SECTION 10 14 36 - Non-Illuminated Panel Signage
INTERIOR SIGNAGE
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2010 - 2015 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** APCO Signs; interior sign systems.
.
This section is based on the products of APCO Signs, which is located at:
388 Grant St. S.E.
Atlanta, GA 30312
Toll Free Tel: 877-988-2726
Tel: 404-688-9000
Fax: 404-577-3847
Email:request info ()
Web:
[Click Here] for additional information.
Based in Atlanta, GA with sales offices, representatives and dealers throughout the US and around the globe, APCO has been providing innovative sign solutions since 1966. With a solid infrastructure and a proven track record of performance, your APCO signage investment is secured with product availability and service for years to come.
Design and innovation have been at the core of APCO's business since our founding in 1966. It is our passion! With an unprecedented 10 awards for Product Design Excellence as presented by the Industrial Designer's Society of America, APCO continues to offer the broadest range of innovative sign solutions in the industry. All APCO products are built to last, easy to maintain and backed by written warranties.
Nothing happens without good people, and at APCO we have the best in the industry. We do what it takes to ensure complete customer satisfaction, standing by the APCO Golden Rule: If we were the customer, what would we expect?
PART 1 GENERAL
1.1 SECTION INCLUDES
** NOTE TO SPECIFIER ** Delete items below not required for project.
A. Interior integrated modular signage system for directional, control, and informational signage.
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
A. Section 03 30 00 - Cast-in-Place Concrete.
B. Section 04 22 23.29 - Split-Face Concrete Unit Masonry.
C. Section 08 11 13.16 - Custom Hollow Metal Doors and Frames.
D. Section 08 14 23.16 - Plastic-Laminate-Faced Wood Doors.
E. Section 09 21 16.23 - Gypsum Board Shaft Wall Assemblies.
F. Section 09 51 23 - Acoustical Tile Ceilings.
G. Section 09 90 00 - Painting and Coating.
H. Section 09 96 63 - Textured Plastic Coatings.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
A. ANSI A117.1: Providing Accessibility and Usability for Physically Handicap People, 1986 edition.
B. Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).
C. Federal Register Part II, Architectural and Transportation Barriers Compliance Board, 36 CFR Part 1191: Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Amendment to Final Guidelines, September 6, 1991.
D. Federal Register Part III, Department of Justice, Office of the Attorney General, 28 CFR Part 36: Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities, Final Rule, July 26, 1991.
1.4 DEFINITIONS
A. Terms:
1. Braille: Grade 2 Braille including 189 part-word or whole word contractions in addition to Grade 1 Braille 63 characters. Tactile is required whenever braille is required.
2. Non-tactile: Letters and numbers on signs with width-to-height ratio between 3:5 and 1:1 and stroke width ratio between 1:5 and 1:10 using upper case "X" to calculate ratios. Use type styles with medium weight; upper and lower case lettering are permitted; serif typestyles are permitted.
3. Symbols: Symbol itself is not required to be tactile but equivalent verbal description is required both in tactile letters and braille.
4. Tactile: 1/32 inch (0.80 mm) raised capital letters without serifs at least 5/8 inch (16 mm) height and not more than 2 inches (51 mm) height based on upper case "X". Braille is required whenever tactile is required.
1.5 SYSTEM DESCRIPTION
A. Signage under this section is intended to include items for identification, direction, control, and information of building where installed as complete integrated system from a single manufacturer.
B. ADA design requirements:
1. Signage requiring tactile graphics:
a. Wall mounted signs designating permanent rooms and spaces such as, room numbers and restroom, department, office, and fire exit identifications.
b. Individually applied characters are prohibited.
2. Signage not requiring tactile graphics but which are required to comply to other ADA requirements include signs providing direction to or information about function of space such as, directional signs (signs with arrow), informational signs (operating hours, policies, etc.), regulatory signs (no smoking, do not enter), and ceiling and projected wall mount signs.
3. Excluded signage:
a. Exterior signs.
b. Building directories.
c. Menus.
d. Temporary signs, include personnel signs and tenant identification; suite numbers are not considered temporary.
