  1. Introduction
  2. Ultrasonic Flowmeter Measuring Principle
  3. Thermal Energy Measurement
  4. Measurement Requirements
  5. Description of the Proposed Ultrasonic Flowmeter
  6. Features / Benefits
  7. Technical Data for Instruments Offered
  8. FLUXUS F601PE Portable Thermal Energy Meter
  9. Low flow measurement capability of FLEXIM
  10. Measurement Data
  11. Bill of Materials/Price Proposal
  12. Delivery & Warranty
  13. References

1Introduction

FLEXIM Americas Corporation is a wholly owned subsidiary of FLEXIM GmbH, established in the United States in 2005 as the North & Central American office to manage engineering, development, production sales & marketing and after-sale services to our customer in the region. Since this time FLEXIM Americas has successfully delivered over 8,000 metering solutions for the most demanding of metering conditions including to all of the majors in HVAC energy measurement, gas measurement and is commonly used for billing applications.

2Ultrasonic Flowmeter Measuring Principle

The Transit Time Difference Method

The transmission speed of an ultrasonic signal depends on the flow velocity of the carrier medium; similar to a swimmer swimming against the current, an ultrasonic signal moves slower against the flow direction of the medium than when in flow direction.

For the measurement, two ultrasonic pulses are sent through the medium, one in flow direction, and a second one against it. The transducers are alternatively working as emitter and receiver.

The transit time of the ultrasonic signal propagating in flow direction is shorter than the transit time of the signal propagating against flow direction.

The transit-time difference Δt is measured and allows the determination of the average flow velocity on the propagation path of the ultrasonic signals. A profile correction is performed to obtain the average flow velocity on the cross-section of the pipe, which is proportional to the volume flow.

Since ultrasounds propagate in solids, the transducers can be mounted onto the pipe. Measurement is Non-Invasive and there is no need to cut the pipe or interrupt any process

3Thermal Energy Measurement

FLEXIM’s thermal energy BTU meter is one integrated metering solution. Using precision 1000 ohm RTD’s matched to 0.03degF to measure supply and return temperature, combined with 1% NIST traceable flow measurement, the FLEXIM BTU meter integrates the measurements to a BTU or Ton measurement. Along with Flow, Temperature, BTU’s, Tons, Totals, there is also diagnostic information that provides confidence in the integrity of the measurement.

4Measurement Requirements

The application condition requirements for the BTU Energy Measurement applicationsare:

Application Data – All Sites

Liquid:Chilled WaterTemperature:40oF to 60oF

Hot Water265oF (Max)

Pipe Diameter:2 to 24InchMaterial:Steel

Flow Rates:0 to 20 Ft/SecBi-Direction:No

Outputs:RS-232, 4-20ma, BinaryPower:16hr battery, 120VAC Charger

Mounting Type:Direct/Reflect MountTemp Sensor:Precision 1000ohm

Chain Mount 4-wire Matched .03degF

Summary:2Channel Portable F601 Meter(FLOW & BTU Option)

5Description of the proposed ultrasonic flowmeter

5.1Features/Benefits

The proposed ultrasonic flowmeter has the following features:

