MANDATORYINSPECTIONS PermitNo._____
Town of Blind River, 11Hudson Street, Blind River ON, P0R 1B0, 705 356 2251
THEOWNERORHISAGENTISREQUIREDTO CALL, AT LEAST TWO (2) BUSINESSDAYSINADVANCE, TO SCHEDULE AN INSPECTIONOFTHEFOLLOWING:
PRE-CONSTRUCTION TO VERIFY BUILDINGLOCATION / PLUMBING ROUGH-IN(PRIORTOCOVERING) / OCCUPANCYCERTIFICATE
(PRIORTOOCCUPYINGTHEBUILDINGORPARTOFTHE BUILDING AFFECTECTED BY THE CONSTRUCTION)
FOOTINGFORMS(PRIORTOPLACINGCONCRETE)
/ STRUCTURALFRAMING(PRIORTOCOVERING) /REQUIREDFIREPROTECTION(IE:SMOKE)
FOUNDATIONWALLS(PRIORTOBACKFILL)
/INSULATION(PRIORTOCOVERING)
/FIREALARMVERIFICATIONCERTIFICATE
FOUNDATION DRAINAGE/WEEPING TITLES (PRIOR TO COVERING)
/VAPOUR/AIRBARRIER(PRIORTOCOVERING)
/ SPRINKLERSYSTEM TESTCERTIFICATEFOUNDATION INSULATION (PRIOR TO COVERING)
/HEATINGROUGHIN
/ WOOD BURNING APPLICATION/ CHIMNEY(VERIFICATION SHOWING APPLIANCE INSTALLED BY A WETT CERTIFIED PEROSN)
CONCRETESLAB (PRIORTOPLACINGCONCRETE) /FINAL(ATTHECOMPLETIONOF THECONSTRUCTION)
/DECK / PATIO / BALCONY
OTHER:______
FAILURE TO REQUEST MANDATORYINSPECTION WILL RESULT IN A DEFICIENTLY BEAING RECORDED AGAINT THE PROJECT AND WILL BE DISCLOSED TO ANY PERSON HAVING LEGAL RIGHT TO THE INFORMATION.
BUILDINGCODE ACT
13.-(1)Ordernotto Cover.An inspector maymakean order prohibiting the covering or enclosing of any part ofabuildingpendinginspection.
13.-(6)Orderto Uncover.A chiefbuilding official who has reason to believe that partof a buildingthat iscovered or enclosed hasnotbeenconstructed incompliancewiththisActor thebuildingcodemayorderthepersonsresponsiblefortheconstructionto uncoverthepartattheirownexpensefor the purpose ofaninspection if,
(a)thepartwas covered or enclosedcontrary toan order madeundersubsection (1);
(b)thenoticewas notgiveninthetimeprescribed by by-law orregulationmade underclause 7(e);
(c)a reasonabletime wasnot allowedafterthe notice was given foraninspectionto be carriedout; or
(d)theparthas beenconstructed without a permit being issued. 1993, c.23,s. 13.
As authorized by the Ontario Building Code Act. Section13(1) this will serve as an official "Order notto Cover".
Ordered by:______
John Jones, Chief Building Official
1.3.5Notices and Inspections
1.3.5.1Prescribed Notices
- ThisArticlesetsoutthenoticesthatarerequiredundersection10.2oftheAct.
- Thepersontowhomapermitundersection8oftheActisissuedshallnotifythechiefbuildingofficialor,wherearegisteredcodeagencyisappointedundertheActinrespectoftheconstructiontowhichthenoticerelates,theregisteredcodeagencyof,
a)readinesstoconstructfootings,
b)substantialcompletionoffootingsandfoundations priortocommencementofbackfilling,
c)substantialcompletionofstructuralframingandductworkandpipingforheatingandair-conditioningsystems,ifthebuildingiswithinthescopeofPart9ofDivision8,
d)substantialcompletionofstructuralframingandroughing-inofheating,ventilation,air-conditioningandair-contaminantextractionequipment,ifthebuildingisnotabuildingtowhichClause(c)applies,
e)substantialcompletionofinsulationandvapourbarriers,
f)substantialcompletion ofairbarriersystems,
g)substantialcompletionofallrequired)ireseparationsandclosuresandallfireprotectionsystemsincludingstandpipe,sprinkler,firealarmandemergency lightingsystems,
h)substantialcompletionoffireaccessroutes,
i)readinessforinspectionandtestingof,
- buildingsewersandbuildingdrains,
- fireservicemains,
- drainagesystemsandventingsystems,
- thewaterdistributionsystem,and
- plumbingfixturesandplumbingappliances,.
j)readinessforinspectionofsuctionandgravityoutlets,coversandsuctionpipingservingoutletsofanoutdoorpooldescribedinClause1.3.1.1.(l)(j)ofDivisionA,apublicpool orapublicspa,
k)substantial completion ofthe circulation I recirculation system ofanoutdoorpool described inClause 1.3.I.I.(I)(j)ofDivisionA,apublicpoolorpublicspaandsubstantialcompletionofthepoolbeforeitis firstfilledwithwater,
l)readinesstoconstructthesewagesystem,
m)substantialcompletionoftheinstallationofthesewagesystembeforethecommencementofbackfilling,
n)substantialcompletionofinstallationofplumbing notlocatedinastructure,beforethecommencementofbackfilling,
o)completionofconstructionandinstallationofcomponentsrequiredtopermittheissueofanoccupancype1mitunderSentence1.3.3.1.(3)ortopermitoccupancyunderSentencel.3.3.2.(1),ifthebuildingorpartofthebuildingtobeoccupiedisnotfullycompleted,and
p)completionofconstructionandinstallationofcomponentsrequiredtopermittheissueofanoccupancypermitunderSentence l.3.3.4.(4).
1.3.5.1Additional Notices
a)Aby-law,resolutionorregulationmadebyaprincipalauthorityunderclause7(l)(e)oftheActmayrequire!hatnoticeofoneormoreofthefollowingstagesofconstructionbegivenbythepersontowhomapermitisissuedundersection8oftheAct:
b)commencementofconstructionofthebuilding,
c)substantialcompletion ofstructuralframingforeachstorey,ifthebuildingisatypeofbuildingthat iswithinthescopeofDivision8,otherthanPart9,
d)commencementofconstructionof,
- masonryfireplacesandmasonrychimneys,
- factory-builtfireplacesandalliedchimneys,or
- stoves,ranges,spaceheatersandadd-onfurnaces usingsolidfuelsandalliedchimneys,
e)substantialcompletionofinteriorfinishes,
f)substantialcompletion ofheating,ventilating,air-conditioningandair-contaminantextractionequipment,
g)substantialcompletionofexteriorcladding,
h)substantialcompletionofsitegrading,
i)substantial completionofthepooldeckanddressingroomsforapublicpoolorpublicspaandreadinessforinspection oftheemergencystopsystemforapublicpoolorpublicspa,
j)completionandavailabilityofdrawingsofthebuildingasconstructed, and
k)completionofabuildingforwhichanoccupancypermitisrequiredunderArticle1.3.3.4.