SECTION 09 6513.13–RESILIENT BASE

PART 1GENERAL

1.1 SUMMARY

  1. SECTION INCLUDES:
  2. Thermoplastic Rubber (TP) Wall Base
  1. REFERENCES
  2. American Society for Testing and Materials (ASTM):
  3. ASTM D883–Standard Terminology Relating to Plastics
  4. ASTM D1566 - Standard Terminology Relating to Rubber
  5. ASTM D2047 - Standard Test Method for Static Coefficient of Friction of Polish-Coated Flooring Surfaces as Measured by the James Machine.
  6. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
  7. ASTM E662 - Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials.
  8. ASTM F141 - Standard Terminology Relating to Resilient Floor Coverings
  9. ASTM F386 – Standard Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces
  10. ASTM F410 – Standard Test Method for Wear Layer Thickness of Resilient Floor Coverings by Optical Measurement
  11. ASTM F710 - Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring.
  12. ASTM F925 - Standard Test Method for Resistance to Chemicals of Resilient Flooring.
  13. ASTM F1515 - Standard Test Method for Measuring Light Stability of Resilient Flooring by Color Change.
  14. ASTM F1861 - Standard Specification for Resilient Wall Base.
  15. National Fire Protection Association (NFPA)
  16. NFPA 80 – Fire Safety Code.
  17. NFPA 255 - Standard Test Method for Surface Burning Characteristics of Building Materials.
  18. NFPA 286 - Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth.
  19. Resilient Floor Covering Institute (RFCI)
  20. Recommended Work Practices for Removal of Resilient Floor Coverings
  21. SUBMITTALS
  22. General: Submittals must be submitted the under provisions of Section 01300.
  23. Product Data: Manufacturer's published documents on each product to be used, including:
  24. Storage and handling requirements.
  25. Installation instructions and initial maintenance instructions per Technical Data Sheets.
  26. Maintenance and initial finish application instructions per Care & Maintenance documents.
  27. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
  28. Verification Samples: For each finish product specified, two samples representing actual product, color, and patterns.
  29. QUALITY ASSURANCE
  30. Qualifications:
  31. Installer Qualifications: Installer must be a professional, licensed and experienced installer. Installer must have familiarity with both the type, size and format of the product.
  32. Manufacturer’s Qualifications: Manufacturer must provide remote and field technical support and service prior to, during and following installation, as necessary.
  33. Mock-Up:
  34. Provide a mock-up for evaluation of product, surface preparation techniques and installation workmanship.
  35. Do not proceed with remaining work until size, color, thickness, sheen and workmanship are approved by Architect, End-User and/or other stakeholders.
  36. Maintain mock-up area as required in accordance with Care & Maintenance documents to produce acceptable work.
  37. DELIVERY HANDLING & STORAGE
  38. Ordering: Comply with manufacturer’s ordering and lead time requirements to avoid construction delays.
  39. Storage: Store products in climate controlled space(65° F (19° C) - 85° F (30° C) for at least 48 hours prior to installation. Keep products in manufacturer's unopened packaging until ready for installation (except for rolled goods).
  40. Acclimation: Rolled goods must be unrolled and allowed to relax and acclimate for 24 hours prior to installation.
  41. PROJECT CONDITIONS
  42. Environmental Conditions: Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer in accordance with product technical data sheets. Do not install products under environmental conditions outside manufacturer's absolute limits.
  43. WARRANTY
  44. Project Warranty: Refer to Conditions of Contract for project warranty provisions.
  45. Manufacturer’s Commercial Warranty: CapriBase shall be warranted for ten years for material or manufacture defects.

PART 2PRODUCTS

PART 1

PART 2

2.1 PRODUCT MANUFACTURERS

  1. Acceptable Manufacturer:
  2. Capri Collections

209 Bucky Drive

Lititz, PA 17543

P: 800.492.2613
E:

Web:

2.2 SUBSTITUTIONS

  1. ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
  1. Substitutions: Not permitted.
  2. Requests for substitutions will be considered in accordance with provisions of Division 01.
  1. PRODUCT DIMENSIONS
  2. Product: Capri CapriBase Cove and No-Toe Base in coils or sections as manufactured by Capri Collections.
  3. Cove Base Sizes (all sizes nominal):

** NOTE TO SPECIFIER ** Delete size not required.

  1. 2 1/2 inches by 120 feet by 1/8 inch (63.5 mm by 36.5 m by 3.2 mm)
  2. 2 1/2 inches by 4 feet by 1/8 inch (63.5 mm by 1.2 m by 3.2 mm)
  3. 4 inches by 120 feet by 1/8 inch(101.6 mm by 36.5 m by 3.2 mm)
  4. 4 inches by 4 feet by 1/8 inch(101.6mm by 1.2 m by 3.2 mm)
  5. 6 inches by 120 feet by 1/8 inch (152.4 mm by 36.5 m by 3.2 mm)
  6. 6 inches by 4 feet by 1/8 inch (152.4 mm by 1.2 m by 3.2 mm)
  1. No Toe Base Sizes (all sizes nominal):

