, leaks, or releases, to prevent or minimise the adverse effects on persons, property and the environment. It shall distinguish between responses to large and small spills, in cases where the spill volume has a significant impact on the hazard. If the procedures for containment and recovery indicate that different practices are required, these shall be indicated in the safety data sheet

EM: the text in Section 6 can be copied from IUCLID Section 11, so as to encourage members to be consistent.

Information is to be specified by companies on the basis of their former SDS and ECHA guidance.

Section 7: Handling and storage

REACh Annex II: This section of the safety data sheet shall provide advice on safe handling practices. It shall emphasise precautions that are appropriate to the identified uses referred to under subsection 1.2 and to the unique properties of the substance or mixture.

Information in this section of the safety data sheet shall relate to the protection of human health, safety and the environment. It shall assist the employer in devising suitable working procedures and organisational measures according to Article 5 of Directive 98/24/EC and Article 5 of Directive 2004/37/EC of the European Parliament and of the Council.

Where a chemical safety report is required, the information in this section of the safety data sheet shall be consistent with the information given for the identified uses in the chemical safety report and the exposure scenarios showing control of risk from the chemical safety report set out in the annex to the safety data sheet.

Section 8: Exposure Controls/Personal Protection

REACH Annex II: This section of the safety data sheet shall describe the applicable occupational exposure limits and necessary risk management measures.

Where a chemical safety report is required, the information in this section of the safety data sheet shall be consistent with the information given for the identified uses in the chemical safety report and the exposure scenarios showing control of risk from the chemical safety report set out in the annex to the safety data sheet.

Note: a list of existing national OELs in different countries is given below, cf. CSR. These OELs are largely corresponding to the DNELs derived under REACH. For member states where no OEL is available, reference can be made to these DNELs. It is emphasised that different OELs (and DNELs) are to be applied for readily soluble zinc substances and slightly soluble (including insoluble) substances on resp.

OELs for ZnCl2 – group: soluble zinc compounds

(e.g.: ZnCl2 - ZnSO4 - Zn(H3PO4)2 - ZnCl2/2NH4Cl - ZnCl2/3NH4Cl)

Country/organisation / 8 hour-TWA
mg/m3 / 15 min-STEL
mg/m3 / References
USA / 1 / 2 / ACGIH (1991)
The Netherlands / 1 / SZW (1997)
UK / 1 / 2 a) / HSE (1998)
Sweden / 1b) / National Board of Occupational Safety and Health,
Sweden (1993)
Denmark / 0.5 / Arbejdstilsynet, 1992

a) This value is a 10 minutes-STEL

b) This TWA is determined for dust

OELs for ZnO – group: “slightly soluble / insoluble Zn compounds”

(e.g.: ZnO - Zn(OH)2 - Zn3(PO4)2 - ZnCO3 - Zn metal – ZnS)

Country/organisation / 8 hour-TWA
mg/m3 / 15 min-STEL
mg/m3 / References
USA / 5 (fumes)
10 (dust) / 10 (fumes)
(ceiling) / ACGIH (1991) (guidance values)
USA / 5 (fumes)
15 (dust; total)
5 (dust; respirable) / OSHA (1989) (legal limit values)
The Netherlands / 5 (fumes) / SZW (1997)
Germany / 5 (fumes)
6 (dust) / DFG (1997)
UK / 5 (fumes)
10 (dust) / HSE (1998)
Sweden / 5 (fumes) / National Board of Occupational Safety and Health,
Sweden (1993)
Denmark / 4 (fumes)
10 (dust) / Arbejdstilsynet (1992)

8.1.4 DNELs and PNECs

DNELs

·  Oral

o  DNELoral soluble Zn = 50 mg Zn/day (i.e., 0.83 mg Zn/kg bw/day);

o  DNELoral insoluble Zn = 50 mg Zn/day (i.e., 0.83 mg Zn/kg bw/day);

·  Dermal

o  DNELdermal soluble Zn = 500 mg Zn/day (i.e., 8.3 mg Zn/kg bw/day);

o  DNELdermal insoluble Zn = 5000 mg Zn/day (i.e., 83 mg Zn/kg bw/day);

·  Inhalation - Worker

o  DNELinhal soluble Zn (worker) = 1 mg Zn/m3;

o  DNELinhal insoluble Zn (worker) = 5 mg Zn/m3;

·  Inhalation - Consumer

o  DNELinhal soluble Zn (consumer) = 1.3 mg Zn/m3;

o  DNELinhal insoluble Zn (consumer) = 2.5 mg Zn/m3;

