ASSEMBLY AND INSPECTION DATA SHEET

Title:
I&T ----- NCR 689 Disposition #5 Dated 10/12/2005 / Program:
/ Date:
10/10/2005 / AIDS NUMBER:
LAT-AIDS-01712
Drawing Number:
LAT-PS- 02563 / Drawing. Title:
Grid / Dwg. Rev.
- / Author:
B. Grist / Approval: Date
IFCT: L. Wai
R.E. B. Grist
Test Cond.: J. Canfield
Q.E. D. Bartholomew
Part Number
LAT-PS-02563 / S/N
Grid / Equipment Class:
Flight / Subsystem:
I&T / Charge No.
SEQ. / Description / Completed by: / Date / Q/A / Remarks

The purpose of this test sequence is the disposition on NCR 689 Disposition #5 dated 10/12/2005.

The test conductor may perform a power off at any time during this process to accommodate working requirements such as end of shift or end of test.

SEQ / Description / Completed / Date / Q/A / Remarks /
10  / Disposition #5 Step 1
- Remove cable saver (LAT-DS-05753 GLAT 2000) from the GASU end of Twr 9 JS1 TEM cable LAT-DS-02106. Record Flight demate in eLog.
- Perform continuity check on connector saver and re-validate using BOB and BOCs. Record open connections.
- If connector saver validates, the issue now resides in either the TEM cable or the TEM itself, stop and proceed to step Disposition #5 Step 2 (SEQ 20), else replace with new validated connector saver. Re-run EICIT on TEM/TEM Cable.
- Report finding to NCR 689 / Record cable saver S/N:
GLAT ______
20  / Disposition #5 Step 2
- Remove cable Tray and demate GASU to TEM cable from JS1,
- Perform visual inspection on the GASU to TEM cable and then attempt validation on BOB/BOC's using connector savers. Record Flight demate.
- If cable LAT-DS-2106 is validated, proceed to Disposition #5 Step 3 (SEQ 30), else make flight replacement of the LAT-DS-02106 cable. Record Flight mate in eLog. Re-run EICIT on TEM/TEM Cable, remate to GASU.
- Report finding to NCR 689 / Record cable S/N:
GLAT ______
30  / Disposition #5 Step 3
- Otherwise, perform visual inspection of TEM JS1 connector.
- Then perform an EICIT on JS1 of the TEM in TWR 9. There is a small caveat here, since there is no room to install a connector saver, the BOB to TEM mate will be made through a validated EGSE test cable. Inspect/clean EGSE cable prior to mate. Record Flight mate/demate to EGSE BOC's.
- Report finding to NCR 689
40  / QC Final / Close Aids.

AIDS NUMBER: LAT-AIDS-01712 Page 1 of 4