  • Calibration –Each transducer pair is factory calibrated and receives a NIST traceable 5-point wet flow calibration to 1% of RATE.
  • Extremely accurate temperature measurement – Matched pair temperature RTD’s to ensure accuracy of ±0.03°F differential measurement with certificate traceable to NIST standards.
  • “Fit for Purpose” FLEXIM Transducers – Factory “matched” and calibrated Stainless Steel Transducers (hermetically sealed) and armored stainless steel cable delivers the robustness required of a portable or permanent device. “Intelligent” design – transducer contains a microchip read by the meter that contains the calibration information. Competing devices are error prone when the transducer type is not input correctly.
  • Transducer Temperature Compensation – The only Clamp-on meter that employs an RTD inside the transducer block as per ASME MFC 5M. A temperature algorithm compensates for calibration shifts due to temperature changes. Without this compensation the accuracy drift due to temperature change will 1% for a 30degF change.
  • Broadened Application Range – FLEXIM incorporates a dynamic power delivery scheme that delivers the power to the transducers required to get the signal through the range of pipe sizes to be measured.
  • Ease of Use – The meter is designed to be intuitive and is very easy to program. Installation of entire meter can be easily accomplished in 4 hours or less.
  • FLEXIM “Flexibility” – All FLEXIM meters can be configured to “adapt” to the application conditions at hand. If the upstream straight run is less than 10 diameters , the users may employ a number of mitigating techniques:
  • ‘Multi-bounce’ transducer mounting allows the meter to average out local disturbances of the flow profile over a longer axial distance on the pipe. An even number of traverses (up to 8) simply cancels all cross-flow, non-axial influences on the flow velocity measured.
  • Proper location of the interrogating sonic beam (in the plane of an upstream elbow for example) assures that the instrument will ‘see’ the fast flowing core of the liquid flow stream.
  • Multi-beam interrogation of the flow stream through the use of two or more transducer pairs to average out asymmetrical flow velocities.
  • Reduced Noise Susceptibility – All FLEXIM flow computers are fully shielded and utilize TRIAX cabling (provides for an additional armored outer shield) to prevent/minimize the influence of external noise sources.
  • Signal Detection – The signal processing of the transmitted signal is NOT based upon a ZERO crossing detection which relies heavily on a “match” between the wall thickness of the pipe and a selected transducer’s operating frequency. Rather FLEXIM employs a signal correlation function in which the entire receive signal is utilized resulting in a more robust signal detection process.
  • Application Guarantee – All meters sold. FLEXIM goes to great lengths to qualify each and every application and as such provides an application guarantee on each meter sold. We will ensure that satisfaction with ALL metering solutions provided by FLEXIM.
  • Support – In addition to FLEXIM’s full-service operation center on Long Island, New York, we have technical personnel on the east, west coasts, Southern and Central States.FLEXIM also provides a “free” telephone hotline for assistance “when you need it”, including after hours 7 days a week till 12AM.
  • Significant Reference Base – FLEXIM has the references that prove FLEXIM to be the premium BTU meter available today.
  • Total Cost of Ownership – No need for recalibration, no wear mechanism, no pressure drop, no additional flanges, valving, by-pass, etc...
  • Proven Reliability – 190 year calculated MTBF

5.2Technical Data of Instrument Offered

5.3FLUXUS F601PE Portable Thermal Energy Meter

FLUXUS F601PEis designed especially for Energy Measurement of chilled and hot water systems. By combining the attributes of FLEXIM’s highly accurate and reliable non-intrusive ultrasonic flow measurement with temperature measurement, and energy calculations, the integrated system is the ideal solution for fiscal energy applications.

Technical Data / F601PE
Measureable flow
velocity: / 0.03 to 115ft/sec
Repeatability: / 0.15 % of reading ±0.01 m/s
Anticipate Accuracy:
Traceable wet flow calibration at factory / .5 to 1.2 % of reading ±0.01 m/s
Temperature Accuracy: / 0.03degF matched 1000ohm RTD’s
Operating temperature: / -20 to +50 °C
Ingress protection: / IP66 / NEMA 4X
Area Certification: / FMC Class I Div 2 (optional)
Power supply: / 16 hour battery
110/220 VAC Charger
Outputs: / RS-232
2 x 4-20 mA active(Optional)
2 x Relay(Optional)
Internal Datalogger

6Low Flow measurement capability of FLEXIM

In thermal energy submetering there are many instances of off-peak very low usage.The meters ability to detect low flow velocities is critical. Not detected these rates become “free energy”.FLEXIM meters are unique in their ability to measure the lowest flow velocities.

Below is a data set from Harvard University. They are supplying chilled water in the month of February to a building that has climate controlled laboratories. The meter is detecting flow velocities from .01ft/sec to .05ft/sec. These velocities are below the detection point of most other types of meters.

7Measurement Data and Download Software

The FLEXIMF601PE meter is equipped with an internal data logger. The internal data logger can store up to 60 days of data at a 10 minute storage intervals. The following data can be stored:

  • Date Time Stamp
  • Instantaneous Volume Flow Rate
  • Volume Flow Total (positive and negative)
  • Instantaneous Energy Rate
  • Energy Total
  • Instantaneous Flow Velocity
  • Supply Temperature
  • Return Temperature
  • Sound Speed Diagnostic – used to verify the accuracy of an installation
  • Signal Strength Diagnostic – used to verify ability of the ultrasonic signal to measure the liquid in question
  • Advanced signal diagnostics used in challenging applications (such as liquids at +400 Degrees F, viscous hydrocarbons, gases, etc…) to detect the presence of air, high turbulence, etc…

Data Sample

The data sample shown here is collected using FLEXIM’s Data Analysis Software- FluxData.