PNECs derived for the zinc ion

Compartment (Environment) / PNEC value for Zn ion
Freshwater / 20.6* µg/L
Saltwater / 6.1* µg/L
STP / 100 µg/L
Freshwater sediment / 117.8* mg/kg sediment d.w.
A generic bioavailability factor of 0.5 is applied by default: PNECbioav: 235.6 mg/kg sediment d.w.
Saltwater sediment / 56.5* mg/kg sediment d.w.
A generic bioavailability factor of 0.5 is applied by default: PNECbioav: 113 mg/kg sediment d.w.
Soil / 35.6* mg/kg soil d.w.
A generic bioavailability/ageing factor of 3 is applied by default: PNECbioav: 106.8 mg/kg soil d.w.
Oral / No potential for bioaccumulation

*added value

Calculation of local exposure- Bioavailability correction

The local exposure at a given site can be calculated specifically using the excel sheet prepared by Arche (see “DU scaling tool” on the “tools” page on http://www.reach-zinc.eu/)

In addition, bioavailability corrections can be integrated in the exposure assessment, if the environmental parameters that are needed for the calculations, are documented.

·  For water assessment, bioavailability model correction can be applied when the following water parameters are documented for the receiving water: Dissolved organic carbon (DOC), pH, hardness or Ca-concentration. For the calculations, the “zinc BLM-calculator” excel tool is used to this end (see “tools” on http://www.reach-zinc.eu/). When the local values of these parameters are unknown, regional data can be used as an alternative. Use of regional instead of local values should always be handled with caution.

·  For sediment, a generic bioavailability factor of 2 is already integrated in the PNEC, based on AVS/SEM levels and according to the risk assessment (ECB 2008). A further refinement of local bioavailability can be made when local AVS/SEM concentrations are documented. The bioavailable fraction of zinc is given by subtracting local AVS from local SEM-Zn (SEM-Zn - AVS).

·  For soil, a worst case bioavailability correction (corresponding to sandy soils) is already integrated. Further refinement for zinc bioavailability in other soil types is possible, when the local soil type is documented, together with pH, CEC (see “tools” on http://www.reach-zinc.eu/)

8.2 exposure controls:

Note: reference is made below to items of the GES. The companies can consider this information as complementary to the wording in existing MSDS. Information is to be specified by companies on the basis of their former SDS and ECHA guidance.

8.2.1. Appropriate engineering controls

Technical conditions and measures at process level (source) to prevent release

·  Process enclosures closed circuits or semi-enclosures where appropriate.

·  Local exhaust ventilation on furnaces and other work areas with potential dust and fumes generation, dust capturing and removal techniques (high efficiency 90-95%)

·  Containment of liquid volumes in sumps to collect/prevent accidental spillage

Technical conditions and measures to control dispersion from source towards the worker

·  Cyclones/filters (for minimizing dust emissions) : efficiency: 70-90% (cyclones), 50-80% (dust filters), 85-95% (double stage, cassette filters)

·  Dust control: ZnO dust needs to be measured in the workplace air (static or individual) according to national regulations.

·  Special care for the general establishment and maintenance of a clean working environment by e.g.:

·  Cleaning of process equipment and workshop

·  Storage of packaged Zn finished product in dedicated zones

Organisational measures to prevent /limit releases, dispersion and exposure

·  In general integrated management systems are implemented at the workplace e.g. ISO 9000/9001, ISO-ICS 13100, or alike, and are, when appropriate, IPPC-compliant.

Such management system would include general industrial hygiene practice e.g.:

o  information and training of personnel on prevention of exposure/accidents,

o  procedures for control of personal exposure (hygiene measures)

o  regular cleaning of equipment and floors, extended workers instruction-manuals

o  Procedures for process control and maintenance...

o  personal protection measures (see below)

8.2.2. Personal protection

The GES for ZnO production mentions the following in this respect:

·  Wearing of gloves and protective clothing is compulsory (efficiency >=90%).

·  With normal handling, no respiratory personal protection (breathing apparatus) is necessary. If risk for exceedance of OEL/DNEL, use e.g.:

o  -Dust filter-half mask P1 (efficiency 75%)

o  -Dust filter-half mask P2 (efficiency 90%)

o  -Dust filter-half mask P3 (efficiency 95%)

o  -dust filter-full mask P1 (efficiency 75%)

o  -dust filter-full mask P2 (efficiency 90 %)

o  -dust filter-full mask P3 (efficiency 97.5%)

·  Eyes: safety glasses are optional

·  Information-training of the workers and their staff and line managers focused on careful hygiene behaviour.

8.2.3. Environmental exposure control

Technical conditions and measures at process level (source) to prevent release

·  Process enclosures and closed circuits where relevant and possible.

·  Local exhaust ventilation on furnaces and other work areas with potential dust generation, dust capturing and removal techniques

·  Containment of liquid volumes in sumps to collect/prevent accidental spillage, acid solutions are treated with alkali. There is high temperature in the surroundings of the calcinations furnaces.

Technical onsite conditions and measures to reduce or limit discharges, air emissions and releases to soil