** NOTE TO SPECIFIER ** Delete size not required.

  1. 2 1/2 inches by 120 feet by 1/8 inch (63.5 mm by 36.5 m by 3.2 mm)
  2. 2 1/2 inches by 4 feet by 1/8 inch (63.5 mm by 1.2 m by 3.2 mm)
  3. 4 inches by 120 feet by 1/8 inch (101.6 mm by 36.5 m by 3.2 mm)
  4. 4 inches by 4 feet by 1/8 inch (101.6 mm by 1.2 m by 3.2 mm)
  1. PRODUCT COLOR

** NOTE TO SPECIFIER **Delete colors not required.

  1. CB01
  2. CB02
  3. CB03
  4. CB04
  5. CB05
  6. CB06
  7. CB07
  8. CB08
  9. CB09
  10. CB10
  11. CB11
  12. CB12
  13. CB13
  14. CB14
  15. CB15
  1. PRODUCT PROFILE

** NOTE TO SPECIFIER ** Delete profiles not required.

  1. Cove
  2. No Toe
  1. PRODUCT Accessories
  2. Matching pre-formed inside and outside corners are available for all colors and sizes.
  3. PHYSICAL CHARACTERISTICS
  4. ASTM F1861 – Standard Specification for Resilient Base:
  5. Classification: Type TP, Group 2, Type A & B
  6. Staining of Adjacent Surfaces Induced by Wall Base: Passes, No Ingredients
  7. Dimensional Stability: Passes, >0.25%
  8. Odor: Passes, No Offensive Odor
  9. ASTM F137 – Passes, ¼” Mandrel
  10. ASTM F1515 – Color Light Stability: Passes, ΔE<8
  11. ASTM F925 – Chemical Resistance:
  12. White vinegar (5% Acetic Acid) - Passes.
  13. Rubbing Alcohol (70% Isopropyl Alcohol) - Passes.
  14. White Mineral Oil (Medicinal Grade) – Passes.
  15. Lye (5% Sodium Hydroxide) - Passes.
  16. Hydrochloric Acid (5% HCI) - Passes.
  17. Sulfuric Acid (5%H2SO4) - Passes.
  18. Household Ammonia (5% Ammonia) - Passes.
  19. Household Bleach (5.25% NaOCl) - Passes.
  20. Olive Oil - Passes.
  21. Kerosene - Passes.
  22. Unleaded Gasoline - Passes.
  23. ASTM E662 (NFPA 258) – Smoke Density: Passes, <450
  24. ASTM E84 (NFPA 286) –Flammability: Class C, 76 - 200
  25. PRODUCT ADHESIVE
  26. Only a compatible, premium wall base adhesive can be used to install Capri Base.

PART 3EXECUTION

** NOTE TO SPECIFIER ** Revise articles below to suit specific project requirements.

PART 1

PART 2

PART 3

3.1 MANUFACTURERS INSTRUCTIONS

  1. Compliance: Review and comply with manufacturer’s technical data sheets, care & maintenance documents, warranty information, technical bulletins and written specifications.
  1. EXAMINATION
  2. Site Verification of Conditions:
  3. Verify substrate conditions, which have been previously installed under other sections, are acceptable for product installation in accordance with manufacturer’s technical data.
  4. Do not begin installation until all substrates have been properly tested and prepared in accordance with Capri Mediterra technical data sheets and applicable ASTM, ACI, NWFA and RFCI standards.
  5. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
  6. PREPARATION
  7. Cleaning: Clean surfaces thoroughly prior to installation.
  8. Substrate Preparation: Prepare surfaces in accordance with substrate preparation requirements publishedin Capri CapriBase technical data sheets.
  9. INSTALLATION
  10. Product Installation: Install materials in accordance with installation instructions published in Capri CapriBasetechnical data sheets.
  11. Traffic Limits: No traffic, cleaning, finishing or placement of furniture should occur in accordance with adhesive traffic limits published in adhesive technical data.
  12. Initial Maintenance: Once adhesive has cured, perform initial maintenance in accordance with initial maintenance instructions published in Capri CapriBasetechnical data sheets and care & maintenance documents.
  13. FINISH APPLICATION
  14. Initial Maintenance: Ensure surfaces have had initial maintenance performed in accordance with initial maintenance instructions published in Capri CapriBase technical data sheets and care & maintenance documents.
  15. Cleaning: Clean surfaces thoroughly prior to finish application.
  16. MAINTENANCE
  17. Daily Maintenance: Long-term care and maintenance must be performed in accordance with daily and routine maintenance instructions published in Capri CapriBase care & maintenance documents.
  18. PROTECTION
  19. Temporary Protection: Protect installed products until completion of project in accordance with material protection requirements published in Capri CapriBase technical data sheets and care & maintenance documents.
  20. Repair: Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION

Capri Collections | 209 Bucky Dr. – Lititz, PA 17543 | P: 800.492.2613 | Revised on 12.17.2018 | Page 1 of 5