POS Interface Configuration Settings

Current Label Settings

Ruby

1.  Data Interface Tab

  1. Record Data Check
  2. Data Source “Serial”
  3. Data Device Set to Desired Serial Port
  4. Data Type “Ruby”
  5. Incoming Automatically Set
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

2.  Mulitprint Printers Tab

Enable for Corresponding Comm Port set by “Data Device” on the “Data Interface” tab

  1. Multiple Printer Enabled Check
  2. Printer 1 Set to Desired Register ID
  3. - drop down list “Journal”
  4. Printer 2 Set to Desired Secondary ID
  5. - drop down list “Receipt”
  6. Printer 3 “None”
  7. - drop down list “None”

Sapphire

Set up Registers 1 through 20 as Sapphire Registers

1. Data Interface Tab

  1. Record Data Check
  2. Data Source “XML”
  3. Data Device “Sapphire”
  4. Data Type “Sapphire”
  5. Incoming Set to Sapphire Register IDs
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

2.  Network System Settings Tab

  1. Sapphire XML Data Path Default: “C:\Sapphire\”

Gilbarco

1.  Data Interface Tab

  1. Record Data Check
  2. Data Source “Serial”
  3. Data Device Set to Desired Serial Port
  4. Data Type “Gilbarco”
  5. Incoming Automatically Set
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

Wayne Nucleus

Wayne Nucleus Data comes in on only one Serial Port. All registers are given an Incoming Data Identification Number to distinguish each Register in the Nucleus.

This number corresponds to the “Incoming” Number set on the Data Interface tab. For Each Register on the Wayne Nucleus System, a corresponding Register Slot must be added with the corresponding Incoming Number (ex: “Register 2” possess “Incoming” number of “2”) All Serial Ports for each register are set to the Serial port that receives the Wayne Nucleus Data.

1.  Data Interface Tab

  1. Record Data Check
  2. Data Source “Serial”
  3. Data Device Set to Desired Serial Port
  4. Data Type “Wayne Nucleus”
  5. Incoming Manually set for each Register
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

Subshop 2000

On Subshop Register, must share folder “Proqueue”. Default location is “C:\sb20\Proqueue\”. This is also the File Path address that is written in the Network / System Settings tab under the Data Transport #.

1.  Data Interface Tab

  1. Record Data Check
  2. Data Source “TCP/IP”
  3. Data Device Set to Desired Data Transport
  4. Data Type “Subshop 2000”
  5. Incoming Manually Set: Data Transport #
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

2.  Network / System Settings Tab

  1. Data Transport #
  2. IP IP Address of Subshop Register
  3. Port # Blank
  4. TCP / UDP settings TCP
  5. Path File Path of folder Proqueue
  6. Reconnect Unchecked
  7. Connect / Listen Default Setting

Autogas

Must share folder on the Autogas system that contains *.jnl files. The File path is written in the Network / System Settings tab under Data Transport #. All Registers are assigned to the same Data Transport. Only one Data Transport is used. When assigning “Incoming” numbers, each Autogas Register is assigned a number corresponding to that Register’s ID number (1-7; if only one register, assign number as “1”) Must also create two (2) ghost Registers in Transearch with Incoming Numbers of “8” and “9”. These ghost registers handle all fuel transactions and are necessary for the Autogas system.

1.  Data Interface Tab

  1. Record Data Check
  2. Data Source “TCP/IP”
  3. Data Device Set to Desired Data Transport
  4. Data Type “Autogas”
  5. Incoming Manually Set: See above
  6. Save As Sets Transearch Register ID
  7. Raw Capture (RC) Gulfcoast Use Only

2.  Network / System Settings Tab

  1. Data Transport #
  2. IP IP address of Autogas System
  3. Port # Blank
  4. TCP / UDP settings TCP
  5. Path File Path of *.jnl folder
  6. Reconnect Unchecked
  7. Connect / Listen Default Setting