C. ADA performance requirements:
1. Tactile graphics signs mounting requirements:
a. Single doors: Mount 60 inches (1524 mm) to sign centerline above finish floor and on wall adjacent to latch side of door.
b. Openings: Mount 60 inches (1524 mm) to sign centerline above finish floor adjacent opening.
c. No wall space adjacent latch side of door, opening, or double doors: Mount 60 inches (1524 mm) to sign centerline above finish floor on nearest adjacent wall.
D. ADA disclaimer:
1. APCO supports the goal of making facilities accessible and has developed guidelines in an effort to promote voluntary compliance. APCO provides information and guidelines on the Americans with Disabilities Act (ADA) on a voluntary basis, having used extreme care and high standards to assure accuracy in interpretation of the law. However, all information, either written or verbal, is strictly an interpretation and is presented with no warranty either expressed or implied. APCO officers, staff, representatives, and/or consultants assume no legal responsibility for the accuracy of presentations, comments or other ADA information. Neither is liability assumed for the outcome of decisions, contracts, commitments or obligations made on the basis of this information. APCO guidelines are taken from the Department of Justice's final rules implementing Title III of the Americans with Disabilities Act, printed in the Federal Register, 28 CFR, Part 36, 26 July 1991. APCO recommends that anyone affected by ADA obtain a copy of The Americans with Disabilities Act and consult their legal counsel.
1.6 SUBMITTALS
A. Submit under provisions of Section 01 30 00 - Administrative Requirements.
B. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Manufacturer's product literature indicating units and designs selected.
2. Evidence of manufacturer's computerized data retrieval program for tracking of project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product.
3. Preparation instructions and recommendations.
4. Storage and handling requirements and recommendations.
5. Installation methods.
C. Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified. Provide sample in small size sign.
NOTE TO SPECIFIER ** Delete provision not required.
1. Samples will be returned for use in Project.
2. Samples will not be returned for use in Project.
D. Shop Drawings:
1. Indicate materials, sizes, configurations, and applicable substrate mountings.
2. Typography sample for message strips and headers copy.
NOTE TO SPECIFIER ** Option. Delete if not required.
3. Artwork for special graphics.
NOTE TO SPECIFIER ** Option. Delete if not required.
4. Artwork for special headers.
E. Signage Schedule: Complete with location of each sign and the required copy/text.
F. Sign Program Maintenance Plan:
1. Manufacturer shall provide details of software and system of pre-perforated and color coated paper sign inserts allowing client to update and maintain signage graphics in-house.
2. Manufacturer shall provide details of an Online Reordering & Maintenance Application whereby the client can submit sign reorders online and store relevant project information such as sign type drawings, message schedules and product instructions.
G. Contract close out:
1. Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. Maintain computer schedule program for five years for ordering new signage required by Owner.
2. Maintenance data and cleaning requirements for exterior surfaces.
NOTE TO SPECIFIER ** Manufacturer has available software program for personal computers - pc, called "SignWord Pro" enabling end user to produce graphics on insert or sign face. Information in main catalog, Call manufacturer directly at listed telephone number for more info. Delete if not required.
3. Furnish one complete SignWord Pro software package Windows 3.0 or Windows 95 or later, Windows NT 4.0 or later in Owner selected format for PC type computer.
NOTE TO SPECIFIER ** Option. Delete if not required.
1.7 QUALITY ASSURANCE
A. Manufacturer Qualifications:
1. Work required under this section from manufacturer regularly engaged in work of this type and scope for a minimum of 5 years.
2. Maintain computer link between schedule input and computerized typography production.
B. Installer Qualifications: Trained and authorized by manufacturer for installations of required scope and product.
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1. Finish areas designated by Architect.
2. Do not proceed with remaining work until workmanship, graphics, and installation are approved by Architect.
3. Refinish mock-up as required to produce acceptable work.
1.8 DELIVERY, STORAGE, AND HANDLING
A. Package signs to prevent damage during shipment, handling, storage and installation. Products are to remain in their original packaging (unless otherwise specified) until removal is necessary for installation.