DATE_TIME / VELOC / ENERGY / TOTAL / RETURN / SUPPLY / SSPEED / AMP / FLOW
[fps] / [TON] / [TD] / [ーF] / [ーF] / [m/s] / [%] / [US-gal/min]
12/13/2013 10:41 / 0.463 / 97.497 / 309921.35 / 57.38 / 42.98 / 1453.23 / 57 / 163.18
12/13/2013 10:56 / 0.489 / 107.668 / 309922.31 / 57.92 / 42.98 / 1453.6 / 56 / 172.44
12/13/2013 11:11 / 0.479 / 104.86 / 309923.42 / 57.92 / 42.98 / 1452.4 / 56 / 168.96
12/13/2013 11:26 / 0.469 / 102.031 / 309924.51 / 57.74 / 42.98 / 1453.8 / 56 / 165.49
12/13/2013 11:41 / 0.479 / 106.999 / 309925.61 / 58.1 / 42.98 / 1453.58 / 56 / 168.96

Statistics and Analysis Samples

The diagnostic software has a statistical function which reports Mean, Min, Max, and total values.

Quantity / Unit / Mean / Minimum / Maximum / Minimum Time Stamp / Maximum Time Stamp
Thermal Energy / TON / 102.46 / 1.34 / 361.16 / 29.12.2013 15:56:17 / 06.01.2014 11:11:17
Heat quant. POS / TD / 3.13e+05 / 3.10e+05 / 3.15e+05 / 13.12.2013 10:41:17 / 06.02.2014 10:10:10
Volume flow / GPM / 172.95 / 20.83 / 663.13 / 29.12.2013 15:41:17 / 06.01.2014 11:11:17
Temp. Return / °F / 57.2 / 52.2 / 60.8 / 06.01.2014 10:56:17 / 29.12.2013 16:26:17
Temp. Supply / °F / 43.0 / 40.5 / 57.0 / 17.12.2013 04:11:17 / 29.12.2013 15:56:17
Sound Speed / m/s / 1452.8 / 1439.7 / 1460.9 / 20.12.2013 09:56:17 / 29.12.2013 17:56:17
Signal Amplitude / % / 56.51 / 56.00 / 60.00 / 13.12.2013 10:56:17 / 06.02.2014 10:10:10

FLEXIM SoftwareFlow Trending

8Bill of Materials / Price Proposal

Please issue purchase order(s)
FLEXIM AMERICAS CORPORATION
250-V Executive Drive
Edgewood, NY 11717
Terms: NET 30
FOB: Factory
Freight: Pre-Pay and Add
Validity: 90 Days

9Delivery and Warranty

The terms of delivery shall be within 3-4weeks from the date of order confirmation.

FLEXIM’s guarantee that the design, engineering and the instrument supplied shall be free from defects. All defective material shall be replaced free of charge within 12 months from the date of receipt.

10References

10.1 Universities using FLEXIM

10.2 Some Commercial / Institutional companies using FLEXIM

Page 1 of 15

FLEXIM AMERICAS Corporation

250-V Executive Dr. Edgewood NY 11717 631-492-2300

Empire State Building

Freedom Towers

Barclays Arena

Time Warner Center - NYC

Johnson Controls

Trane

Carrier

Siemens Building Technology

Honeywell

Automated Logic

Utilivisor

Veolia Energy

Calpine - Kennedy Airport

JP Morgan Chase properties

Related properties

Citibank – Boston Properties

Prudential Center

Paramount Bldg – NYC

Morgan Stanley – NYC

Meryl Lynch – NY

1 CMP

Federal Reserve

NASA

CIA – VA

Veterans Hospitals

GSA Buildings

Oakridge National Labs

Brookhaven National Labs

US Treasury

Social Security AdmBldg

US Navy - Pascagoula

Newport News

General Dynamics

US Army offices – Arlington

US Army – CECOM

Buckley AFB

Universal

Disney

HBO

Port Authority of NY

JFK Airport

Atlantic Station Atlanta

Veolia Century City Los Angeles

Miami Art Museum

BoehringerIngelheim

Page 1 of 15

FLEXIM AMERICAS Corporation

250-V Executive Dr. Edgewood NY 11717 631-492-2300