B. If installation site is not ready for signage upon delivery, store signs in a dry, air-conditioned environment.
C. Handle signage in accordance with manufacturer's instructions.
D. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
1.9 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.10 SEQUENCING AND SCHEDULING
A. Schedule system installation after room finishes and fixtures have been completed.
1.11 WARRANTY
A. Product Warranty: Provide manufacturer's warranty against defects in materials and workmanship for a period of one year.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: APCO Signs, which is located at: 388 Grant St. S.E.; Atlanta, GA 30312; Toll Free Tel: 877-988-2726; Tel: 404-688-9000; Fax: 404-577-3847; Email:request info (); Web:
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
** NOTE TO SPECIFIER ** Warning: APCO supports the goal of making facilities accessible and has developed guidelines in an effort to promote voluntary compliance. APCO provides information and guidelines on the Americans with Disabilities Act (ADA) on a voluntary basis, having used extreme care and high standards to assure accuracy in interpretation of the law. However, all information, either written or verbal, is strictly an interpretation and is presented with no warranty either expressed or implied. APCO officers, staff, representatives, and/or consultants assume no legal responsibility for the accuracy of presentations, comments or other ADA information. Neither is liability assumed for the outcome of decisions, contracts, commitments or obligations made on the basis of this information. APCO guidelines are taken from the Department of Justice's final rules implementing Title III of the Americans with Disabilities Act, printed in the Federal Register, 28 CFR, Part 36, 26 July 1991. APCO recommends that anyone affected by ADA obtain a copy of The Americans with Disabilities Act and consult their legal counsel.
2.2 ACCEPTABLE PRODUCT
A. Arcadia Curved Face Sign System as manufactured by APCO Signs.
2.3 SYSTEM REQUIREMENTS
A. General:
1. Sign system shall feature solutions for all required sign types, including but not limited to wall mounted personnel signs, work station personnel signs, primary room identification, directories, directional, overhead signs, projection wall signs, free standing signs, restroom signs, regulatory and information signs, stair signs and changeable slide conference room signs.
2. Signs within the system shall feature the same family of components and convey a uniform look throughout.
B. Features:
1. Updatability: Signs shall allow for easy updating of message inserts without the need to replace the entire sign assembly. System shall offer a solution for easy in-house updating of laser printed sign inserts for all sign types, including personnel signs, directories and directional signs.
2. Mounting: Signs shall accommodate installation via fully concealed mechanical fasteners.
C. Graphics and Typography: As selected from manufacturer's standards. Reference sign drawings.
D. Colors and Finishes: As selected from manufacturer's standards. Reference sign drawings.
E. ADA Compliance: Sign system shall comply with all current and applicable ADA regulations, including requirements regarding which sign types require Braille/tactile features, character heights, color contrast and installation locations and mounting heights within the facility.
F. Materials and Construction:
1. Frames/Holders: Curved face sign frames shall be constructed of extruded aluminum, alloy 6063-T6, with minimum 3/4 inch (19 mm) wide contour edge detail. Top/bottom caps shall be aluminum. Plastic caps will not be acceptable. Aluminum extrusions shall contain a minimum of 50% post consumer recycled content and shall be extruded in the USA. Modular sign holders shall accommodate any type of flexible insert material up to .095 inch (2.4 mm) thick.
2. Braille / Tactile Components: PETG-backed photopolymer with raised characters and Braille of minimum 1/32 inch (0.8 mm) depth/thickness. Braille/tactile plaques shall contain a minimum of 40% recycled content.
3. Substrate for Optional Decorative Laminate Backers: Any decorative laminate backers such as Formica or Wilsonart shall be pressure adhered to SiennaCORE, a natural fiber thermoset composite backer with a minimum 50% recycled content and comprised of materials from FSC certified sources. Non-thermoset composite substrates such as PVC or acrylic will not be accepted.
4. Fasteners: Signs shall be able to accommodate fully concealed mechanical fasteners.
NOTE TO SPECIFIER ** Arcadia is a curved-face aluminum sign system featuring unique, contour-shaped edge profiles and available in a wide range of sizes and configurations including wall signs, ceiling signs and free-standing kiosks. The Arcadia system is designed to accommodate a variety of modular sign inserts and displays, including printed paper, injection molded message strips, ADA plaques and more. Arcadia aluminum extrusions contain 50% recycled content and are 100% recyclable. Arcadia is also compatible with APCO's Elements2 range of decorative components and backer shapes.
2.4 SIGN SYSTEM COMPONENTS
NOTE TO SPECIFIER ** If Arcadia system design and specifications are generated by use of APCO's online Design Studio, use sections A-B following and delete sections C-D. If the specifications and design are custom generated, use section C-D following and delete sections A-B.
A. Product: Curved Arcadia Signs as Designed Using APCO Online Design Studio: Reference drawings for location of colors, finishes, sizes and details.
1. Curved aluminum Arcadia Series 1000 sign holders with a wide range of graphics inserts and displays. Reference drawings for colors, finishes, typestyles and other details. Reference sign schedule for exact messages.
2. Curved Aluminum Frame Finish:
NOTE TO SPECIFIER ** Delete finish not required.
a. Satin anodized aluminum finish.
b. Painted Finish: Manufacturer's Standard.
c. Painted Finish: Custom Color.
3. Decorative Divider Bar:
NOTE TO SPECIFIER ** Delete options not required.
a. No divider bar.
b. Polished Acrylic Divider Bar with 1st surface applied color.
c. Polished Acrylic Divider Bar with subsurface applied color. Colors selected from manufacturer's standards. Reference drawings.
4. Core Sign Types: Other sign types, including ceiling and freestanding signs, may be included within the Project. See Signage Schedule and/or drawings for details.
NOTE TO SPECIFIER ** Delete sign type(s) not required. Delete quantity if not required or used.
a. Sign Type - eAR-A, Display Area - 2-3/8 inches h by 6 inches w (60 mm by 152 mm), Description - Personnel Sign-SM, Quantity - __.
b. Sign Type - eAR-A2, 4-3/4 inches h by 8-1/2 inches w (121 mm by 216 mm), Description - Personnel Sign-LG, Quantity - __.
c. Sign Type - eAR-B, Display Area - 5-7/8 inches h by 8-1/2 inches w (149 mm by 216 mm), Description - Room/Dept ID, Quantity - __.
d. Sign Type - eAR-C, Display Area - 3-1/2 inches h by 8-1/2 inches w (89 mm by 216 mm), Description - Mech/Elec/Etc. ID, Quantity - __.
e. Sign Type - eAR-D, Display Area - 8-1/2 inches h by 8-1/2 inches w (216 mm by 165 mm), Description - Conf/Meeting Room, Quantity - __.
f. Sign Type - eAR-E, Display Area - 8-1/2 inches h by 8-1/2 inches w (216 mm by 216), Description - Restroom Sign, Quantity - __.
g. Sign Type - eAR-F, Display Area - 5-7/8 inches h by 5-7/8 inches w (149 mm by 149 mm), Description - Room Number/ADA-SM, Quantity - __.
h. Sign Type - eAR-G, Display Area - 4-3/4 inches h by 8-1/2 inches w (121 mm by 216 mm), Description - In Case of Fire, Quantity - __.
i. Sign Type - eAR-H, Display Area - 8-1/2 inches h by 8-1/2 inches w (216 mm by 216 mm), Description - Stair Sign, Quantity - __.
j. Sign Type - eAR-J, Display Area - 8-1/2 inches h by 8-1/2 inches w (26 mm by 216 mm), Description - Regulatory Sign, Quantity - __.
k. Sign Type - eAR-K, Display Area - 11 inches h by 11 inches w (279 mm by 279 mm), Description - Emergency Plan, Quantity - __.
l. Sign Type - eAR-L, Display Area - 11 inches h by 8-1/2 inches w (279 mm by 216 mm), Description - Meetings/Notices Sign, Quantity - __.
m. Sign Type - eAR-M, Display Area - 17 inches h by 11 inches w (432 mm by 279 mm), Description - Primary Directional, Quantity - __.
n. Sign Type - eAR-M2, Display Area - 11 inches h by 17 inches w (279 mm by 432 mm), Description - Secondary Directional, Quantity - __.
o. Sign Type - eAR-N, Display Area - 22 inches h by 17 inches w (559 mm by 432 mm), Description - Directory, Quantity - __.